Heavy Duty Chiller
How does heavy duty chiller work?
1. Refrigerant cycle
The refrigerant cycle of heavy duty chiller is completed by evaporation and condensation. When the refrigerant evaporates in the evaporator, it absorbs heat, cools the water, and then compresses it into high-temperature and high-pressure gas through the compressor, which enters the condenser for condensation. In the condenser, the heat absorbed by the refrigerant is released, forming a liquid coolant. Next, the liquid coolant enters the evaporator through the plug valve and circulates back and forth for cooling.
2. Evaporative cooling
During the refrigeration process of the heavy duty chiller, the cooling water enters the water inlet in the center direction of the evaporator through the water pump, flows into the bottom of the evaporator, and exposes multiple twisted plug plates, which expands the water flow and vertical distribution, and increases the surface area. Under the action of the plug plate, the cooling water is diffused into a thin water film and flows to the outer surface of the evaporator aluminum plate. The intermolecular force between water molecules is broken, so that part of the cooling water molecules are dissolved in the coolant in the gaseous state, and the other is dissolved in the coolant. Part of the refrigerant absorbs the latent heat of this part of the water molecules and evaporates and cools.
3. Compression
After the refrigerant absorbs heat in the evaporator, it forms a low-temperature and low-pressure gas, which is then sucked into the compressor and compressed into a high-temperature and high-pressure gas with a certain amount of energy. At this time, the temperature of the refrigerant increases, changing from a low-temperature and low-pressure state to a high-temperature and high-pressure state.
4. Condensation
After the high-temperature and high-pressure gas enters the condenser, it goes through a series of processes to change the state of the refrigerant from gaseous to liquid. At the same time, it absorbs a large amount of heat and releases it to the outside of the condenser, thereby achieving the refrigeration effect.
5. Cooling water circulation
During the working process of the heavy duty chiller, in addition to the refrigerant circulation, cooling water also needs to be pumped out of the machine through a water pump and circulated to play a cooling role. After the cooling water flows through the condenser, it takes away the released waste heat and then returns to the evaporator again for circulation cooling.
We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.
We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.
Email: lilia@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
Recirculating Chillers / Refrigerated Circulator
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -25°C ~ +30°C series | -45°C ~ +30°C series | -60°C ~ -20°C series | -80°C ~ -20°C series | -120°C ~ -70°C series | ||||
Cooling Capacity | 0.8 ~ 30kW | 0.75 ~ 12kW | 0.4 ~ 6kW | 0.2 ~ 6kW | 0.3 ~ 5kW | ||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Mini Chillers / Small Chillers
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C series | |||||||
Cooling Capacity | 0.35 ~ 0.9kW | 1.8 ~ 50kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Low Temperature Chillers
We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.
Temperature range | -25°C ~ -5°C series | -45°C ~ -10°C series | -60°C ~ -10°C series | -80°C ~ -30°C series | -110°C ~ -50°C series | -150°C ~ -110°C series | |||
Cooling Capacity | 12 ~ 360kW | 6 ~ 180kW | 6 ~ 180kW | 4 ~ 180kW | 2 ~ 120kW | 2.5 ~ 11kW | |||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
High Temperature Chillers
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | +5°C ~ +40°C | -25°C ~ +40°C | -45°C ~ +40°C | -80°C ~ +80°C | -100°C ~ +80°C | ||||
Cooling Capacity | 6 ~ 40kW | 2 ~ 15kW | 1 ~ 8kW | 0.6 ~ 3kW | 1.5 ~ 3kW | ||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Cooling and Heating Chillers
Temperature Control Range: -120°C to +350°C
cooling and heating thermostat, widely used in various industry.
Temperature range | -10 ~ +150°C series | -25 ~ +200°C series | -25 ~ +300°C series | -45 ~ +250°C series | -45 ~ +300°C series | -60 ~ +250°C series | -60 ~ +300°C series | -70 ~ +250°C series | -80 ~ +250°C series | -90 ~ +250°C series | -100 ~ +100°C series | ||
Cooling Capacity | 1.5 ~ 15kW | 1 ~ 200kW | 1 ~ 200kW | 0.45 ~ 200kW | 0.9 ~ 25kW | 0.25 ~ 60kW | 0.75 ~ 25kW | 0.4 ~ 15kW | 0.3 ~ 80kW | 0.2 ~ 80kW | 0.45 ~ 80kW | ||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Recirculating Heater Chillers
Temperature Control Range: -45°C to +250°C
Temperature range | -25°C ~ +200°C series | -45°C ~ +250°C series | |||||||
Cooling Capacity | 1 ~ 15kW | 0.25 ~ 15kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |