Search Search all

Heater Cooler Machine

ClassificationIndustry News 305

Heater Cooler Machine

 

When choosing a suitable heater cooler machine, a variety of factors need to be considered, such as: heating power, cycle pressure, cooling capacity, flow rate, etc. need to be considered. Different working conditions require different models of the corresponding heater cooler machine.

If the heater cooler machine model is not selected properly, it will slightly affect the running time of the equipment and increase the cost of use.

The selection of heater cooler machine needs to consider the following aspects:

1. Determine the basic requirements of the reactor during the temperature control process of the reactor

The temperature control requirements of the user’s reactor are different, the material is different, the quantity is different, the outlet temperature is different, the inlet temperature is different, and the precision requirements are also different, so the model size of the corresponding heater cooler machine is also different. The user needs accurate process data. It is convenient to choose the suitable model.

2. Determine the type of heater cooler machine

The general medium of the cold heater cooler machine includes water, heat transfer oil, ethylene glycol aqueous solution, antifreeze, etc. According to the different temperature requirements of the reaction kettle, the reaction medium type of the heater cooler machine can be determined. According to your own site conditions, choose the type of air cooling or water cooling, and make supporting preparations. In some special environments, the heater cooler machine can also customize the isolation explosion-proof type according to the corresponding requirements, and have the corresponding explosion-proof grade. Of course, the price will be one more explosion-proof fee than the ordinary one.

3. Determine the parameter configuration of the heater cooler machine

After the user provides the manufacturer with accurate working condition data, the manufacturer will provide the corresponding cooling and heating temperature control scheme after calculation. In the scheme, there will be the selected heater cooler machine model and parameter configuration. The user can see the details of each accessory in the parameter configuration. Brand, generally speaking, for the operation stability of the heater cooler machine, some brand manufacturers’ accessories are selected. Some accessories have multiple brands to choose from. If users have needs, they can contact and modify them. They are generally standard, but they can also be customized.

There are many factors to be considered in the selection of heater cooler machine. The location and environment of the equipment also need to consider the size and size, and reserve the corresponding ventilation position for placing the equipment.

 

Customized Solutions For Your Business


Cooling and Heating Systems (SUNDI series)

Temperature Control Range: -120°C to +350°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Temperature range -40 ~ +200°C series -10 ~ +200°C series -25 ~ +200°C series -25 ~ +300°C series -45 ~ +250°C series -45 ~ +300°C series -60 ~ +250°C series -60 ~ +300°C series -70 ~ +250°C series -80 ~ +250°C series-90 ~ +250°C series -100 ~ +100°C series -25 ~ +200°C one machine for two reactors -40 ~ +200°C one machine for two reactors
Cooling Capacityup to 3kWup to 15kWup to 200kWup to 200kWup to 200kWup to 25kWup to 60kWup to 25kWup to 15kWup to 80kWup to 80kWup to 80kWup to 10*2kWup to 10*2kW

 


Cooling and Heating Systems (WTD series)

(Micro channel / tube reactors specialized)

Temperature Control Range: -70°C to +300°C

Specialized design for micro channel (small liquid holding capacity, strong heat exchange capacity, circulation system high pressure drop)

 

Temperature range -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Cooling Capacityup to 7.5kWup to 5.5kWup to 50kW

 


Cooling and Heating Systems (TES series)

Temperature Control Range: -85°C ~ +250°C

Temp Control Accuracy: ± 0.3°C

 

 

Temperature range -45°C ~ +250°C series -85°C ~ +200°C series -60°C ~ +200°C series
Cooling Capacityup to 25kWup to 25kWup to 60kW

 


Cooling and Heating Machines (LTS series)

Temperature Control Range: -80°C to +80°C

It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.

 

 

Temperature range -20°C ~ +80°C series -45°C ~ +80°C series -60°C ~ +80°C series -80°C ~ +80°C series
Flow Control7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min

 


Cooling and Heating Circulators

Temperature Control Range: -45°C to +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Temperature range -25°C ~ +200°C series -45°C ~ +250°C series
Cooling Capacityup to 15kWup to 15kW

 


Heating Circulators

Temperature Control Range: +50°C to +300°C

Note: UC series can control the temperature of heat transfer medium. UST series can not only control the temperature of the heat transfer medium, but also control the temperature of the reaction material.

Temperature range +50°C ~ +200°C  (UC series) +50°C ~ +300°C  (UC series) +50°C ~ +300°C  (UST series)
Heating Capacityup to 38kWup to 200kWup to 95kW

 


TCU Multi-reactors Temperature Control System

Temperature Control Range: -120°C to +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Temperature range -45°C ~ +250°C series -120°C ~ +250°C seriesCustomized Temperature Control SystemRT+10°C ~ +135°C
Heating Capacityup to 80kWup to 80kWCustomup to 300kW

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Latest News

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller