With the rapid development of Internet technology, the scale and number of data centers are also expanding. During the operation of the data center computer room, a stable and reliable refrigeration system is essential.

Classification of data center computer room refrigeration systems

Data center computer room refrigeration systems are mainly divided into two categories: air cooling and water cooling.

1. Air-cooled refrigeration system

Air-cooled refrigeration systems are the most common refrigeration method. They mainly use fans to extract hot air from the server room, and exhaust the heat to the outside through air conditioners or cooling towers.

The air-cooled refrigeration system is mainly composed of four parts: fan, condenser, evaporator and control system. The fan is responsible for extracting hot air from the server room; the condenser condenses the moisture in the hot air into liquid and releases a large amount of heat; the evaporator absorbs the moisture in the hot air from the condenser and takes away the heat at the same time; the control system Responsible for adjusting the fan speed to maintain a constant cooling effect.

The air-cooled refrigeration system has the advantages of simple equipment, easy maintenance, and relatively low cost. However, its energy efficiency ratio is relatively low and requires more electricity to maintain the cooling effect.

2. Water cooling refrigeration system

The water-cooled refrigeration system uses the heat of water to take away the heat of the server by directly contacting the server. Water cooling systems can be divided into two types: natural cooling and forced cooling. Natural cooling uses low-temperature water provided by the natural environment for cooling; forced cooling uses a refrigerator to cool the water below the ambient temperature, and then sends the cooled water to the server through a water pump for cooling. The advantage of the water cooling system is that it has higher energy efficiency under the same cooling effect, but the equipment is complex and the maintenance cost is high.

 

Cooling System in Data Center

 

The future development trend of cooling system in data center

As energy prices rise and environmental protection requirements increase, the refrigeration system of data center computer rooms is developing in a more efficient and energy-saving direction. Future data center room cooling systems may be more inclined to use natural cooling or hybrid cooling to reduce dependence on power resources and reduce carbon emissions. At the same time, with the development of AI and big data technology, the cooling system of the data center computer room may also become more intelligent, able to automatically adjust the cooling effect and improve cooling efficiency. In addition, with the development of new materials, future data center room refrigeration systems may use more efficient heat dissipation materials to improve energy efficiency.

The cooling system of the data center computer room is an important factor in ensuring the stable operation of the data center. Whether air-cooled or water-cooled, each has its own unique advantages and disadvantages. In the future, we expect to see the emergence of more efficient, energy-saving, and smarter refrigeration systems to meet the growing cooling needs of data centers.

 

モデルZLFQ-15ZLFQ-25ZLFQ-50ZLFQ-75ZLFQ-100ZLFQ-150
温度範囲 +5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃
冷却水5℃~30℃は冷却水の流れを制御するためにSiemens/Honeywellの調整弁を採用する
温度制御精度±0.2℃±0.5℃±0.5℃±0.5℃±0.5℃±0.5℃
フロー制御10~25L/分25~50L/分40~110L/min70~150L/分150~250L/min200~400L/分
流量制御は周波数変換器によって調整され、精度は±0.3L/minです。
冷却能力(MAX)15kW25kW50kW75kW100kW150kW
ストレージ・ボリューム15L30L60L100L150L200L
ブライン水、シリコーンオイル、フッ素系液体、エチレングリコール水溶液など
中規模パイプラインSUS304SUS304SUS304SUS304SUS304SUS304
入出力インターフェース・サイズG3/4G1G1DN32DN40DN50
冷却水インターフェースG3/4G1DN40DN50DN50DN65
冷却水流量 7~202.5m³/h4m³/h8m³/h13m³/h17m³/h25m³/h
380V 50HZ 1kW1.5kW3kW4kW5kW6kW
シェル冷間圧延シートスプレー RAL7035

 

モデルZLFQ-200ZLFQ-250ZLFQ-300ZLFQ-400ZLFQ-500
温度範囲 +5℃~35℃
温度精度±0.5℃
フロー制御15~30m³/h20~35m³/h25~40m³/h30~60m³/h40~70m³/h
冷却能力(MAX) 200kW250kW300kW400kW500kW
ストレージ・ボリューム250L300L600L1000L1200L
ミディアム水、シリコーンオイル、フッ素系液体、エチレングリコール水溶液など
中規模パイプラインSUS304
入出力インターフェース・サイズDN65DN65DN65DN80DN80
冷却水インターフェースDN80DN80DN100DN100DN125
冷却水流量 7~2034m³/h43m³/h51m³/h69m³/h86m³/h
電源 380V 50HZ7kW7kW8kW9kW13kW
シェル冷間圧延シートスプレー RAL7035

 

冷却分配ユニット

 

温度制御システムの設計から製造まで。標準モデルから完全なカスタマイズ製品まで 1000トン.私たちはカスタマーサービスに特化し、お客様一人ひとりのニーズに合った最適な温度制御システムを提供することに専念しています。

非標準のカスタマイズされたソリューションを提供します。 

 

Eメール info@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 

スキャン

著作権情報はlneya-online.comに帰属します。詳細はメールにてお問い合わせください: lilia@lneya.com

または、下記のWhatsAppまたはWeChatのQRコードをスキャンしてお問い合わせください。 

WhatsAPP WeChat

スキャン

前へ 次ページ
最新ニュース
見積依頼
名称
電子メールアドレス
電話
会社概要
メッセージ

购物车

X

我的足迹

X
キーワードウォーター・チラー喜びの瓶詰め ウォーター・チラーウォーターチラー