Calculation of Cooling Capacity of Industrial Chiller

分類業界ニュース 435

Calculation of Cooling Capacity of Industrial Chiller

 

For industrial production with chillers, when cooling equipment and materials, a technical parameter of cooling capacity needs to be considered, so how is it calculated?

Industrial chillers must have sufficient cooling capacity to reach the required temperature. In theory, many engineers and technicians will choose a larger cooling capacity range. In fact, the larger the chiller, the better. Excessive cooling capacity will lead to large equipment investment and high energy consumption.

Therefore, the key for factories to choose suitable industrial chillers is to calculate the cooling capacity and safety factor scientifically and reasonably.

The cooling capacity of an industrial chiller can be calculated using the following formula:

Refrigeration capacity = chilled water flow × 4.187 × temperature difference × coefficient;

The frozen water flow refers to the frozen water flow required when the machine is running;

The temperature difference refers to the temperature difference between the machine entering and leaving the water;

The specific heat capacity of water is 4.187;

The selection requirement multiplier of air-cooled industrial chillers is 1.3;

For the selection of water-cooled industrial chillers 1.1;

The cooling capacity of the water-cooled chiller is large, but a cooling tower needs to be added to achieve a good cooling effect. The cooling tower is a refrigeration device, which is cooled by water, and the heat of the unit itself is consumed by the cooling water, while the chilled water is cooled by the evaporator, and the water source provided by the cooling tower is mainly the heat exchange in the condenser.

The air-cooled chiller adopts the air cooling method, without cooling tower, cooling water pump, or special machine room, and can be installed on the roof and outdoors. The main refrigeration components of the air-cooled industrial chiller are all international well-known brands, with excellent performance and reliable work.

Under normal circumstances, HP (compressor horsepower) is used to calculate industrial chillers. For example, the cooling capacity requirement of 90KW, 1HP≈2.5kW≈735.5kW, of which 2.5kw is the corresponding cooling capacity, 735kw is the corresponding unit power, and 36HP water cooling is selected. Type industrial chillers can basically meet the requirements.

In the selection of industrial chillers, the most important problem is to calculate the demand for cooling capacity, master the calculation formula of cooling capacity, and refer to the notes in the notes, which basically solves the problem of the selection of chillers.

私たちは、最高級のオンタイムデリバリーをお約束 温度制御機器プロンプトが表示さに裏打ちされ、慎重アフターサービス。 ご相談ください 詳細はこちら!

 


低温冷水機

ウォーターチラー

温度制御範囲:-150℃~+50

 

 


冷暖房システム

ダイナミック温度制御システム

温度制御範囲:-120°C~+350°C

 

 

 


バッテリー冷却システム

自動車用テスト・チラー

温度制御範囲:-40℃~+100

 

 

 


半導体テストチラー

半導体テストチラー

温度制御範囲:-85℃~+250

 

 

 


工業用冷凍庫

工業用冷蔵庫

温度制御範囲:-150℃~-10

著作権情報はlneya-online.comに帰属します。詳細はメールにてお問い合わせください: lilia@lneya.com

または、下記のWhatsAppまたはWeChatのQRコードをスキャンしてお問い合わせください。 

WhatsAPP WeChat

スキャン

前へ 次ページ
最新ニュース
展开更多

购物车

X

我的足迹

X
キーワードウォーター・チラー喜びの瓶詰め ウォーター・チラーウォーターチラー