2hp Water Chiller – Cooling Chiller
After any piece of mechanical equipment has been in operation for a long time, there will be a series of problems, and corrosion of industrial chiller equipment is also one of the common ones. In order to avoid corrosion and other phenomena in the 2hp water chiller, we will tell you the reasons for the corrosion of the chiller below, and then you can take effective corresponding measures to avoid problems and even affect the normal production of the factory.
1. Unreasonable selection of installation location
After many companies purchase 2hp water chillers, they have not done anti-corrosion, anti-rust and other processes, so they are directly placed in the indoor environment, and repeatedly exposed to wind and sun, which will cause problems such as shell corrosion after a long time.
2. The water processor is installed incorrectly
Whether the water quality is good or bad determines whether there will be scale and rust in the pipeline. At this time, the water processor plays a very important role. If the water processor is not installed properly, it will cause rust or corrosion.
3. Regularly replace the filter
The filter plays the role of filtering impurities, but after the 2hp water chiller has been running for a long time, it is easy to cause other impurities such as condenser fouling/mud accumulation, so we need to replace the filter regularly to ensure that the inside is clean.
4. There is no blowdown valve installed
The blowdown valve plays a very good blowdown effect on the 2hp water chiller, and it also has corrosion resistance and impact resistance. The main sewage valve has a simple structure and good sealing performance.
5. The water supply pipeline should be equipped with a water meter
The water quality treatment method in the 2hp water chiller generally uses medicaments or bacterial agents. These two methods can kill internal fungi, microorganisms, and various types of dirt, etc., and must be used in accordance with the amount of water replenishment and the amount of water in the system. medicine. If the water supply pipeline is not equipped with a water meter, it will cause inaccurate dispensing, which will lead to corrosion of the pipeline in the later stage and cause greater losses.
6. Air environment and other issues
It is inevitable that there will be special gas flow in factory production, and these special gases will cause harm to the surface of the equipment. If you install a 2hp water chiller in such an environment, you must explain it clearly to the professionals in advance, and you must choose explosion-proof and resistant Corroded pipelines to avoid various problems in the later stage.
For 2hp water chiller, we should maintain regularly, regularly maintain, reduce failure rate, increase service life.
低温チラー(水冷式・空冷式)
温度制御範囲:-150℃~-5
当社は、-150℃の温度制御範囲を持つ低温冷凍機の生産を専門としており、さまざまな業界の冷凍ニーズを満たすことができます。
温度範囲 | -25°C ~ -5°Cシリーズ | -45°C ~ -10°Cシリーズ | -60°C ~ -10°Cシリーズ | -80°C ~ -30°Cシリーズ | -110°C ~ -50°Cシリーズ |
冷却能力 | 最大360kW | 最大360kW | 最大360kW | 270kWまで | 180kWまで |
循環式チラー (水冷・空冷)
温度制御範囲:-120℃~+30
私達の再循環のスリラーは低温冷凍の技術を採用し、温度は- 120℃と低く、さまざまな付属品はカスタマイズ可能です。
温度範囲 | -25°C ~ +30°Cシリーズ | -45°C ~ +30°Cシリーズ | -60°C ~ -20°Cシリーズ | -80°C ~ -20°Cシリーズ | -120°C ~ -70°Cシリーズ |
冷却能力 | 最大38kW | 最大12kW | 最大7.2kW | 最大7.2kW | 最大8.6kW |
室温チラー/小型チラー
温度制御範囲+5℃〜+50
チラーは様々な産業や研究所で広く使用することができ、カスタマイズされた設計をサポートしています。
温度範囲 | -18°C ~ +30°C | +5°C ~ +35°Cシリーズ |
冷却能力 | 0.9kWまで | 最大50kW |
直接冷却式冷凍機
温度制御範囲:-120℃~-10
熱交換面積が小さく、熱交換が大きい場所に適している。
温度範囲 | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
コンプレッサーパワー | 8HPまで | 最大8HP*2 | 45HP*3まで |
直接冷却式超低温チラー
温度制御範囲:-150℃~-110
お客様のビジネスにカスタマイズされたソリューションを提供します。
温度範囲 | -150°C〜-110°C |
冷却能力 | 最大11kW |
スクリュー冷凍機
低温スクリュー冷凍機と常温スクリュー冷凍機
お客様のビジネスにカスタマイズされたソリューションを提供します。
温度範囲 | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
冷却能力 | 最大1027kW(シングルコンプレッサー) | 最大2134kW(デュアルコンプレッサー) | 最大934kW(シングルコンプレッサー) | 最大1940kW(デュアルコンプレッサー) | 最大467kW(シングルコンプレッサー) | 最大497kW(シングルコンプレッサー) |