We have 20 models for you to choose from, and we also provide customized services. Please contact our email: info@lneya.com.
LNEYA Model | Temp. range °C | Temp. stability °C | 暖房 容量 キロワット時 | 冷却 容量 キロワット時 | Pump Flow Rate, Pressure l/min bar | パワー |
LY-3020 | 50 ~ 200 | ±0.5 | 3 | | 10 0.7 | 220V 50HZ 2.2kW |
LY-5020 | 50 ~ 200 | ±0.5 | 5.5 | | 35 2 | 380V 50HZ 5.9kW |
LY-A020 | 50 ~ 200 | ±0.5 | 10 | | 50 2 | 380V 50HZ 10.8kW |
UC-3020 | 50 ~ 200 | ±0.5 | 2 | 1.3 @ 100°C | 10 0.7 | 380V 50HZ 3.5kW |
UC-5020 | 50 ~ 200 | ±0.5 | 5.5 | 4 @ 100°C | 35 2 | 380V 50HZ 5.9kW |
UC-A1020 | 50 ~ 200 | ±0.5 | 10 | 8 @ 100°C | 50 2 | 380V 50HZ 10.8kW |
UC-A1520 | 50 ~ 200 | ±0.5 | 15 | 12 @ 100°C | 50 2.5 | 380V 50HZ 15.7kW |
UC-A2520 | 50 ~ 200 | ±0.5 | 25 | 20 @ 100°C | 110 2.5 | 380V 50HZ 26.5kW |
UC-A3820 | 50 ~ 200 | ±0.5 | 38 | 30 @ 100°C | 110 2.5 | 380V 50HZ 39.5kW |
UC-3530 | 50 ~ 300 | ±0.5 | 3.5 | 2.8 @ 100°C | 35 2 | 380V 50HZ 5KW |
UC-5530 | 50 ~ 300 | ±0.5 | 5.5 | 4 @ 100°C | 35 2 | 380V 50HZ 7KW |
UC-7530 | 50 ~ 300 | ±0.5 | 7.5 | 5 @ 100°C | 50 2 | 380V 50HZ 9KW |
UC-A1030 | 50 ~ 300 | ±0.5 | 10 | 7 @ 100°C | 50 2.5 | 380V 50HZ 12kw |
UC-A1530 | 50 ~ 300 | ±0.5 | 15 | 12 @ 100°C | 110 2.5 | 380V 50HZ 17kw |
UC-A2530 | 50 ~ 300 | ±0.5 | 25 | 20 @ 100°C | 150 2.5 | 380V 50HZ 28kw |
UC-A3830 | 50 ~ 300 | ±0.5 | 38 | 30 @ 100°C | 200 2.5 | 380V 50HZ 41kw |
UC-A6030 | 50 ~ 300 | ±0.5 | 60 | 48 @ 100°C | 250 2.5 | 380V 50HZ 65kw |
UC-A9530 | 50 ~ 300 | ±0.5 | 95 | 76 @ 100°C | 400 2.5 | 380V 50HZ 101kw |
UC-A13030 | 50 ~ 300 | ±0.5 | 130 | 100 @ 100°C | 400 2.5 | 380V 50HZ 136kw |
UC-A20030 | 50 ~ 300 | ±0.5 | 200 | 160 @ 100°C | 600 3 | 380V 50HZ 212kw |
特徴
- UC series with function from high temperature to cooling process,from 50°C ~ 300°C.
- 加熱冷却容器を装備し、伝熱面積が大きく、ヒートアップとクールダウンが速く、伝熱オイルの需要が小さい。
- The whole cycle is full closed, there is no oil mist at high temperature, heat transfer oil can not be oxidized and browning. With function of internal PT100 for correcting internal circulation.
- The whole system is closed with expansion tank, the expansion tank and liquid circulation are thermal insulation, do not participate in liquid circulation, regardless of high or low temperature, the medium in expansion tank is limited to 60°C.
アプリケーション
- Various Reactors (Microchannels, Glass or Jacketed Reactors, etc.)
- 研究室
- Research Institute
- Chemical and Pharmaceutical Industry
- petrochemical Industries
- Biochemical Industry
- Medical Industry or Hospital
著作権情報はlneya-online.comに帰属します。詳細はメールにてお問い合わせください: lilia@lneya.com
または、下記のWhatsAppまたはWeChatのQRコードをスキャンしてお問い合わせください。
WhatsAPP WeChat