Search Search all

Heating and Cooling Circulation Device for Jacketed Reactors

ClassificationIndustry News 122 0

Heating and Cooling Circulation Device for Jacketed Reactors

 

When used in jacketed reactors, heating and cooling circulation device can provide accurate and wide-range temperature control to meet the needs of hot and cold changes during the reaction process.

Advantages of heating and cooling circulation device:

1. Flexible temperature control: It integrates heating and cooling functions, and can quickly and accurately adjust the temperature in the reactor within a large temperature range to adapt to complex reaction conditions.

2. Efficient heat exchange: Through the jacket design, the circulating medium (usually heat transfer oil or water) circulates on the outer wall of the reactor to achieve efficient heat transfer and reduce energy loss.

3. Temperature uniformity: The circulation system ensures uniform temperature in the reactor, avoids local overheating or overcooling, and improves the uniformity of the reaction and product quality.

4. Safety and stability: It is equipped with various safety protection devices, such as over-temperature alarm, pressure control, etc., to ensure safe and reliable operation.

5. Automatic control: Modern systems are mostly integrated with automatic control systems, which can preset temperature curves and automatically adjust heating or cooling rates, facilitating the management of complex experimental processes.

 

Heating and Cooling Circulation Device for Jacketed Reactors

 

Application examples of heating and cooling circulation device:

Synthesis of fine chemicals: In complex organic synthesis that requires precise temperature control, to meet the reaction temperature requirements at different stages.

Pharmaceutical process: In the synthesis of pharmaceutical intermediates or active ingredients, ensure that the reaction conditions strictly meet the requirements to ensure product quality and yield.

Polymerization reaction: When synthesizing polymer materials, it is necessary to switch heating and cooling at different stages to control the polymerization rate and molecular structure.

Biochemical engineering: In enzyme-catalyzed reactions or microbial cultures, maintain a suitable temperature environment to promote the development of biological activity.

Material science research: In the synthesis and characterization of new materials, control reaction conditions and study the effect of temperature on material properties.

 


 

We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.

We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.

request

Email: lilia@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 

scan

 

1.Cooling and Heating Systems


Cooling and Heating Systems (SUNDI series)

(Custom Designs)

  • Temperature range: -120℃ ~ +350℃
  • High-precision, intelligent temperature control
  • Cooling capacity: 0.5kW ~ 1200kW
  • Fully closed system to extend the service life of thermal fluid
  • Each device is load tested for more than 12 hours

 

Temperature range -10 ~ +150°C series -25 ~ +200°C series -25 ~ +300°C series -45 ~ +250°C series -45 ~ +300°C series -60 ~ +250°C series -60 ~ +300°C series -70 ~ +250°C series -80 ~ +250°C series-90 ~ +250°C series -100 ~ +100°C series
Cooling Capacity1.5 ~ 15kW1 ~ 200kW1 ~ 200kW0.45 ~ 200kW0.9 ~ 25kW0.25 ~ 60kW0.75 ~ 25kW0.4 ~ 15kW0.3 ~ 80kW0.2 ~ 80kW0.45 ~ 80kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


Cooling and Heating Circulators

(Custom Designs)

  • Temperature range: -45℃ ~ +250℃
  • Emerson Copeland compressor, reliable quality
  • Self-diagnosis function, multiple safety protection devices
  • Fully closed system to extend the service life of thermal fluid
  • Each device is load tested for more than 12 hours

 

Temperature range -25°C ~ +200°C series -45°C ~ +250°C series
Cooling Capacity1 ~ 15kW0.25 ~ 15kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


Cooling and Heating Systems (WTD series)

(Custom Designs)

  • (Micro channel / tube reactors specialized)
  • Temperature range: -70℃ ~ +300℃
  • High-performance circulation pump, more stable temperature control effect
  • Wide temperature range to meet the needs of more industries
  • Each device is load tested for more than 12 hours

 

Temperature range -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Cooling Capacity1.1 ~ 7.5kW1.5 ~ 5.5kW11 ~ 50kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


TCU Multi-reactors Temperature Control System

(Custom Designs)

  • Temperature range: -120℃ ~ +250℃
  • Sealed, repeatable temperature control
  • Built-in electric heating thermal oil auxiliary system
  • Add cold and heat source heat exchange modules according to needs
  • Each device is load tested for more than 12 hours

 

Temperature range -45°C ~ +250°C series -120°C ~ +250°C seriesCustomized Temperature Control SystemRT+10°C ~ +135°C
Heating Capacity25 ~ 80kW25 ~ 80kWCustom25 ~ 300kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 

 

2.Cooling Chillers


low temperature chiller

Low Temperature/Cryogenic Chillers (Water Cooled)

(Custom Designs)

  • Temperature range: -150℃ ~ -5℃
  • International brand compressor, high cooling efficiency
  • Secondary subcooling technology, fast cooling speed
  • Automated control and operation, efficient and energy-saving
  • Each device is load tested for more than 12 hours

Six product series

Temperature range -25°C ~ -5°C -45°C ~ -10°C -60°C ~ -10°C -80°C ~ -30°C-110°C ~ -50°C -150°C ~ -110°C
Cooling Capacity12kW…360kW6kW…180kW6kW…180kW4kW…180kW2kW…120kW2.5kW…11kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


recirculating chiller

Recirculating Chiller/Refrigerated Circulator (Air Cooled)

(Custom Designs)

  • Temperature range: -120℃ ~ +30℃
  • International brand compressor, cascade refrigeration technology
  • Use ethylene glycol or a mixture of ethylene glycol and water
  • Fully sealed design to ensure the purity of the medium
  • Each device is load tested for more than 12 hours

Five product series

Temperature range -25°C ~ +30°C -45°C ~ +30°C -60°C ~ -20°C -80°C ~ -20°C -120°C ~ -70°C
Cooling Capacity0.8kW…30kW0.75kW…12kW0.4kW…6kW0.2kW…6kW0.3kW…5kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


 

Precision Chillers / Small ChillersSmall Chillers / Mini Chillers

(Custom Designs)

  • Temperature range: -18℃ ~ +35℃
  • International brand compressor, stable performance
  • Microcomputer controller, adjustment unit 0.1℃
  • Energy saving, high temperature control accuracy
  • Each device is load tested for more than 12 hours

Two product series

Temperature range -18°C ~ +30°C +5°C ~ +35°C
Cooling Capacity0.35 ~ 0.9kW1.8kW…50kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


SEMICONDUCTOR CHILLER

 

High Temperature Chillers

(Custom Designs)

  • Temperature range: -100℃ ~ +80℃
  • International brand compressors and other accessories
  • Fully sealed design to ensure the purity of the medium
  • PLC programmable controller
  • Each device is load tested for more than 12 hours

Five product series

Temperature range +5°C ~ +40°C -25°C ~ +40°C -45°C ~ +40°C -80°C ~ +80°C -100°C ~ +80°C
Cooling Capacity6kW…40kW2kW…15kW1kW…8kW0.kW…3kW1.5kW…3kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Latest News
Request a Quote
Name
Email Address
Phone
Company
Message

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller