Overview of cold water recirculating system

The cold water recirculating system is configured for water cooling of production equipment. A cooling water system that uses water as the cooling medium and circulates it. After the cold water flows through the production equipment that needs to be cooled (often called heat exchange equipment, such as heat exchangers, condensers, and reactors), the temperature rises. If it is discharged immediately, the cold water is only used once (called a DC cooling water system). When the heated cold water flows through the cooling equipment, the water temperature will drop back, and the consumption of cold water will be greatly reduced, often saving more than 95%. Cooling water accounts for about 70% of industrial water consumption, so cold water recirculating system plays a role in saving a lot of industrial water.

 

冷水循環システム

 

Cold water recirculating system generally consists of the following parts:

1. Heat exchangers in the production process

2. Cooling the structure

3 circulating water pump and sump.

Cooling structures for cooling water cooling treatment generally use cooling pools or cooling towers. Its working process is as follows: the circulating water is transported by the water pump to the water supply main pipe, and then enters each production equipment that needs cooling treatment, flows through the parts that need to be cooled, and then collects into the return water main pipe, and sprays downwards through the water distribution pipe above the cooling water tower . When the fan on the top of the cooling water tower is running, the return water flows back into the water storage tank after sufficient heat exchange with the air flow in the packing layer.

Classification of cold water recirculating system

Cooling equipment can be divided into open type and closed type, so cold water recirculating system is also divided into open type and closed type. Open systems are more complex to design and operate.

Open type: There are two types of cooling equipment, cooling pools and cooling towers, both of which mainly rely on the evaporation of water to reduce the water temperature. Fans are often used in cooling towers to promote evaporation, and cooling water is often blown away. Therefore, the open cold water recirculating system must supply fresh water. Due to evaporation, the circulating water is concentrated, and the concentration process will promote salt scaling. Make-up water has a dilution effect, and its flow rate is often determined according to the concentration limit of circulating water. Usually the amount of added water exceeds the amount of water lost by evaporation and wind, so some circulating water (called sewage) must be discharged to maintain the balance of water.

In an open system, due to the contact between the water flow and the atmosphere, dust, microorganisms, etc. enter the circulating water; in addition, the escape of carbon dioxide and the leakage of materials in the heat exchange equipment also change the water quality of the circulating water. For this reason, circulating cooling water often requires treatment, including sediment control, corrosion control and microbial control. The determination of the treatment method is often related to the water quantity and quality of the make-up water, as well as the performance of the production equipment. When multiple agents are used, possible chemical reactions between agents should be avoided.

Closed The closed cold water recirculating system adopts closed cooling equipment, the circulating water flows in the tube, and the outside of the tube usually uses wind to dissipate heat. Except for the material leakage of the heat exchange equipment, there are no other factors that change the water quality of the circulating water. In order to prevent the formation of salt scale in the heat exchange equipment, sometimes the cooling water needs to be softened. In order to prevent heat exchange equipment from being corroded, corrosion inhibitors are often added; when using high-concentration and highly toxic corrosion inhibitors, pay attention to safety, and the cooling water discharged during maintenance should be properly disposed of.

リクエスト

Eメール info@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 


 

精密冷凍機/小型冷凍機精密冷凍機/小型冷凍機 (カスタムデザイン)

チラーは様々な産業や研究所で広く使用することができ、カスタマイズされた設計をサポートしています。

温度範囲 -18°C ~ +30°C +5°C ~ +35°Cシリーズ
冷却能力0.35 ~ 0.9kW1.8~50kW

 


 

循環式冷凍機

循環式チラー (カスタムデザイン)

私達の再循環のスリラーは低温冷凍の技術を採用し、温度は- 120℃と低く、さまざまな付属品はカスタマイズ可能です。

温度範囲 -25°C ~ +30°Cシリーズ -45°C ~ +30°Cシリーズ -60°C ~ -20°Cシリーズ -80°C ~ -20°Cシリーズ -120°C ~ -70°Cシリーズ
冷却能力0.8 ~ 30kW0.75 ~ 12kW0.4 ~ 6kW0.2 ~ 6kW0.3 ~ 5kW

 


 

低温チラー

低温チラー (カスタムデザイン)

当社は、-150℃の温度制御範囲を持つ低温冷凍機の生産を専門としており、さまざまな業界の冷凍ニーズを満たすことができます。

温度範囲 -25°C ~ -5°Cシリーズ -45°C ~ -10°Cシリーズ -60°C ~ -10°Cシリーズ -80°C ~ -30°Cシリーズ-110°C ~ -50°Cシリーズ -150℃〜-110℃シリーズ
冷却能力12~360kW6~180kW6~180kW4〜180kW2~120kW2.5 ~ 11kW

