Industrial Glycol Chiller
Contact us today for the perfect temperature control solution
Industrial glycol chiller refers to a mechanical device that uses a compressor to change the pressure change of refrigerant gas to achieve low-temperature refrigeration. Chillers are one of the most important components of compression refrigeration equipment. The working principle of the industrial glycol chiller is to cool the air below 0°C, and the water in the air can condense into water. The cooling source of the air can use the ice water of the chiller, brine or refrigerant, and the condensed water can be removed and reheated to obtain air with low humidity. Chillers are widely used in all walks of life, such as chemical, pharmaceutical, electroplating, plastic, and laser light industries.
The main components of industrial glycol chiller:
Compressor: The chiller uses a semi-hermetic compressor, which is more stable in operation and more reliable in quality.
Condenser and evaporator: The condenser of the industrial glycol chiller is a shell-and-tube water-cooled condenser, and the evaporator can be equipped with a stainless steel shell-and-tube heat exchanger or a brazed plate heat exchanger, all of which are made of high-quality materials , to avoid the occurrence of internal leakage of the product, and to a large extent ensure the operation of the industrial glycol chiller.
Control system: Standard single-chip controller, position setting to turn on refrigeration and turn off the temperature difference of refrigeration, the entire system of industrial glycol chiller is a fully closed system, low temperature does not absorb moisture in the air, and the system will not increase the pressure due to high temperature during operation , Low temperature automatically replenishes the heat transfer medium.
Safety protection: high voltage protection, water cut protection, overcurrent protection, leakage protection, phase continuity and phase failure protection, high temperature protection, sensor failure, low liquid level alarm and other multiple safety protections.
Refrigerant: ethanol water solution, ethylene glycol water solution.
Email: info@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
Precision Chillers / Small Chillers (Custom Designs)
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C series |
Cooling Capacity | 0.35 ~ 0.9kW | 1.8 ~ 50kW |
Recirculating Chillers (Custom Designs)
Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.
Temperature range | -25°C ~ +30°C series | -45°C ~ +30°C series | -60°C ~ -20°C series | -80°C ~ -20°C series | -120°C ~ -70°C series |
Cooling Capacity | 0.8 ~ 30kW | 0.75 ~ 12kW | 0.4 ~ 6kW | 0.2 ~ 6kW | 0.3 ~ 5kW |
Low Temperature Chillers (Custom Designs)
We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.
Temperature range | -25°C ~ -5°C series | -45°C ~ -10°C series | -60°C ~ -10°C series | -80°C ~ -30°C series | -110°C ~ -50°C series | -150°C ~ -110°C series |
Cooling Capacity | 12 ~ 360kW | 6 ~ 180kW | 6 ~ 180kW | 4 ~ 180kW | 2 ~ 120kW | 2.5 ~ 11kW |
Temperature simulation for vehicle quality test: battery life test, fuel injector/motor test bench, airbag test, component test bench, etc.
Suitable for precise temperature control of electronic components. In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing and other environmental testing simulations.
Chillers for Energy Storage(Custom Designs)
Liquid Cooling Solutions For Battery Energy Storage Systems
Temperature range | -45°C ~ +55°C |
Cooling Capacity | 45kW |
Screw Chillers (Custom Designs)
Low temperature screw chillers and room temperature screw chillers
Temperature range | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Cooling Capacity | 107 ~ 1027kW (Single Compressor) | 299 ~ 2134kW (Dual Compressor) | 98 ~ 934kW (Single Compressor) | 272 ~ 1940kW (Dual Compressor) | 48 ~ 467kW (Single Compressor) | 51 ~ 497kW (Single Compressor) |