The glycol water cooling system is a chiller that uses ethylene glycol as the refrigerant.
Sometimes the cooling liquid needs to be below 0℃. If water is used for cooling, it will freeze. Adding some antifreeze liquid can avoid freezing, and ethylene glycol can prevent freezing.
In the all-air system, when the outdoor temperature is too low in winter, it is not easy to implement the air conditioning method of using cooling towers to directly provide cooling to the inner area. At this time, the outdoor cold air can be used as the cold source, ethylene glycol solution can be used as the refrigerant, and the outdoor natural cold source can be introduced indoors to provide cooling to the inner area.
Working principle of glycol water cooling system:
Install a plate heat exchanger outdoors, and a fan will introduce the outdoor cold air into the plate heat exchanger. The ethylene glycol solution and the outdoor cold air will exchange heat in the plate heat exchanger. The cooled ethylene glycol solution enters the air conditioning unit in the inner area, where it exchanges heat with the mixed air (air mixed with new and return air). The mixed air is cooled, and after the temperature drops, it enters the inner room and supplies the indoor air. District room cooling. The temperature of the ethylene glycol solution rises and returns to the outdoor plate heat exchanger again to exchange heat with the cold outdoor air. After the temperature drops, the cycle continues. This type of heat exchange is often used in heat recovery systems. Ethylene glycol exchanges heat with high-temperature exhaust air. After the temperature rises, it enters the fresh air cabinet to preheat the fresh air. Therefore, the heat in the exhaust air is recovered to heat the fresh air, saving electric energy and operating costs.
This method of using ethylene glycol solution as a secondary refrigerant to introduce the cold energy in the outdoor cold air to provide cooling to the inner area is a very energy-saving air conditioning method. Just install a plate heat exchanger outdoors. During operation, the chiller is turned off and only the fan and air conditioning unit are turned on to introduce natural cold sources to provide cooling to the inner area, saving electricity and reducing operating costs. However, in the process of using outdoor cooling to cool the inner area, the cold air needs to exchange heat with ethylene glycol, and then the ethylene glycol needs to exchange heat with the mixed air. After two heat exchanges, the cooling capacity loss is large. , the heat transfer efficiency is not high, generally less than 60%.
Eメール info@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
精密冷凍機/小型冷凍機
(カスタムデザイン)
チラーは様々な産業や研究所で広く使用することができ、カスタマイズされた設計をサポートしています。
温度範囲 | -18°C ~ +30°C | +5°C ~ +35°Cシリーズ |
冷却能力 | 0.35 ~ 0.9kW | 1.8~50kW |
循環式チラー
(カスタムデザイン)
私達の再循環のスリラーは低温冷凍の技術を採用し、温度は- 120℃と低く、さまざまな付属品はカスタマイズ可能です。
温度範囲 | -25°C ~ +30°Cシリーズ | -45°C ~ +30°Cシリーズ | -60°C ~ -20°Cシリーズ | -80°C ~ -20°Cシリーズ | -120°C ~ -70°Cシリーズ |
冷却能力 | 0.8 ~ 30kW | 0.75 ~ 12kW | 0.4 ~ 6kW | 0.2 ~ 6kW | 0.3 ~ 5kW |
低温チラー
(カスタムデザイン)
当社は、-150℃の温度制御範囲を持つ低温冷凍機の生産を専門としており、さまざまな業界の冷凍ニーズを満たすことができます。
温度範囲 | -25°C ~ -5°Cシリーズ | -45°C ~ -10°Cシリーズ | -60°C ~ -10°Cシリーズ | -80°C ~ -30°Cシリーズ | -110°C ~ -50°Cシリーズ | -150℃〜-110℃シリーズ |
冷却能力 | 12~360kW | 6~180kW | 6~180kW | 4〜180kW | 2~120kW | 2.5 ~ 11kW |
(カスタムデザイン)
車両品質テスト用温度シミュレーション:バッテリー寿命テスト、燃料噴射装置/モーターテストベンチ、エアバッグテスト、コンポーネントテストベンチなど。
(カスタムデザイン)
電子部品の精密な温度制御に適しています。過酷な環境に対応する半導体電子部品の製造では、ICパッケージの組み立てやエンジニアリング、製造テストの段階で、電子温度テストやその他の環境テストシミュレーションが行われます。
バッテリーエネルギー貯蔵システム用液体冷却
(カスタムデザイン)
種類 | コンバーティング・ステーション用 | 蓄電池用 | 充電ステーション用 |
冷却能力 | 45kW | 5 ~ 8.5kW | 4kW |
ZLFQシリーズ
(カスタムデザイン)
クーラント分配ユニット
液冷装置は、半導体試験、電子機器恒温試験、サーバー支持インフラ冷却、その他の流体温度制御場所に適しています。
温度範囲 | +5°C ~ +35°C | +5°C ~ +35°C |
冷却能力 | 15~150kW | 200~500kW |
MDサーマルチャックシリーズ
(カスタムデザイン)
RFデバイスや高密度パワーデバイス(IGBTやMOSFET)のテストに使用され、実験用フラットパネル(プラズマ、生物学的製品、バッテリー)などの急速冷却にも使用できる。
温度範囲 | -75°C ~ +225°C |
温度精度 | ±0.1℃ |
スクリュー冷凍機 (カスタムデザイン)
低温スクリュー冷凍機と常温スクリュー冷凍機
温度範囲 | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
冷却能力 | 107~1027kW(シングルコンプレッサー) | 299~2134kW(デュアルコンプレッサー) | 98~934kW(シングルコンプレッサー) | 272~1940kW(デュアルコンプレッサー) | 48~467kW(シングルコンプレッサー) | 51~497kW(シングルコンプレッサー) |