Search Search all

Heating and Cooling Circulation System for Jacketed Reactor

ClassificationIndustry News 117 0

Heating and Cooling Circulation System for Jacketed Reactor

 

When used in jacketed reactors, heating and cooling circulation systems (also called heat exchange systems) are key equipment to ensure that chemical reactions are carried out at a constant and controllable temperature. These systems are designed specifically for jacket structures and can efficiently transfer heat to or remove heat from the reaction medium to achieve the desired heating or cooling effect.

 

Heating and Cooling Circulation System for Jacketed Reactor

 

The following points are the key points to consider when selecting a heating and cooling circulation system for jacketed reactors:

1. Compatibility and installation: Make sure the system matches the size and interface of your jacketed reactor for easy installation and good sealing to prevent leakage.

2. Temperature control accuracy and stability: Choose a system with high-precision temperature control capability (±0.1~0.5℃) to keep the reaction temperature stable and improve the consistency of experimental or production results.

3. Power and efficiency: According to the reactor volume and the required temperature change rate, select a heating and cooling unit with appropriate power, while considering the system’s energy efficiency ratio to reduce operating costs.

4. Safety: The system should be equipped with multiple safety measures such as over-temperature protection and pressure safety valve to ensure safe operation.

5. Control system: Programmable controller (PLC) and user-friendly interface can easily preset temperature programs, support remote monitoring and data logging, and improve the level of automation.

6. Easy maintenance: Consider the ease of maintenance of the system, such as whether it is easy to clean and replace parts, etc., to reduce downtime.

If you can provide the specific specifications of the jacketed reactor (such as volume, material properties, target application, etc.), I can further recommend a suitable heating and cooling circulation system model or provide customized suggestions for you.

 


 

We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.

We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.

request

Email: lilia@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 

scan

 

1.Cooling and Heating Systems


Cooling and Heating Systems (SUNDI series)

(Custom Designs)

  • Temperature range: -120℃ ~ +350℃
  • High-precision, intelligent temperature control
  • Cooling capacity: 0.5kW ~ 1200kW
  • Fully closed system to extend the service life of thermal fluid
  • Each device is load tested for more than 12 hours

 

Temperature range -10 ~ +150°C series -25 ~ +200°C series -25 ~ +300°C series -45 ~ +250°C series -45 ~ +300°C series -60 ~ +250°C series -60 ~ +300°C series -70 ~ +250°C series -80 ~ +250°C series-90 ~ +250°C series -100 ~ +100°C series
Cooling Capacity1.5 ~ 15kW1 ~ 200kW1 ~ 200kW0.45 ~ 200kW0.9 ~ 25kW0.25 ~ 60kW0.75 ~ 25kW0.4 ~ 15kW0.3 ~ 80kW0.2 ~ 80kW0.45 ~ 80kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


Cooling and Heating Circulators

(Custom Designs)

  • Temperature range: -45℃ ~ +250℃
  • Emerson Copeland compressor, reliable quality
  • Self-diagnosis function, multiple safety protection devices
  • Fully closed system to extend the service life of thermal fluid
  • Each device is load tested for more than 12 hours

 

Temperature range -25°C ~ +200°C series -45°C ~ +250°C series
Cooling Capacity1 ~ 15kW0.25 ~ 15kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


Cooling and Heating Systems (WTD series)

(Custom Designs)

  • (Micro channel / tube reactors specialized)
  • Temperature range: -70℃ ~ +300℃
  • High-performance circulation pump, more stable temperature control effect
  • Wide temperature range to meet the needs of more industries
  • Each device is load tested for more than 12 hours

 

Temperature range -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Cooling Capacity1.1 ~ 7.5kW1.5 ~ 5.5kW11 ~ 50kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


TCU Multi-reactors Temperature Control System

(Custom Designs)

  • Temperature range: -120℃ ~ +250℃
  • Sealed, repeatable temperature control
  • Built-in electric heating thermal oil auxiliary system
  • Add cold and heat source heat exchange modules according to needs
  • Each device is load tested for more than 12 hours

 

Temperature range -45°C ~ +250°C series -120°C ~ +250°C seriesCustomized Temperature Control SystemRT+10°C ~ +135°C
Heating Capacity25 ~ 80kW25 ~ 80kWCustom25 ~ 300kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 

 

2.Cooling Chillers


low temperature chiller

Low Temperature/Cryogenic Chillers (Water Cooled)

(Custom Designs)

  • Temperature range: -150℃ ~ -5℃
  • International brand compressor, high cooling efficiency
  • Secondary subcooling technology, fast cooling speed
  • Automated control and operation, efficient and energy-saving
  • Each device is load tested for more than 12 hours

Six product series

Temperature range -25°C ~ -5°C -45°C ~ -10°C -60°C ~ -10°C -80°C ~ -30°C-110°C ~ -50°C -150°C ~ -110°C
Cooling Capacity12kW…360kW6kW…180kW6kW…180kW4kW…180kW2kW…120kW2.5kW…11kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


recirculating chiller

Recirculating Chiller/Refrigerated Circulator (Air Cooled)

(Custom Designs)

  • Temperature range: -120℃ ~ +30℃
  • International brand compressor, cascade refrigeration technology
  • Use ethylene glycol or a mixture of ethylene glycol and water
  • Fully sealed design to ensure the purity of the medium
  • Each device is load tested for more than 12 hours

Five product series

Temperature range -25°C ~ +30°C -45°C ~ +30°C -60°C ~ -20°C -80°C ~ -20°C -120°C ~ -70°C
Cooling Capacity0.8kW…30kW0.75kW…12kW0.4kW…6kW0.2kW…6kW0.3kW…5kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


 

Precision Chillers / Small ChillersSmall Chillers / Mini Chillers

(Custom Designs)

  • Temperature range: -18℃ ~ +35℃
  • International brand compressor, stable performance
  • Microcomputer controller, adjustment unit 0.1℃
  • Energy saving, high temperature control accuracy
  • Each device is load tested for more than 12 hours

Two product series

Temperature range -18°C ~ +30°C +5°C ~ +35°C
Cooling Capacity0.35 ~ 0.9kW1.8kW…50kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


SEMICONDUCTOR CHILLER

 

High Temperature Chillers

(Custom Designs)

  • Temperature range: -100℃ ~ +80℃
  • International brand compressors and other accessories
  • Fully sealed design to ensure the purity of the medium
  • PLC programmable controller
  • Each device is load tested for more than 12 hours

Five product series

Temperature range +5°C ~ +40°C -25°C ~ +40°C -45°C ~ +40°C -80°C ~ +80°C -100°C ~ +80°C
Cooling Capacity6kW…40kW2kW…15kW1kW…8kW0.kW…3kW1.5kW…3kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Latest News
Request a Quote
Name
Email Address
Phone
Company
Message

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller