Heating and Cooling Circulation System for Jacketed Reactor
When used in jacketed reactors, heating and cooling circulation systems (also called heat exchange systems) are key equipment to ensure that chemical reactions are carried out at a constant and controllable temperature. These systems are designed specifically for jacket structures and can efficiently transfer heat to or remove heat from the reaction medium to achieve the desired heating or cooling effect.
The following points are the key points to consider when selecting a heating and cooling circulation system for jacketed reactors:
1. Compatibility and installation: Make sure the system matches the size and interface of your jacketed reactor for easy installation and good sealing to prevent leakage.
2. Temperature control accuracy and stability: Choose a system with high-precision temperature control capability (±0.1~0.5℃) to keep the reaction temperature stable and improve the consistency of experimental or production results.
3. Power and efficiency: According to the reactor volume and the required temperature change rate, select a heating and cooling unit with appropriate power, while considering the system’s energy efficiency ratio to reduce operating costs.
4. Safety: The system should be equipped with multiple safety measures such as over-temperature protection and pressure safety valve to ensure safe operation.
5. Control system: Programmable controller (PLC) and user-friendly interface can easily preset temperature programs, support remote monitoring and data logging, and improve the level of automation.
6. Easy maintenance: Consider the ease of maintenance of the system, such as whether it is easy to clean and replace parts, etc., to reduce downtime.
If you can provide the specific specifications of the jacketed reactor (such as volume, material properties, target application, etc.), I can further recommend a suitable heating and cooling circulation system model or provide customized suggestions for you.
We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.
We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.
Email: lilia@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
1.Cooling and Heating Systems
Cooling and Heating Systems (SUNDI series)
- Temperature range: -120℃ ~ +350℃
- High-precision, intelligent temperature control
- Cooling capacity: 0.5kW ~ 1200kW
- Fully closed system to extend the service life of thermal fluid
- Each device is load tested for more than 12 hours
Temperature range | -10 ~ +150°C series | -25 ~ +200°C series | -25 ~ +300°C series | -45 ~ +250°C series | -45 ~ +300°C series | -60 ~ +250°C series | -60 ~ +300°C series | -70 ~ +250°C series | -80 ~ +250°C series | -90 ~ +250°C series | -100 ~ +100°C series | ||
Cooling Capacity | 1.5 ~ 15kW | 1 ~ 200kW | 1 ~ 200kW | 0.45 ~ 200kW | 0.9 ~ 25kW | 0.25 ~ 60kW | 0.75 ~ 25kW | 0.4 ~ 15kW | 0.3 ~ 80kW | 0.2 ~ 80kW | 0.45 ~ 80kW | ||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Cooling and Heating Circulators
- Temperature range: -45℃ ~ +250℃
- Emerson Copeland compressor, reliable quality
- Self-diagnosis function, multiple safety protection devices
- Fully closed system to extend the service life of thermal fluid
- Each device is load tested for more than 12 hours
Temperature range | -25°C ~ +200°C series | -45°C ~ +250°C series | |||||||
Cooling Capacity | 1 ~ 15kW | 0.25 ~ 15kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Cooling and Heating Systems (WTD series)
- (Micro channel / tube reactors specialized)
- Temperature range: -70℃ ~ +300℃
- High-performance circulation pump, more stable temperature control effect
- Wide temperature range to meet the needs of more industries
- Each device is load tested for more than 12 hours
Temperature range | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C | ||||||
Cooling Capacity | 1.1 ~ 7.5kW | 1.5 ~ 5.5kW | 11 ~ 50kW | ||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
TCU Multi-reactors Temperature Control System
- Temperature range: -120℃ ~ +250℃
- Sealed, repeatable temperature control
- Built-in electric heating thermal oil auxiliary system
- Add cold and heat source heat exchange modules according to needs
- Each device is load tested for more than 12 hours
Temperature range | -45°C ~ +250°C series | -120°C ~ +250°C series | Customized Temperature Control System | RT+10°C ~ +135°C | |||||
Heating Capacity | 25 ~ 80kW | 25 ~ 80kW | Custom | 25 ~ 300kW | |||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
2.Cooling Chillers
Low Temperature/Cryogenic Chillers (Water Cooled)
- Temperature range: -150℃ ~ -5℃
- International brand compressor, high cooling efficiency
- Secondary subcooling technology, fast cooling speed
- Automated control and operation, efficient and energy-saving
- Each device is load tested for more than 12 hours
Six product series
Temperature range | -25°C ~ -5°C | -45°C ~ -10°C | -60°C ~ -10°C | -80°C ~ -30°C | -110°C ~ -50°C | -150°C ~ -110°C | |||
Cooling Capacity | 12kW…360kW | 6kW…180kW | 6kW…180kW | 4kW…180kW | 2kW…120kW | 2.5kW…11kW | |||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Recirculating Chiller/Refrigerated Circulator (Air Cooled)
- Temperature range: -120℃ ~ +30℃
- International brand compressor, cascade refrigeration technology
- Use ethylene glycol or a mixture of ethylene glycol and water
- Fully sealed design to ensure the purity of the medium
- Each device is load tested for more than 12 hours
Five product series
Temperature range | -25°C ~ +30°C | -45°C ~ +30°C | -60°C ~ -20°C | -80°C ~ -20°C | -120°C ~ -70°C | ||||
Cooling Capacity | 0.8kW…30kW | 0.75kW…12kW | 0.4kW…6kW | 0.2kW…6kW | 0.3kW…5kW | ||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Small Chillers / Mini Chillers
- Temperature range: -18℃ ~ +35℃
- International brand compressor, stable performance
- Microcomputer controller, adjustment unit 0.1℃
- Energy saving, high temperature control accuracy
- Each device is load tested for more than 12 hours
Two product series
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C | |||||||
Cooling Capacity | 0.35 ~ 0.9kW | 1.8kW…50kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
High Temperature Chillers
- Temperature range: -100℃ ~ +80℃
- International brand compressors and other accessories
- Fully sealed design to ensure the purity of the medium
- PLC programmable controller
- Each device is load tested for more than 12 hours
Five product series
Temperature range | +5°C ~ +40°C | -25°C ~ +40°C | -45°C ~ +40°C | -80°C ~ +80°C | -100°C ~ +80°C | ||||
Cooling Capacity | 6kW…40kW | 2kW…15kW | 1kW…8kW | 0.kW…3kW | 1.5kW…3kW | ||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |