Heater Cooler Machine
When choosing a suitable heater cooler machine, a variety of factors need to be considered, such as: heating power, cycle pressure, cooling capacity, flow rate, etc. need to be considered. Different working conditions require different models of the corresponding heater cooler machine.
If the heater cooler machine model is not selected properly, it will slightly affect the running time of the equipment and increase the cost of use.
The selection of heater cooler machine needs to consider the following aspects:
1. Determine the basic requirements of the reactor during the temperature control process of the reactor
The temperature control requirements of the user’s reactor are different, the material is different, the quantity is different, the outlet temperature is different, the inlet temperature is different, and the precision requirements are also different, so the model size of the corresponding heater cooler machine is also different. The user needs accurate process data. It is convenient to choose the suitable model.
2. Determine the type of heater cooler machine
The general medium of the cold heater cooler machine includes water, heat transfer oil, ethylene glycol aqueous solution, antifreeze, etc. According to the different temperature requirements of the reaction kettle, the reaction medium type of the heater cooler machine can be determined. According to your own site conditions, choose the type of air cooling or water cooling, and make supporting preparations. In some special environments, the heater cooler machine can also customize the isolation explosion-proof type according to the corresponding requirements, and have the corresponding explosion-proof grade. Of course, the price will be one more explosion-proof fee than the ordinary one.
3. Determine the parameter configuration of the heater cooler machine
After the user provides the manufacturer with accurate working condition data, the manufacturer will provide the corresponding cooling and heating temperature control scheme after calculation. In the scheme, there will be the selected heater cooler machine model and parameter configuration. The user can see the details of each accessory in the parameter configuration. Brand, generally speaking, for the operation stability of the heater cooler machine, some brand manufacturers’ accessories are selected. Some accessories have multiple brands to choose from. If users have needs, they can contact and modify them. They are generally standard, but they can also be customized.
There are many factors to be considered in the selection of heater cooler machine. The location and environment of the equipment also need to consider the size and size, and reserve the corresponding ventilation position for placing the equipment.
Customized Solutions For Your Business
Cooling and Heating Systems (SUNDI series)
Temperature Control Range: -120°C to +350°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperature range | -40 ~ +200°C series | -10 ~ +200°C series | -25 ~ +200°C series | -25 ~ +300°C series | -45 ~ +250°C series | -45 ~ +300°C series | -60 ~ +250°C series | -60 ~ +300°C series | -70 ~ +250°C series | -80 ~ +250°C series | -90 ~ +250°C series | -100 ~ +100°C series | -25 ~ +200°C one machine for two reactors | -40 ~ +200°C one machine for two reactors |
Cooling Capacity | up to 3kW | up to 15kW | up to 200kW | up to 200kW | up to 200kW | up to 25kW | up to 60kW | up to 25kW | up to 15kW | up to 80kW | up to 80kW | up to 80kW | up to 10*2kW | up to 10*2kW |
Cooling and Heating Systems (WTD series)
(Micro channel / tube reactors specialized)
Temperature Control Range: -70°C to +300°C
Specialized design for micro channel (small liquid holding capacity, strong heat exchange capacity, circulation system high pressure drop)
Temperature range | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C |
Cooling Capacity | up to 7.5kW | up to 5.5kW | up to 50kW |
Cooling and Heating Systems (TES series)
Temperature Control Range: -85°C ~ +250°C
Temp Control Accuracy: ± 0.3°C
Temperature range | -45°C ~ +250°C series | -85°C ~ +200°C series | -60°C ~ +200°C series |
Cooling Capacity | up to 25kW | up to 25kW | up to 60kW |
Cooling and Heating Machines (LTS series)
Temperature Control Range: -80°C to +80°C
It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.
Temperature range | -20°C ~ +80°C series | -45°C ~ +80°C series | -60°C ~ +80°C series | -80°C ~ +80°C series |
Flow Control | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min |
Cooling and Heating Circulators
Temperature Control Range: -45°C to +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperature range | -25°C ~ +200°C series | -45°C ~ +250°C series |
Cooling Capacity | up to 15kW | up to 15kW |
Heating Circulators
Temperature Control Range: +50°C to +300°C
Note: UC series can control the temperature of heat transfer medium. UST series can not only control the temperature of the heat transfer medium, but also control the temperature of the reaction material.
Temperature range | +50°C ~ +200°C (UC series) | +50°C ~ +300°C (UC series) | +50°C ~ +300°C (UST series) |
Heating Capacity | up to 38kW | up to 200kW | up to 95kW |
TCU Multi-reactors Temperature Control System
Temperature Control Range: -120°C to +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperature range | -45°C ~ +250°C series | -120°C ~ +250°C series | Customized Temperature Control System | RT+10°C ~ +135°C |
Heating Capacity | up to 80kW | up to 80kW | Custom | up to 300kW |