Recirculating Cooling Water System
Contattateci oggi stesso per la soluzione di controllo della temperatura perfetta
Overview of recirculating cooling water system
A cooling water system that uses water as the cooling medium and circulates it. Mainly composed of cooling equipment, water pumps and pipelines. After the cold water flows through the production equipment that needs to be cooled (often called heat exchange equipment, such as heat exchangers, condensers, reactors), the temperature rises. If it is discharged immediately, the cold water is only used once (called a once-through cooling water system), so that the cold water can be heated up. After flowing through the cooling equipment, the water temperature drops back and can be pumped back to the production equipment for reuse. The consumption of cold water is greatly reduced, often saving more than 95%. Cooling water accounts for about 70% of industrial water consumption. Therefore, the cooling water circulation system plays a role in saving a large amount of industrial water.
Classification of recirculating cooling water systems
Recirculating cooling water systems are divided into open and closed types, so cooling water circulation systems are also divided into open and closed types. Open systems are more complex to design and operate.
Open
There are two types of cooling equipment: cooling pools and cooling towers, both of which mainly rely on the evaporation of water to reduce water temperature. Furthermore, cooling towers often use fans to promote evaporation, and the cooling water is often blown away. Therefore, the open cooling water circulation system must be supplied with fresh water. The circulating water is concentrated due to evaporation, and the concentration process will promote salt scaling (see sediment control). Supplementary water has a dilution effect, and its flow rate is often determined based on the concentration limit of circulating water. Usually the amount of supplementary water exceeds the amount of water lost by evaporation and wind blowing, so some circulating water (called sewage) must be discharged to maintain the balance of water volume. recirculating cooling water system In an open system, due to the contact between water flow and the atmosphere, dust, microorganisms, etc. enter the circulating water; in addition, the escape of carbon dioxide and the leakage of materials in the heat exchange equipment also change the quality of the circulating water. For this reason, circulating cooling water often requires treatment, including sediment control, corrosion control and microbial control. The determination of the treatment method is often related to the quantity and quality of the make-up water, as well as the performance of the production equipment. When using multiple agents, possible chemical reactions between agents should be avoided.
Closed
The closed recirculating cooling water system uses closed cooling equipment. The circulating water flows in the tubes, and wind is usually used outside the tubes to dissipate heat. Except for material leakage from heat exchange equipment, there are no other factors that change the quality of circulating water. To prevent salt scaling in heat exchange equipment, cooling water sometimes needs to be softened. In order to prevent heat exchange equipment from being corroded, corrosion inhibitors are often added; safety must be paid when using high-concentration, highly toxic corrosion inhibitors, and the cooling water discharged during maintenance should be properly disposed of.
Application of recirculating cooling water system
Cooling of heat-generating parts of semiconductor manufacturing equipment:
Single wafer cleaning and reprinting, printing press, automatic chuck installation device, spraying device, ion plating device, etching device, single wafer processing device, slicer, packaging machine, developer temperature management, exposure device, heating of magnetizing parts Devices etc.
Cooling of the heating parts of the laser device:
Laser processing, heating part of welding machine, laser marking device, generating device, carbon dioxide laser processing machine, etc.
Cooling of heating parts of other industrial machines:
Plasma welding, automatic packaging machines, mold cooling, cleaning machinery, gold plating tanks, precision grinders, injection molding machines, molding parts of resin molding machines, etc.
Analyze and detect the cooling of the heating parts of the machine:
The light source of an electron microscope, the light source part of an ICP luminescence spectrometric analysis device, the heating part of a spectrophotometer, the heat source of an X-ray analysis device, the heating part of an automatic pulse banner, the light source of an atomic absorption photometer, etc.
Cooling of cooling medium for CNC machine tools and machining centers.
E-mail: info@lneya.com ID WeChat: +8615251628237 WhatsApp: +86 17851209193
Refrigeratori di precisione / Piccoli refrigeratori
Il refrigeratore può essere ampiamente utilizzato in vari settori industriali e laboratori e supporta la progettazione personalizzata.
Intervallo di temperatura | -18°C ~ +30°C | Serie +5°C ~ +35°C |
Capacità di raffreddamento | 0,35 ~ 0,9 kW | 1,8 ~ 50kW |
Refrigeratori a ricircolo
Il nostro refrigeratore a ricircolo adotta la tecnologia di refrigerazione a bassa temperatura, la temperatura è fino a -120℃ e vari accessori sono personalizzabili.
Intervallo di temperatura | Serie -25°C ~ +30°C | Serie -45°C ~ +30°C | Serie -60°C ~ -20°C | Serie -80°C ~ -20°C | Serie -120°C ~ -70°C |
Capacità di raffreddamento | 0,8 ~ 30kW | 0,75 ~ 12kW | 0,4 ~ 6kW | 0,2 ~ 6kW | 0,3 ~ 5kW |
Refrigeratori a bassa temperatura
Siamo specializzati nella produzione di refrigeratori a bassa temperatura con un range di controllo della temperatura fino a -150°C, in grado di soddisfare le esigenze di refrigerazione di diversi settori industriali.
Intervallo di temperatura | Serie -25°C ~ -5°C | Serie -45°C ~ -10°C | Serie -60°C ~ -10°C | Serie -80°C ~ -30°C | Serie -110°C ~ -50°C | Serie -150°C ~ -110°C |
Capacità di raffreddamento | 12 ~ 360kW | 6 ~ 180kW | 6 ~ 180kW | 4 ~ 180kW | 2 ~ 120kW | 2,5 ~ 11kW |
Simulazione della temperatura per il test di qualità del veicolo: test di durata della batteria, banco di prova dell'iniettore/motore del carburante, test dell'airbag, banco di prova dei componenti, ecc.
Adatto per il controllo preciso della temperatura dei componenti elettronici. Nella produzione di componenti elettronici a semiconduttore per ambienti difficili, le fasi di assemblaggio dell'imballaggio IC e di test di progettazione e produzione includono test termici elettronici e altre simulazioni di test ambientali.
Raffreddamento a liquido per i sistemi di accumulo di energia a batteria
Tipi | Per la stazione di conversione | Per la batteria di accumulo dell'energia | Per la stazione di ricarica |
Capacità di raffreddamento | 45kW | 5 ~ 8,5kW | 4kW |
Serie ZLFQ
Unità di distribuzione del refrigerante
L'apparecchiatura di raffreddamento a liquido è adatta per il test dei semiconduttori, per il test della temperatura costante delle apparecchiature elettroniche, per il raffreddamento dell'infrastruttura di supporto dei server e per altri luoghi di controllo della temperatura dei fluidi.
Intervallo di temperatura | +5°C ~ +35°C | +5°C ~ +35°C |
Capacità di raffreddamento | 15 ~ 150kW | 200 ~ 500kW |
Serie di mandrini termici MD
Viene utilizzato per testare dispositivi RF e dispositivi di potenza ad alta densità (IGBT e MOSFET) e può essere utilizzato anche per il raffreddamento rapido di pannelli piatti da laboratorio (plasma, prodotti biologici, batterie), ecc.
Intervallo di temperatura | -75°C ~ +225°C |
Precisione della temperatura | ±0.1℃ |
Refrigeratori a vite (Disegni personalizzati)
Refrigeratori a vite a bassa temperatura e a temperatura ambiente
Intervallo di temperatura | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Capacità di raffreddamento | 107 ~ 1027kW (compressore singolo) | 299 ~ 2134kW (doppio compressore) | 98 ~ 934kW (compressore singolo) | 272 ~ 1940kW (doppio compressore) | 48 ~ 467kW (compressore singolo) | 51 ~ 497kW (compressore singolo) |