Heating Recovery Chiller
The heating recovery chiller is an intelligent temperature control integrated machine for fluid temperature control. It is also called high and low temperature integrated machine, refrigeration and heating integrated machine, etc. on the market. It is often used with a reaction kettle for cooling, heating, and temperature control. It is a centralized cooling and heating Integrated temperature control equipment, the heat transfer medium is water or heat transfer oil, and the cooling medium is ethylene glycol, water, etc.
First, the working principle of heating recovery chiller:
The heating recovery chiller is an auxiliary machine, which is used with various instruments and equipment. The inlet and outlet of the heating equipment are connected to the client equipment for temperature control. There is a heat exchanger on the side of the cooling system to perform indirect heat exchange for the heating equipment to achieve the purpose of cooling down, and the heating medium cools down. Then exchange heat with the client to start to lower the temperature of the client device, which is a cycle. The heating recovery chiller is equipped with a computer control panel, which is convenient and simple to operate, and has high temperature control accuracy.
Second, the selection considerations for heating recovery chiller:
When choosing a heating recovery chiller, customers and friends must be very clear about their own process requirements. The temperature range of the equipment is different. For example, the equipment above normal temperature is different from the heating recovery chiller involving sub-zero temperature. The temperature can be divided into low temperature and ultra-low temperature, and the temperature above zero can be divided into high temperature and high temperature. In this way, there are many combinations of temperature ranges for high and low temperature thermostats. Different combinations have different technical requirements. This requires professional technical services.
Secondly, the heating recovery chiller can be distinguished from the different media. It can be oil equipment, water equipment, or mixed equipment. Different media have different design ideas.
Dynamic Temperature Control Systems (Support Customization)
Cooling and Heating Systems (SUNDI series) (Custom Designs)
Temperature Control Range: -120°C to +350°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperature range | -10 ~ +150°C series | -25 ~ +200°C series | -25 ~ +300°C series | -45 ~ +250°C series | -45 ~ +300°C series | -60 ~ +250°C series | -60 ~ +300°C series | -70 ~ +250°C series | -80 ~ +250°C series | -90 ~ +250°C series | -100 ~ +100°C series | -25 ~ +200°C one machine for two reactors | -40 ~ +200°C one machine for two reactors |
Cooling Capacity | 1.5 ~ 15kW | 1 ~ 200kW | 1 ~ 200kW | 0.45 ~ 200kW | 0.9 ~ 25kW | 0.25 ~ 60kW | 0.75 ~ 25kW | 0.4 ~ 15kW | 0.3 ~ 80kW | 0.2 ~ 80kW | 0.45 ~ 80kW | up to 10*2kW | up to 10*2kW |
Cooling and Heating Systems (WTD series) (Custom Designs)
(Micro channel / tube reactors specialized)
Temperature Control Range: -70°C to +300°C
Specialized design for micro channel (small liquid holding capacity, strong heat exchange capacity, circulation system high pressure drop)
Temperature range | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C |
Cooling Capacity | 1.1 ~ 7.5kW | 1.5 ~ 5.5kW | 11 ~ 50kW |
Cooling and Heating Systems (TES series) (Custom Designs)
Temperature Control Range: -85°C ~ +250°C
Temp Control Accuracy: ± 0.3°C
Temperature range | -45°C ~ +250°C series | -85°C ~ +200°C series | -60°C ~ +200°C series |
Cooling Capacity | 0.3 ~ 25kW | 0.25 ~ 25kW | 3 ~ 60kW |
Cooling and Heating Machines (LTS series) (Custom Designs)
Temperature Control Range: -80°C to +80°C
It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.
Temperature range | -20°C ~ +80°C series | -45°C ~ +80°C series | -60°C ~ +80°C series | -80°C ~ +80°C series |
Flow Control | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min |
Cooling and Heating Circulators (Custom Designs)
Temperature Control Range: -45°C to +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperature range | -25°C ~ +200°C series | -45°C ~ +250°C series |
Cooling Capacity | 1 ~ 15kW | 0.25 ~ 15kW |
Heating Circulators (Custom Designs)
Temperature Control Range: +50°C to +300°C
Note: UC series can control the temperature of heat transfer medium. UST series can not only control the temperature of the heat transfer medium, but also control the temperature of the reaction material.
Temperature range | +50°C ~ +170°C (UC series) | +50°C ~ +300°C (UC series) | +50°C ~ +300°C (UST series) |
Heating Capacity | 5.5 ~ 15kW | 3.5 ~ 130kW | 3.5 ~ 95kW |
TCU Multi-reactors Temperature Control System (Custom Designs)
Temperature Control Range: -120°C to +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperature range | -45°C ~ +250°C series | -120°C ~ +250°C series | Customized Temperature Control System | RT+10°C ~ +135°C |
Heating Capacity | 25 ~ 80kW | 25 ~ 80kW | Custom | 25 ~ 300kW |