CDU Liquid Cooling Data Center

ClassificazioneNotizie sul settore 244 0

CDU Liquid Cooling Data Center

Contattateci oggi stesso per la soluzione di controllo della temperatura perfetta

 

Server computing power is growing rapidly, and the construction of large-scale data centers with high density and high energy consumption has become a necessary choice to balance computing power and environmental protection regulations. Currently, air conditioners used for server cooling have become a key factor in determining the PUE of data centers because their energy load is higher than that of IT equipment.

The refrigeration system is one of the important infrastructures of the data center. During the operation of high-density data centers, traditional air cooling faces problems of insufficient heat dissipation and serious energy consumption. Liquid cooling technology has become an optimal solution to reduce the PUE of the data center, which is above 15kW/cabinet. more economical advantages.

At present, liquid cooling technology has gradually been adopted in ultra-large data centers with high density and high power supply density around the world. Liquid cooling technology is to directly introduce the liquid cooling system into the server for heat dissipation, or even put the server and other equipment that need heat dissipation directly into the coolant (transmission media such as mineral oil or fluorinated liquid).

The heat is transferred through the liquid-cooled host and then dissipated into the air through the outdoor cooling tower. Since the specific heat capacity of liquid is much larger than that of air, the cooling efficiency is much higher than that of air cooling, and since the fan is omitted, the noise can also be reduced. The server thus achieves high density, low noise, low heat transfer temperature difference, and natural cooling throughout the year.

As the construction pace of ultra-high-density data centers accelerates, traditional air cooling can no longer meet the needs of high cost performance and low PUE. Therefore, liquid cooling technology has become the main path for building data centers in the future. Air cooling refers to a heat dissipation method that transfers the heat emitted by the server motherboard, CPU, etc. to the radiator module through the radiator, and then uses a fan or air conditioner to blow the heat away.

In recent years, heat dissipation solutions have evolved from traditional external computer room air conditioners to AHUs with natural cooling on the direct air side, and then to AHUs with natural cooling on the indirect air side. Technical innovations in air cooling systems continue to emerge, among which Baidu Yangquan is a typical example. Cloud computing center, etc. However, air cooling is still limited to using air as the refrigerant. The heat conduction process of air cooling is complex, the total thermal resistance is large, the heat transfer efficiency is low, and the temperature difference between high and low temperature heat sources is large during the heat exchange process. A lower outdoor low-temperature heat source is needed to guide the heat exchange process. conduct.

The CPU core temperature of liquid-cooled servers can be 20~30°C lower than the extreme temperature of air cooling, and the reliability will be greatly improved. Liquid-cooled servers do not require compressor cooling, which reduces the PUE value of the entire system to less than 1.2 throughout the year. At the same time, the server CPU can be overclocked and computing performance can be improved by 12%.

Cold plate liquid cooling has the highest maturity, and immersion liquid cooling and spray liquid cooling have better energy-saving effects.

Currently, three different liquid cooling solutions each have some application cases in the communications industry.

Among them, cold plate liquid cooling heating devices do not need to come into contact with coolant. They are the earliest in development and have high technological maturity. Cold plate liquid cooling uses micro-channel enhanced heat exchange technology and has extremely high heat dissipation performance. It is used in military radars and high-density data centers. , high-performance computers, power batteries and high-power LED heat dissipation fields. It is an effective application solution to solve the deployment of high-power consumption equipment, improve energy efficiency, reduce refrigeration operating costs, and reduce TCO.

Immersion and spray liquid cooling achieve 100% liquid cooling and have better energy-saving effects; immersion liquid cooling has obvious advantages in heat dissipation and energy saving, and has been widely used in the fields of supercomputing and high-performance computing.

 

modelloZLFQ-15ZLFQ-25ZLFQ-50ZLFQ-75ZLFQ-100ZLFQ-150
Intervallo di temperatura +5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃
Acqua di raffreddamento5℃~30℃ Adottare la valvola di regolazione Siemens/Honeywell per controllare il flusso di acqua di raffreddamento
Precisione del controllo della temperatura±0.2℃±0.5℃±0.5℃±0.5℃±0.5℃±0.5℃
controllo del flusso10~25L/min25~50L/min40~110L/min70~150L/min150~250L/min200~400L/min
Il controllo del flusso è regolato da un convertitore di frequenza, con una precisione di ±0,3L/min.
Capacità di raffreddamento (MAX)15kW25kW50kW75kW100kW150kW
Volume di archiviazione15L30L60L100L150L200L
SalamoiaAcqua, olio di silicone, liquido fluorurato, soluzione acquosa di glicole etilenico, ecc.
Condotto medioSUS304SUS304SUS304SUS304SUS304SUS304
Dimensioni dell'interfaccia di ingresso e di uscitaG3/4G1G1DN32DN40DN50
Interfaccia acqua di raffreddamentoG3/4G1DN40DN50DN50DN65
Flusso d'acqua di raffreddamento 7~20℃2,5 m³/h4m³/h8m³/h13m³/h17m³/h25m³/h
380V 50HZ 1kW1,5kW3kW4kW5kW6kW
conchigliaLamiera laminata a freddo spray RAL7035

 

modelloZLFQ-200ZLFQ-250ZLFQ-300ZLFQ-400ZLFQ-500
Intervallo di temperatura +5℃~35℃
Precisione della temperatura±0.5℃
Controllo del flusso15~30m³/h20~35m³/h25~40m³/h30~60m³/h40~70m³/h
Capacità di raffreddamento (MAX) 200kW250kW300kW400kW500kW
Volume di archiviazione250L300L600L1000L1200L
MedioAcqua, olio di silicone, liquido fluorurato, soluzione acquosa di glicole etilenico, ecc.
Condotto medioSUS304
Dimensioni dell'interfaccia di ingresso e di uscitaDN65DN65DN65DN80DN80
Interfaccia acqua di raffreddamentoDN80DN80DN100DN100DN125
Flusso d'acqua di raffreddamento 7~20℃34m³/h43m³/h51m³/h69m³/h86m³/h
Alimentazione 380V 50HZ7kW7kW8kW9kW13kW
conchigliaLamiera laminata a freddo spray RAL7035

 

CDU Liquid Cooling Data Center

 

Forniamo progettazione e produzione di sistemi di controllo della temperatura completi. Da modelli standard a prodotti completi e personalizzati fino a 1000 tonnellate. Siamo specializzati nell'assistenza ai clienti e ci dedichiamo ad aiutare ogni cliente ad avere il sistema di controllo della temperatura ottimale per le sue esigenze specifiche.

Forniamo soluzioni personalizzate non standard. 

 

E-mail: info@lneya.com    ID WeChat: +8615251628237    WhatsApp: +86 17851209193

 

scansione

Le informazioni sul copyright appartengono a lneya-online.com, si prega di contattare l'e-mail per i dettagli: lilia@lneya.com

Oppure scansionate il codice QR di WhatsApp o WeChat qui sotto per contattarci. 

WhatsAPP WeChat

scansione

Precedente: Il prossimo:
Ultime notizie
Richiesta di preventivo
Nome
Indirizzo e-mail
Telefono
Azienda
Messaggio

购物车

X

我的足迹

X
parole chiave: parole chiaveGioia in bottiglia refrigeratore d'acqua