直接チップ冷却データセンター

分類業界ニュース 220 0

直接チップ冷却データセンター

完璧な温度制御ソリューションについては、今すぐお問い合わせください。

 

With advanced analytics, artificial intelligence, and the digitization of various processes, data center workloads continue to increase, and average rack power consumption has increased significantly. And, as we know, as power consumption increases, so does the amount of waste heat that needs to be removed from the rack and ultimately from the empty space.

In the recent past, when rack power consumption was as high as 20kW, air-based cooling methods could be relied upon to keep IT hardware running safely and efficiently. But as some racks begin to exceed 30kW or more, new cooling methods are needed.

This is partly due to the overall densification of IT hardware, with each new generation of CPUs packing more processing power into smaller and smaller sizes. Workloads such as artificial intelligence (AI) and machine learning (ML) require floating-point operations that are typically delivered through graphics processing units. These GPUs are designed to have normal operating temperatures above 80°C (176°F) when used exclusively for specific workloads.

While there are air-based cooling options for cabinets above 20kW, they are often difficult to install and maintain effectively, essentially passing the point of diminishing returns in cooling capacity. As a result, data center owners and operators are now cautiously pursuing liquid cooling for their new facility projects.

 

直接チップ冷却データセンター

 

Direct to chip cooling data center – single phase

This cooling method requires delivering liquid coolant directly to the server’s hotter components, such as the CPU or GPU, and placing a cold plate directly on the chip. Electrical components never come into direct contact with coolant.

With this approach, fans are still required to provide airflow through the server to remove waste heat. While air cooling infrastructure is significantly reduced, this liquid cooling method is still required to operate correctly.

The coolant can be water or a dielectric fluid, but water poses a risk of outage leaks, however, a leak prevention system (LPS) can be used. Single phase means the coolant does not change state – from liquid to gas.

This is also the same method used in the previous desktop computer example.

Direct to chip cooling data center – two-phase

The two-phase direct chip liquid cooling method is similar to the previous single-phase method, the only difference is that the liquid coolant changes state – from gas to liquid and vice versa as it completes the cooling loop. These systems will always use engineered dielectric fluids.

Two-phase systems are superior to single-phase systems in terms of heat removal and have a lower risk of leakage due to the state-changing properties of the coolant.

 

リクエスト

Eメール info@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 


 

半導体チラー

 

 

ZLFQシリーズカスタムデザイン)

クーラント分配ユニット

液冷装置は、半導体試験、電子機器恒温試験、サーバー支持インフラ冷却、その他の流体温度制御場所に適しています。

 

 

温度範囲 +5°C ~ +35°C +5°C ~ +35°C
冷却能力15~150kW200~500kW
注: -150℃の~ +350℃からの温度較差および冷却容量はカスタマイズすることができる

 

著作権情報はlneya-online.comに帰属します。詳細はメールにてお問い合わせください: lilia@lneya.com

または、下記のWhatsAppまたはWeChatのQRコードをスキャンしてお問い合わせください。 

WhatsAPP WeChat

スキャン

前へ 次ページ
最新ニュース
見積依頼
名称
電子メールアドレス
電話
会社概要
メッセージ

购物车

X

我的足迹

X
キーワードウォーター・チラー喜びの瓶詰め ウォーター・チラーウォーターチラー