Chiller Refrigeration Cycle
완벽한 온도 제어 솔루션을 위해 지금 바로 문의하세요.
The chiller refrigeration cycle is a device used for industrial cooling. It generally consists of a compressor, condenser, evaporator and water pump. The cooled water is sucked in from the water pump, cooled by the circulating water through the condenser, and then evaporated through the evaporator to reduce the cooling water temperature to the required temperature.
The chiller refrigeration cycle is widely used in the field of industrial refrigeration. Especially in plastic processing, food processing, rubber processing, petrochemicals, cosmetics processing and other industries, the application of chiller refrigeration cycle is becoming more and more widespread. It can not only help companies save energy, but also maintain the health and safety of the production environment while maintaining product production quality.
The chiller refrigeration cycle consists of three interrelated systems: refrigerant circulation system, water circulation system, and electrical automatic control system.
Refrigerant circulation system:
The liquid refrigerant in the evaporator absorbs heat from the water and begins to evaporate. The liquid refrigerant also completely evaporates and becomes gaseous, and is sucked and compressed by the compressor. The gaseous refrigerant absorbs heat through the condenser, condenses into liquid, and passes through the thermal expansion valve ( or capillary tube) after throttling, it becomes low-temperature and low-pressure refrigerant and enters the evaporator to complete the refrigerant cycle process.
Water circulatory system:
물 순환 시스템은 물 탱크에서 사용자가 냉각해야 하는 장비로 물을 펌핑하는 워터 펌프입니다. 냉각된 물은 열을 제거한 다음 온도가 상승한 후 다시 냉각수 탱크로 돌아갑니다.
전기 자동 제어 시스템:
전기 자동 제어 시스템에는 전원 공급 부분과 자동 제어 부분이 포함됩니다.
전원 공급부는 컨택터를 통해 컴프레서, 팬, 워터 펌프 등에 전원을 공급합니다.
The automatic control part includes thermostat, pressure protection, delayer, relay, overload protection, etc., which are combined to achieve automatic start and stop, protection and other functions according to the water temperature.
Maintenance of chiller refrigeration cycle
The compressor of the chiller is a very critical component in the unit. The quality of the compressor is directly related to the stability of the unit, so it requires regular maintenance.
1. Change lubricating oil
After long-term use of the chiller refrigeration cycle, the quality of the lubricating oil will deteriorate, and the impurities and moisture inside the oil will increase, so the oil quality must be regularly observed and checked. Once a problem is discovered, it should be replaced in time. The grade of lubricant replaced must comply with the technical data.
2. Replace filter dryer
The filter dryer is an important component to ensure normal circulation of refrigerant. Since water and refrigerant are immiscible with each other, if there is moisture in the system, it will greatly affect the operating efficiency of the unit. Therefore, it is very important to keep the inside of the system dry. The filter element inside the dry filter must be replaced regularly.
3. Calibration of safety valve
The condenser and evaporator on the chiller are both pressure vessels. According to regulations, a safety valve must be installed on the high-pressure end of the unit, that is, the condenser body. Once the unit is in an abnormal working environment, the safety valve can automatically release the pressure. To prevent possible harm to the human body caused by high pressure. Therefore, regular calibration of the safety valve is very important for the safety of the entire unit.
4. Cleaning of condenser and evaporator
Since the cooling water of the water-cooled condenser is an open circulation loop, tap water is generally used for circulation through the cooling tower. When the calcium salt and magnesium salt content in the water is large, it is easy to decompose and deposit on the cooling water pipes to form scale, which affects heat transfer. Excessive scaling will also reduce the circulation cross-section of the cooling water, reduce the water volume, and increase the condensation pressure. Therefore, when the quality of the cooling water used is poor, the cooling water pipes should be cleaned at least once a year to remove scale and other dirt in the pipes. There are usually two methods for cleaning condenser water pipes:
Use a specialized pipe cleaning gun to clean the pipes.
Use a special cleaning agent to circulate and rinse, or fill it in cooling water, and then replace the solution after 24 hours until it is clean.
완벽한 온도 제어 시스템 설계 및 제조를 제공합니다. 표준 모델부터 완벽한 맞춤형 제품까지 900 . 당사는 고객 서비스를 전문으로 하며 각 고객이 특정 요구에 맞는 최적의 온도 제어 시스템을 갖출 수 있도록 최선을 다하고 있습니다.
비표준 맞춤형 솔루션을 제공합니다. 단일 냉각 냉각기와 냉각 및 난방 콤보 장치를 모두 사용할 수 있습니다.
