Data center liquid cooling solution – a full-link layout of supporting infrastructure for liquid-cooled servers. The liquid-cooled CDU distribution unit provides cooling liquid for the cold plate in the server rack, maximizing the use of the heat exchange of the liquid cooling plate to the main heat source inside the server. Cooling, reducing the use of air cooling systems, helping servers achieve greater power dissipation requirements and greater computing density in a single cabinet, further reducing PUE and assisting the high-quality development of data centers.
1. CDU in Data Center application
With its strong R&D, construction, and operation and maintenance capabilities in the field of data centers, Data has launched a new air-liquid architecture cold plate liquid-cooled CDU with a heat dissipation of up to 15kw. Relying on modular lightweight and intelligent design, the construction of edge computer rooms can be quickly completed and renovation of old computer rooms.
2. Product introduction of CDU in Data Center
CDU distribution unit liquid cooling equipment is suitable for semiconductor testing, electronic equipment constant temperature testing, cooling server supporting infrastructure, and other fluid temperature control places. It is a modular intelligent device with independent heat exchange system, power supply system and monitoring system.
3. Working principle of CDU in Data Center
The cooling water flows into the CDU distribution unit, exchanges heat with the heat transfer medium, takes away the heat of the heat transfer medium, and reaches the intended temperature. It can automatically adjust frequency according to system pressure, temperature and flow rate.
The CDU distribution unit uses liquid cooling heat exchange to cool the main heat source and reduce the use of air cooling systems. The liquid cooling equipment provides cooling fluid circulation for the heating elements, saving air heat exchange links and saving a large amount of energy consumption in the refrigeration system.
The circulation system of the CDU distribution unit adopts a fully sealed design, a magnetic drive pump, a PLC programmable controller, and a 7-inch color touch screen temperature curve display, which can be customized according to user needs.
モデル | ZLFQ-15 | ZLFQ-25 | ZLFQ-50 | ZLFQ-75 | ZLFQ-100 | ZLFQ-150 |
温度範囲 | +5℃~35℃ | +5℃~35℃ | +5℃~35℃ | +5℃~35℃ | +5℃~35℃ | +5℃~35℃ |
冷却水 | 5℃~30℃は冷却水の流れを制御するためにSiemens/Honeywellの調整弁を採用する | |||||
温度制御精度 | ±0.2℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ |
フロー制御 | 10~25L/分 | 25~50L/分 | 40~110L/min | 70~150L/分 | 150~250L/min | 200~400L/分 |
流量制御は周波数変換器によって調整され、精度は±0.3L/minです。 | ||||||
冷却能力(MAX) | 15kW | 25kW | 50kW | 75kW | 100kW | 150kW |
ストレージ・ボリューム | 15L | 30L | 60L | 100L | 150L | 200L |
ブライン | 水、シリコーンオイル、フッ素系液体、エチレングリコール水溶液など | |||||
中規模パイプライン | SUS304 | SUS304 | SUS304 | SUS304 | SUS304 | SUS304 |
入出力インターフェース・サイズ | G3/4 | G1 | G1 | DN32 | DN40 | DN50 |
冷却水インターフェース | G3/4 | G1 | DN40 | DN50 | DN50 | DN65 |
冷却水流量 7~20 | 2.5m³/h | 4m³/h | 8m³/h | 13m³/h | 17m³/h | 25m³/h |
380V 50HZ | 1kW | 1.5kW | 3kW | 4kW | 5kW | 6kW |
シェル | 冷間圧延シートスプレー RAL7035 |
モデル | ZLFQ-200 | ZLFQ-250 | ZLFQ-300 | ZLFQ-400 | ZLFQ-500 |
温度範囲 | +5℃~35℃ | ||||
温度精度 | ±0.5℃ | ||||
フロー制御 | 15~30m³/h | 20~35m³/h | 25~40m³/h | 30~60m³/h | 40~70m³/h |
冷却能力(MAX) | 200kW | 250kW | 300kW | 400kW | 500kW |
ストレージ・ボリューム | 250L | 300L | 600L | 1000L | 1200L |
ミディアム | 水、シリコーンオイル、フッ素系液体、エチレングリコール水溶液など | ||||
中規模パイプライン | SUS304 | ||||
入出力インターフェース・サイズ | DN65 | DN65 | DN65 | DN80 | DN80 |
冷却水インターフェース | DN80 | DN80 | DN100 | DN100 | DN125 |
冷却水流量 7~20 | 34m³/h | 43m³/h | 51m³/h | 69m³/h | 86m³/h |
電源 380V 50HZ | 7kW | 7kW | 8kW | 9kW | 13kW |
シェル | 冷間圧延シートスプレー RAL7035 |
温度制御システムの設計から製造まで。標準モデルから完全なカスタマイズ製品まで 1000トン.私たちはカスタマーサービスに特化し、お客様一人ひとりのニーズに合った最適な温度制御システムを提供することに専念しています。
非標準のカスタマイズされたソリューションを提供します。