Cascade Refrigeration System
In the industrial refrigeration cycle system, low temperature can be obtained by adopting two-stage or multi-stage compression refrigeration cycle, which solves the problem of excessive pressure ratio. If the two-stage or multi-stage vapor compression refrigeration cycle cannot meet this requirement, we need to use the cascade refrigeration system. There are three main reasons why cascade refrigeration system must be adopted.
1. The result characteristics of piston compressor valves are limited: low evaporation pressure affects the automatic switching characteristics of reciprocating piston compressor valves, which deviates from the design range. When the suction pressure is 10~16kPa, the suction valve of the compressor does not open, and the compressor cannot suck. On the other hand, the compressor and the low-pressure part of the system operate under high vacuum, and the possibility of intrusion of non-condensable gas becomes high.
2. Limitation of refrigeration cycle pressure ratio: Once the necessary evaporation pressure is too low, even if the two-stage compression refrigeration cycle is used, the pressure ratio of each stage still exceeds the specified value, which greatly reduces the efficiency of the refrigeration cycle. In addition, with multi-stage compression, the cycle pressure is guaranteed, but the refrigeration system is complex and the technical and economic indicators are not high.
3. Restricted by the freezing point of the refrigerant: when the evaporation temperature required by the refrigeration cycle system of the chiller is lower than the freezing point of the refrigerant, the refrigerant freezes and cannot flow, and the system cannot circulate. For example, because the freezing point of R17 is -77.7°C, it is obviously not suitable for the refrigeration cycle system whose evaporation temperature is below -77.7°C.
Based on the above three points, it is unfavorable or impossible to use a single refrigerant multi-stage compression refrigeration cycle chiller to obtain a lower temperature. Although the evaporation temperature of the multi-stage compression refrigeration cycle is lower than that of the single-stage compression refrigeration cycle, it is limited by the physical properties of the refrigerant itself and the working characteristics of the compressor. When the evaporation temperature is lower, the multi-stage compression refrigeration cycle is used. Often can not meet the requirements, at this time, need to use cascade refrigeration system.
低温チラー(水冷式・空冷式)
温度制御範囲:-150℃~-5
当社は、-150℃の温度制御範囲を持つ低温冷凍機の生産を専門としており、さまざまな業界の冷凍ニーズを満たすことができます。
温度範囲 | -25°C ~ -5°Cシリーズ | -45°C ~ -10°Cシリーズ | -60°C ~ -10°Cシリーズ | -80°C ~ -30°Cシリーズ | -110°C ~ -50°Cシリーズ |
冷却能力 | 最大360kW | 最大360kW | 最大360kW | 270kWまで | 180kWまで |
循環式チラー (水冷・空冷)
温度制御範囲:-120℃~+30
私達の再循環のスリラーは低温冷凍の技術を採用し、温度は- 120℃と低く、さまざまな付属品はカスタマイズ可能です。
温度範囲 | -25°C ~ +30°Cシリーズ | -45°C ~ +30°Cシリーズ | -60°C ~ -20°Cシリーズ | -80°C ~ -20°Cシリーズ | -120°C ~ -70°Cシリーズ |
冷却能力 | 最大38kW | 最大12kW | 最大7.2kW | 最大7.2kW | 最大8.6kW |
室温チラー/小型チラー
温度制御範囲+5℃〜+50
チラーは様々な産業や研究所で広く使用することができ、カスタマイズされた設計をサポートしています。
温度範囲 | -18°C ~ +30°C | +5°C ~ +35°Cシリーズ |
冷却能力 | 0.9kWまで | 最大50kW |
直接冷却式冷凍機
温度制御範囲:-120℃~-10
熱交換面積が小さく、熱交換が大きい場所に適している。
温度範囲 | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
コンプレッサーパワー | 8HPまで | 最大8HP*2 | 45HP*3まで |
直接冷却式超低温チラー
温度制御範囲:-150℃~-110
お客様のビジネスにカスタマイズされたソリューションを提供します。
温度範囲 | -150°C〜-110°C |
冷却能力 | 最大11kW |
スクリュー冷凍機
低温スクリュー冷凍機と常温スクリュー冷凍機
お客様のビジネスにカスタマイズされたソリューションを提供します。
温度範囲 | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
冷却能力 | 最大1027kW(シングルコンプレッサー) | 最大2134kW(デュアルコンプレッサー) | 最大934kW(シングルコンプレッサー) | 最大1940kW(デュアルコンプレッサー) | 最大467kW(シングルコンプレッサー) | 最大497kW(シングルコンプレッサー) |