이메일: info@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
재순환 냉각기/냉장 서큘레이터
(맞춤형 디자인)
이 냉각기는 다양한 산업 및 실험실에서 널리 사용될 수 있으며 맞춤형 설계를 지원합니다.
온도 범위 | -25°C ~ +30°C 시리즈 | -45°C ~ +30°C 시리즈 | -60°C ~ -20°C 시리즈 | -80°C ~ -20°C 시리즈 | -120°C ~ -70°C 시리즈 | ||||
냉각 용량 | 0.8 ~ 30kW | 0.75 ~ 12kW | 0.4 ~ 6kW | 0.2 ~ 6kW | 0.3 ~ 5kW | ||||
참고: -150℃ ~ +350℃의 모든 온도 범위와 모든 냉각 용량을 맞춤 설정할 수 있습니다. |
수냉식 냉각기 / 소형 냉각기
(맞춤형 디자인)
이 냉각기는 다양한 산업 및 실험실에서 널리 사용될 수 있으며 맞춤형 설계를 지원합니다.
온도 범위 | -18°C ~ +30°C | +5°C ~ +35°C 시리즈 | |||||||
냉각 용량 | 0.35 ~ 0.9kW | 1.8 ~ 50kW | |||||||
참고: -150℃ ~ +350℃의 모든 온도 범위와 모든 냉각 용량을 맞춤 설정할 수 있습니다. |
저온 냉각기
(맞춤형 디자인)
당사는 -150°C의 낮은 온도 제어 범위를 갖춘 저온 냉각기 생산을 전문으로 하며, 다양한 산업의 냉장 요구 사항을 충족할 수 있습니다.
온도 범위 | -25°C ~ -5°C 시리즈 | -45°C ~ -10°C 시리즈 | -60°C ~ -10°C 시리즈 | -80°C ~ -30°C 시리즈 | -110°C ~ -50°C 시리즈 | -150°C ~ -110°C 시리즈 | |||
냉각 용량 | 12 ~ 360kW | 6 ~ 180kW | 6 ~ 180kW | 4 ~ 180kW | 2 ~ 120kW | 2.5 ~ 11kW | |||
참고: -150℃ ~ +350℃의 모든 온도 범위와 모든 냉각 용량을 맞춤 설정할 수 있습니다. |
고온 냉각기
(맞춤형 디자인)
이 냉각기는 다양한 산업 및 실험실에서 널리 사용될 수 있으며 맞춤형 설계를 지원합니다.
온도 범위 | +5°C ~ +40°C | -25°C ~ +40°C | -45°C ~ +40°C | -80°C ~ +80°C | -100°C ~ +80°C | ||||
냉각 용량 | 6 ~ 40kW | 2 ~ 15kW | 1~8kW | 0.6 ~ 3kW | 1.5 ~ 3kW | ||||
참고: -150℃ ~ +350℃의 모든 온도 범위와 모든 냉각 용량을 맞춤 설정할 수 있습니다. |
냉각 및 난방 냉각기
(맞춤형 디자인)
온도 제어 범위: -120°C ~ +350°C
다양한 산업 분야에서 널리 사용되는 냉난방 온도 조절기입니다.
온도 범위 | -10 ~ +150°C 시리즈 | -25 ~ +200°C 시리즈 | -25 ~ +300°C 시리즈 | -45 ~ +250°C 시리즈 | -45 ~ +300°C 시리즈 | -60 ~ +250°C 시리즈 | -60 ~ +300°C 시리즈 | -70 ~ +250°C 시리즈 | -80 ~ +250°C 시리즈 | -90 ~ +250°C 시리즈 | -100 ~ +100°C 시리즈 | ||
냉각 용량 | 1.5 ~ 15kW | 1~200kW | 1~200kW | 0.45 ~ 200kW | 0.9 ~ 25kW | 0.25 ~ 60kW | 0.75 ~ 25kW | 0.4 ~ 15kW | 0.3 ~ 80kW | 0.2 ~ 80kW | 0.45 ~ 80kW | ||
참고: -150℃ ~ +350℃의 모든 온도 범위와 모든 냉각 용량을 맞춤 설정할 수 있습니다. |
재순환 히터 냉각기
(맞춤형 디자인)
온도 제어 범위: -45°C ~ +250°C
온도 범위 | -25°C ~ +200°C 시리즈 | -45°C ~ +250°C 시리즈 | |||||||
냉각 용량 | 1 ~ 15kW | 0.25 ~ 15kW | |||||||