 


 

Chillers for Automotive Battery Test

(カスタムデザイン)

車両品質テスト用温度シミュレーション:バッテリー寿命テスト、燃料噴射装置/モーターテストベンチ、エアバッグテスト、コンポーネントテストベンチなど。

 

温度範囲 -25°C ~ +100°C -40°C ~ +100°C0°C ~ +100°C  -40°C ~ +135°C
冷却能力2.8~38kW1.2〜60kW1.8〜60kW4〜60kW

 

温度/圧力/流量を個別に制御可能。

1&2: 2つのグループコントロールのための1つの機械。

温度範囲 -40 ~ +100℃ 1&20 ~ +100℃ 1&2
冷却能力1.8kW*2〜60kW*21.8kW*2〜60kW*2

 

温度は一定で、圧力と流量は独立して制御できる。

1&3:3つのグループコントロールのために1つのマシン。

1&6:1台で6グループをコントロール。

温度範囲 -40 ~ +100℃ 1&2 -40 ~ +100℃ 1&3 -40 ~ +100℃ 1&6 -20 ~ +100℃ 1&6 0 ~ +100℃ 1&2 0 ~ +100℃ 1&3 0 ~ +100℃ 1&6
冷却能力2.5〜60kW4〜60kW10 ~ 60kW10 ~ 60kW7~60kW11~60kW18 ~ 60kW

 


 

Chillers for Semiconductor (TES series)

(カスタムデザイン)

電子部品の精密な温度制御に適しています。過酷な環境に対応する半導体電子部品の製造では、ICパッケージの組み立てやエンジニアリング、製造テストの段階で、電子温度テストやその他の環境テストシミュレーションが行われます。

温度範囲 -45°C ~ +250°C シリーズ -85°C ~ +200°Cシリーズ -60°C ~ +200°Cシリーズ
冷却能力0.3 ~ 25kW0.25 ~ 25kW3〜60kW

 


 

Chillers for Semiconductor (LTS series)

(カスタムデザイン)

電子部品の精密な温度制御に適しています。過酷な環境に対応する半導体電子部品の製造では、ICパッケージの組み立てやエンジニアリング、製造テストの段階で、電子温度テストやその他の環境テストシミュレーションが行われます。

温度範囲 -20°C ~ +80°Cシリーズ -45°C ~ +80°Cシリーズ -60°C ~ +80°C シリーズ -80°C ~ +80°Cシリーズ
フロー制御7 ~ 45 L/分7 ~ 45 L/分7 ~ 45 L/分7 ~ 45 L/分

 


 

半導体チラー

Chillers for Semiconductor (FLT series)

 (カスタムデザイン)

半導体の温度調整システムのスリラーは半導体の生産工程およびテスト プロセスの精密な温度調整のために主に使用されます。それは半導体工業のために特に開発され、設計されています。

 

温度範囲 +5°C ~ +40°C -25°C ~ +40°C -45°C ~ +40°C -80°C ~ +80°C -100°C ~ +80°C
冷却能力6〜40kW2~15kW1~8kW0.6 ~ 3kW1.5~3kW

 


 

半導体用チラー

Chillers for Semiconductor (FLTZ Series Frequency Conversion)

(カスタムデザイン)

二重周波数変換シリーズ温度制御システム、循環ポンプとコンプレッサーはすべて周波数変換によって調整されます。

 

温度範囲 -30°C ~ +40°C
冷却能力5~11kW

 


 

半導体チラー

Chillers for Semiconductor (ETCU series)

(カスタムデザイン)

熱交換タイプ

コンプレッサーなしのシステム

 

温度範囲 +5°C ~ +90°C
冷却能力5 ~ 30kW

 


 

冷却水分配ユニット

 

Chillers for Semiconductor (ZLFQ series)

(カスタムデザイン)

クーラント分配ユニット

液冷装置は、半導体試験、電子機器恒温試験、サーバー支持インフラ冷却、その他の流体温度制御場所に適しています。

 

 

温度範囲 +5°C ~ +35°C
冷却能力15~500kW

 


 

 

エネルギー貯蔵用チラー(カスタムデザイン)

Liquid Cooling Solutions For Battery Energy Storage Systems

 

 

 

温度範囲 -45°C ~ +55°C
冷却能力45kW

 

著作権情報はlneya-online.comに帰属します。詳細はメールにてお問い合わせください: lilia@lneya.com

または、下記のWhatsAppまたはWeChatのQRコードをスキャンしてお問い合わせください。 