2hp Water Chiller – Cooling Chiller
After any piece of mechanical equipment has been in operation for a long time, there will be a series of problems, and corrosion of industrial chiller equipment is also one of the common ones. In order to avoid corrosion and other phenomena in the 2hp water chiller, we will tell you the reasons for the corrosion of the chiller below, and then you can take effective corresponding measures to avoid problems and even affect the normal production of the factory.
1. Unreasonable selection of installation location
After many companies purchase 2hp water chillers, they have not done anti-corrosion, anti-rust and other processes, so they are directly placed in the indoor environment, and repeatedly exposed to wind and sun, which will cause problems such as shell corrosion after a long time.
2. The water processor is installed incorrectly
Whether the water quality is good or bad determines whether there will be scale and rust in the pipeline. At this time, the water processor plays a very important role. If the water processor is not installed properly, it will cause rust or corrosion.
3. Regularly replace the filter
The filter plays the role of filtering impurities, but after the 2hp water chiller has been running for a long time, it is easy to cause other impurities such as condenser fouling/mud accumulation, so we need to replace the filter regularly to ensure that the inside is clean.
4. There is no blowdown valve installed
The blowdown valve plays a very good blowdown effect on the 2hp water chiller, and it also has corrosion resistance and impact resistance. The main sewage valve has a simple structure and good sealing performance.
5. The water supply pipeline should be equipped with a water meter
The water quality treatment method in the 2hp water chiller generally uses medicaments or bacterial agents. These two methods can kill internal fungi, microorganisms, and various types of dirt, etc., and must be used in accordance with the amount of water replenishment and the amount of water in the system. medicine. If the water supply pipeline is not equipped with a water meter, it will cause inaccurate dispensing, which will lead to corrosion of the pipeline in the later stage and cause greater losses.
6. Air environment and other issues
It is inevitable that there will be special gas flow in factory production, and these special gases will cause harm to the surface of the equipment. If you install a 2hp water chiller in such an environment, you must explain it clearly to the professionals in advance, and you must choose explosion-proof and resistant Corroded pipelines to avoid various problems in the later stage.
For 2hp water chiller, we should maintain regularly, regularly maintain, reduce failure rate, increase service life.
저온 냉각기(수냉식 및 공냉식)
온도 제어 범위: -150°C ~ -5°C
당사는 -150°C의 낮은 온도 제어 범위를 갖춘 저온 냉각기 생산을 전문으로 하며, 다양한 산업의 냉장 요구 사항을 충족할 수 있습니다.
온도 범위 | -25°C ~ -5°C 시리즈 | -45°C ~ -10°C 시리즈 | -60°C ~ -10°C 시리즈 | -80°C ~ -30°C 시리즈 | -110°C ~ -50°C 시리즈 |
냉각 용량 | 최대 360kW | 최대 360kW | 최대 360kW | 최대 270kW | 최대 180kW |
재순환 냉각기 (수냉식 및 공냉식)
온도 제어 범위: -120°C ~ +30°C
당사의 재순환 냉각기는 저온 냉동 기술을 채택하고 온도가 -120℃까지 낮으며 다양한 액세서리를 사용자 정의 할 수 있습니다.
온도 범위 | -25°C ~ +30°C 시리즈 | -45°C ~ +30°C 시리즈 | -60°C ~ -20°C 시리즈 | -80°C ~ -20°C 시리즈 | -120°C ~ -70°C 시리즈 |
냉각 용량 | 최대 38kW | 최대 12kW | 최대 7.2kW | 최대 7.2kW | 최대 8.6kW |
실온 냉각기/소형 냉각기
온도 제어 범위: +5°C ~ +50°C
이 냉각기는 다양한 산업 및 실험실에서 널리 사용될 수 있으며 맞춤형 설계를 지원합니다.
온도 범위 | -18°C ~ +30°C | +5°C ~ +35°C 시리즈 |
냉각 용량 | 최대 0.9kW | 최대 50kW |
직접 냉각식 냉동 장비
온도 제어 범위: -120°C ~ -10°C
열 교환 면적이 작고 열 교환이 큰 장소에 적합합니다.
온도 범위 | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
압축기 전력 | 최대 8HP | 최대 8HP*2 | 최대 45HP*3 |
직접 냉각식 초저온 냉각기
온도 제어 범위: -150°C ~ -110°C
비즈니스를 위한 맞춤형 솔루션.
온도 범위 | -150°C ~ -110°C |
냉각 용량 | 최대 11kW |
스크류 칠러
저온 스크류 냉각기 및 실온 스크류 냉각기
비즈니스를 위한 맞춤형 솔루션.
온도 범위 | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
냉각 용량 | 최대 1027kW(단일 컴프레서) | 최대 2134kW(듀얼 컴프레서) | 최대 934kW(단일 컴프레서) | 최대 1940kW(듀얼 컴프레서) | 최대 467kW(단일 컴프레서) | 최대 497kW(단일 컴프레서) |