Four common faults and solutions of 2hp chiller
First, the cooling effect is poor, no cooling
Reasons why the 2hp chiller has poor cooling effect or no cooling:
1. Compressor failure or damage
2. There is refrigerant leakage in the system
3. The display temperature of the computer board is abnormal
4. Overload fault
Solutions for the above situations:
Replace with a new compressor or find the source manufacturer of the chiller for repair;
If the refrigerant leaks, just add enough refrigerant;
If the computer board fails, it must be replaced directly;
Replace the 2hp chiller to achieve the required cooling effect.
Second, high voltage fault alarm
If there is a high-pressure alarm due to a factory operation error, you can solve it yourself by the following methods
1. Check whether the pipeline is unobstructed or blocked.
2. Check the evaporator for blisters and clean it in time.
3.2hp chiller is equipped with condenser, check and clean it regularly.
4. Check whether the control panel is damaged. If the panel is damaged, a high-voltage alarm will appear. At this time, just replace the control panel.
Third, low voltage fault alarm
1. If the pressure is too low, it means that the refrigerant is leaking, and it is enough to find the leak point and make up for it.
2. The pressure controller is damaged, replace it with a new one.
3. The filter is blocked; find out the location of the blockage, unblock it or replace it with a new filter device.
Fourth, water leakage occurs
1. There is water leakage in the water tank; if this happens, go directly to the manufacturer for repair or replace the water tank with a new one.
2. The water pump is leaking; find the manufacturer to replace it.
3. The ball valve is leaking; replace it with a new one.
4. The floating ball leaks water; if the floating ball leaks, it may be that the position of the floating ball is loose or the position is not installed correctly, just re-adjust the position.
Note: If there is water leakage in the water tank, water pump and ball valve, if you find the manufacturer to replace it within the warranty period, it will be free of charge. If the warranty period is over, you will have to pay for it yourself.
低温チラー(水冷式・空冷式)
温度制御範囲:-150℃~-5
当社は、-150℃の温度制御範囲を持つ低温冷凍機の生産を専門としており、さまざまな業界の冷凍ニーズを満たすことができます。
温度範囲 | -25°C ~ -5°Cシリーズ | -45°C ~ -10°Cシリーズ | -60°C ~ -10°Cシリーズ | -80°C ~ -30°Cシリーズ | -110°C ~ -50°Cシリーズ |
冷却能力 | 最大360kW | 最大360kW | 最大360kW | 270kWまで | 180kWまで |
循環式チラー (水冷・空冷)
温度制御範囲:-120℃~+30
私達の再循環のスリラーは低温冷凍の技術を採用し、温度は- 120℃と低く、さまざまな付属品はカスタマイズ可能です。
温度範囲 | -25°C ~ +30°Cシリーズ | -45°C ~ +30°Cシリーズ | -60°C ~ -20°Cシリーズ | -80°C ~ -20°Cシリーズ | -120°C ~ -70°Cシリーズ |
冷却能力 | 最大38kW | 最大12kW | 最大7.2kW | 最大7.2kW | 最大8.6kW |
室温チラー/小型チラー
温度制御範囲+5℃〜+50
チラーは様々な産業や研究所で広く使用することができ、カスタマイズされた設計をサポートしています。
温度範囲 | -18°C ~ +30°C | +5°C ~ +35°Cシリーズ |
冷却能力 | 0.9kWまで | 最大50kW |
直接冷却式冷凍機
温度制御範囲:-120℃~-10
熱交換面積が小さく、熱交換が大きい場所に適している。
温度範囲 | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
コンプレッサーパワー | 8HPまで | 最大8HP*2 | 45HP*3まで |
直接冷却式超低温チラー
温度制御範囲:-150℃~-110
お客様のビジネスにカスタマイズされたソリューションを提供します。
温度範囲 | -150°C〜-110°C |
冷却能力 | 最大11kW |
スクリュー冷凍機
低温スクリュー冷凍機と常温スクリュー冷凍機
お客様のビジネスにカスタマイズされたソリューションを提供します。
温度範囲 | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
冷却能力 | 最大1027kW(シングルコンプレッサー) | 最大2134kW(デュアルコンプレッサー) | 最大934kW(シングルコンプレッサー) | 最大1940kW(デュアルコンプレッサー) | 最大467kW(シングルコンプレッサー) | 最大497kW(シングルコンプレッサー) |