Cooling System in Data Center
完璧な温度制御ソリューションについては、今すぐお問い合わせください。
With the rapid development of Internet technology, the scale and number of data centers are also expanding. During the operation of the data center computer room, a stable and reliable refrigeration system is essential.
Classification of data center computer room refrigeration systems
Data center computer room refrigeration systems are mainly divided into two categories: air cooling and water cooling.
1. Air-cooled refrigeration system
Air-cooled refrigeration systems are the most common refrigeration method. They mainly use fans to extract hot air from the server room, and exhaust the heat to the outside through air conditioners or cooling towers.
The air-cooled refrigeration system is mainly composed of four parts: fan, condenser, evaporator and control system. The fan is responsible for extracting hot air from the server room; the condenser condenses the moisture in the hot air into liquid and releases a large amount of heat; the evaporator absorbs the moisture in the hot air from the condenser and takes away the heat at the same time; the control system Responsible for adjusting the fan speed to maintain a constant cooling effect.
The air-cooled refrigeration system has the advantages of simple equipment, easy maintenance, and relatively low cost. However, its energy efficiency ratio is relatively low and requires more electricity to maintain the cooling effect.
2. Water cooling refrigeration system
The water-cooled refrigeration system uses the heat of water to take away the heat of the server by directly contacting the server. Water cooling systems can be divided into two types: natural cooling and forced cooling. Natural cooling uses low-temperature water provided by the natural environment for cooling; forced cooling uses a refrigerator to cool the water below the ambient temperature, and then sends the cooled water to the server through a water pump for cooling. The advantage of the water cooling system is that it has higher energy efficiency under the same cooling effect, but the equipment is complex and the maintenance cost is high.
The future development trend of cooling system in data center
As energy prices rise and environmental protection requirements increase, the refrigeration system of data center computer rooms is developing in a more efficient and energy-saving direction. Future data center room cooling systems may be more inclined to use natural cooling or hybrid cooling to reduce dependence on power resources and reduce carbon emissions. At the same time, with the development of AI and big data technology, the cooling system of the data center computer room may also become more intelligent, able to automatically adjust the cooling effect and improve cooling efficiency. In addition, with the development of new materials, future data center room refrigeration systems may use more efficient heat dissipation materials to improve energy efficiency.
The cooling system of the data center computer room is an important factor in ensuring the stable operation of the data center. Whether air-cooled or water-cooled, each has its own unique advantages and disadvantages. In the future, we expect to see the emergence of more efficient, energy-saving, and smarter refrigeration systems to meet the growing cooling needs of data centers.
モデル | ZLFQ-15 | ZLFQ-25 | ZLFQ-50 | ZLFQ-75 | ZLFQ-100 | ZLFQ-150 |
温度範囲 | +5℃~35℃ | +5℃~35℃ | +5℃~35℃ | +5℃~35℃ | +5℃~35℃ | +5℃~35℃ |
冷却水 | 5℃~30℃は冷却水の流れを制御するためにSiemens/Honeywellの調整弁を採用する | |||||
温度制御精度 | ±0.2℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ |
フロー制御 | 10~25L/分 | 25~50L/分 | 40~110L/min | 70~150L/分 | 150~250L/min | 200~400L/分 |
流量制御は周波数変換器によって調整され、精度は±0.3L/minです。 | ||||||
冷却能力(MAX) | 15kW | 25kW | 50kW | 75kW | 100kW | 150kW |
ストレージ・ボリューム | 15L | 30L | 60L | 100L | 150L | 200L |
ブライン | 水、シリコーンオイル、フッ素系液体、エチレングリコール水溶液など | |||||
中規模パイプライン | SUS304 | SUS304 | SUS304 | SUS304 | SUS304 | SUS304 |
入出力インターフェース・サイズ | G3/4 | G1 | G1 | DN32 | DN40 | DN50 |
冷却水インターフェース | G3/4 | G1 | DN40 | DN50 | DN50 | DN65 |
冷却水流量 7~20 | 2.5m³/h | 4m³/h | 8m³/h | 13m³/h | 17m³/h | 25m³/h |
380V 50HZ | 1kW | 1.5kW | 3kW | 4kW | 5kW | 6kW |
シェル | 冷間圧延シートスプレー RAL7035 |
モデル | ZLFQ-200 | ZLFQ-250 | ZLFQ-300 | ZLFQ-400 | ZLFQ-500 |
温度範囲 | +5℃~35℃ | ||||
温度精度 | ±0.5℃ | ||||
フロー制御 | 15~30m³/h | 20~35m³/h | 25~40m³/h | 30~60m³/h | 40~70m³/h |
冷却能力(MAX) | 200kW | 250kW | 300kW | 400kW | 500kW |
ストレージ・ボリューム | 250L | 300L | 600L | 1000L | 1200L |
ミディアム | 水、シリコーンオイル、フッ素系液体、エチレングリコール水溶液など | ||||
中規模パイプライン | SUS304 | ||||
入出力インターフェース・サイズ | DN65 | DN65 | DN65 | DN80 | DN80 |
冷却水インターフェース | DN80 | DN80 | DN100 | DN100 | DN125 |
冷却水流量 7~20 | 34m³/h | 43m³/h | 51m³/h | 69m³/h | 86m³/h |
電源 380V 50HZ | 7kW | 7kW | 8kW | 9kW | 13kW |
シェル | 冷間圧延シートスプレー RAL7035 |
温度制御システムの設計から製造まで。標準モデルから完全なカスタマイズ製品まで 1000トン.私たちはカスタマーサービスに特化し、お客様一人ひとりのニーズに合った最適な温度制御システムを提供することに専念しています。
非標準のカスタマイズされたソリューションを提供します。
Eメール info@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193