化学薬品に最適な冷暖房システム
完璧な温度制御ソリューションについては、今すぐお問い合わせください。
The cooling and heating system for chemical uses the refrigeration system to cool the liquid medium below the set temperature, and then transports the medium to the equipment that needs to be controlled, and raises or lowers the temperature of the equipment to the required temperature range through heat exchange. When the equipment reaches the required temperature, the refrigeration system stops working, and the medium is returned to the refrigeration system for heating or cooling for the next use.
Installation steps of cooling and heating system for chemical
1. Choose a suitable installation location: It should be installed in a well-ventilated, dry, dust-free, and corrosive gas-free environment. At the same time, the equipment should be protected from direct sunlight and rain.
2. Connect the power supply: Connect the power cord to the power socket that meets the requirements of the device. Ensure that the power supply voltage is stable to avoid damage to equipment caused by voltage fluctuations.
3. Connect the cooling water system: Connect the water inlet and outlet to the cooling water system. Make sure the cooling water pressure and flow rate meet equipment requirements.
4. Connect the heat exchanger: Connect the heat exchanger to the medium pipe that needs to be heated or cooled. Make sure the pressure and flow rate of the medium meet the equipment requirements.
Debugging steps for cooling and heating system for chemical
1. Check the equipment: Before starting, check whether the appearance of the equipment is damaged, whether the components are firmly installed, and whether the power cord is connected correctly.
2. Set temperature: Set the target temperature according to test requirements. Note that the target temperature should be within the device’s operating temperature range.
3. Start the device: Turn on the power switch and the device starts running. At this time, the operating status of the equipment should be closely observed, and if there is any abnormality, it should be stopped immediately for inspection.
4. Adjust parameters: During the operation of the equipment, timely adjust the parameters of the equipment, such as temperature, pressure, flow, etc., according to actual test requirements.
5. Check the equipment performance: After the equipment has been running for a period of time, check whether the performance of the equipment meets the test requirements. If there are problems, adjustments should be made in time.
Precautions for cooling and heating system for chemical
1. Installation and debugging should be carried out by professionals to prevent equipment damage or personal injury caused by improper operation.
2. During the operation of the equipment, regular maintenance and inspections should be carried out to ensure the normal operation of the equipment.
3. When the equipment fails, it should be stopped immediately and inspected and repaired by professionals.
Eメール info@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
冷暖房システム (SUNDIシリーズ)
(カスタムデザイン)
温度制御範囲:-120°C~+350°C
用途各種リアクター(マイクロチャンネル、ガラス、ジャケット付きリアクターなど)、蒸留または抽出システム、研究室、大学、研究所、航空宇宙、自動車産業、半導体および電気テスト、化学、製薬、石油化学、生化学、医療、病院、研究開発ワークショップ、航空宇宙、生物学およびその他の産業。
温度範囲 | -10 ~ +150℃シリーズ | -25 ~ +200℃シリーズ | -25 ~ +300℃シリーズ | -45 ~ +250°C シリーズ | -45 ~ +300℃シリーズ | -60 ~ +250°C シリーズ | -60 ~ +300℃シリーズ | -70 ~ +250°C シリーズ | -80 ~ +250°C シリーズ | -90 ~ +250°C シリーズ | -100 ~ +100℃シリーズ | ||
冷却能力 | 1.5 ~ 15kW | 1~200kW | 1~200kW | 0.45~200kW | 0.9 ~ 25kW | 0.25 ~ 60kW | 0.75 ~ 25kW | 0.4 ~ 15kW | 0.3 ~ 80kW | 0.2 ~ 80kW | 0.45 ~ 80kW | ||
注: -150℃の~ +350℃からの温度較差および冷却容量はカスタマイズすることができる |
冷暖房システム(WTDシリーズ)
(カスタムデザイン)
(マイクロチャンネル・チューブリアクター特化型)
温度制御範囲:-70℃~+300
マイクロ流路に特化した設計(液体保持容量が小さく、熱交換容量が大きく、循環システムの圧力損失が高い)
温度範囲 | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C | ||||||
冷却能力 | 1.1 ~ 7.5kW | 1.5 ~ 5.5kW | 11~50kW | ||||||
注: -150℃の~ +350℃からの温度較差および冷却容量はカスタマイズすることができる |
冷暖房サーキュレーター
(カスタムデザイン)
温度制御範囲:-45℃~+250
用途各種リアクター(マイクロチャンネル、ガラス、ジャケット付きリアクターなど)、蒸留または抽出システム、研究室、大学、研究所、航空宇宙、化学、製薬、石油化学、生化学、医療、病院、研究開発ワークショップ、航空宇宙、生物学、その他の産業。
温度範囲 | -25°C ~ +200°Cシリーズ | -45°C ~ +250°C シリーズ | |||||||
冷却能力 | 1 ~ 15kW | 0.25 ~ 15kW | |||||||
注: -150℃の~ +350℃からの温度較差および冷却容量はカスタマイズすることができる |
加熱サーキュレーター
(カスタムデザイン)
温度制御範囲+50℃〜+300
注:UCシリーズは熱媒体の温度を制御することができる。USTシリーズは熱媒の温度を制御できるだけでなく、反応材料の温度も制御できます。
温度範囲 | +50°C ~ +170°C(UCシリーズ) | +50°C ~ +300°C(UCシリーズ) | +50°C ~ +300°C(USTシリーズ) | ||||||
暖房能力 | 5.5 ~ 15kW | 3.5~130kW | 3.5〜95kW | ||||||
注: -150℃の~ +350℃からの温度較差および冷却容量はカスタマイズすることができる |