Data center liquid cooling solution – a full-link layout of supporting infrastructure for liquid-cooled servers. The liquid-cooled CDU distribution unit provides cooling liquid for the cold plate in the server rack, maximizing the use of the heat exchange of the liquid cooling plate to the main heat source inside the server. Cooling, reducing the use of air cooling systems, helping servers achieve greater power dissipation requirements and greater computing density in a single cabinet, further reducing PUE and assisting the high-quality development of data centers.
1. CDU in Data Center application
With its strong R&D, construction, and operation and maintenance capabilities in the field of data centers, Data has launched a new air-liquid architecture cold plate liquid-cooled CDU with a heat dissipation of up to 15kw. Relying on modular lightweight and intelligent design, the construction of edge computer rooms can be quickly completed and renovation of old computer rooms.
2. Product introduction of CDU in Data Center
CDU distribution unit liquid cooling equipment is suitable for semiconductor testing, electronic equipment constant temperature testing, cooling server supporting infrastructure, and other fluid temperature control places. It is a modular intelligent device with independent heat exchange system, power supply system and monitoring system.
3. Working principle of CDU in Data Center
The cooling water flows into the CDU distribution unit, exchanges heat with the heat transfer medium, takes away the heat of the heat transfer medium, and reaches the intended temperature. It can automatically adjust frequency according to system pressure, temperature and flow rate.
The CDU distribution unit uses liquid cooling heat exchange to cool the main heat source and reduce the use of air cooling systems. The liquid cooling equipment provides cooling fluid circulation for the heating elements, saving air heat exchange links and saving a large amount of energy consumption in the refrigeration system.
The circulation system of the CDU distribution unit adopts a fully sealed design, a magnetic drive pump, a PLC programmable controller, and a 7-inch color touch screen temperature curve display, which can be customized according to user needs.
모델 | ZLFQ-15 | ZLFQ-25 | ZLFQ-50 | ZLFQ-75 | ZLFQ-100 | ZLFQ-150 |
온도 범위 | +5℃~35℃ | +5℃~35℃ | +5℃~35℃ | +5℃~35℃ | +5℃~35℃ | +5℃~35℃ |
냉각수 | 5℃~30℃ 냉각수 흐름을 제어하기 위해 지멘스/허니웰 조절 밸브 채택 | |||||
온도 제어 정확도 | ±0.2℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ |
흐름 제어 | 10~25L/min | 25~50L/min | 40~110L/min | 70~150L/min | 150~250L/min | 200~400L/min |
유량 제어는 주파수 변환기에 의해 조정되며 정확도는 ±0.3L/min입니다. | ||||||
냉각 용량(최대) | 15kW | 25kW | 50kW | 75kW | 100kW | 150kW |
저장 용량 | 15L | 30L | 60L | 100L | 150L | 200L |
소금물 | 물, 실리콘 오일, 불소화 액체, 에틸렌글리콜 수용액 등이 있습니다. | |||||
중간 파이프라인 | SUS304 | SUS304 | SUS304 | SUS304 | SUS304 | SUS304 |
인/아웃 인터페이스 크기 | G3/4 | G1 | G1 | DN32 | DN40 | DN50 |
냉각수 인터페이스 | G3/4 | G1 | DN40 | DN50 | DN50 | DN65 |
냉각수 흐름 7~20℃ | 2.5m³/h | 4m³/h | 8m³/h | 13m³/h | 17m³/h | 25m³/h |
380V 50HZ | 1kW | 1.5kW | 3kW | 4kW | 5kW | 6kW |
shell | 냉간 압연 시트 스프레이 RAL7035 |
모델 | ZLFQ-200 | ZLFQ-250 | ZLFQ-300 | ZLFQ-400 | ZLFQ-500 |
온도 범위 | +5℃~35℃ | ||||
온도 정확도 | ±0.5℃ | ||||
흐름 제어 | 15~30m³/h | 20~35m³/h | 25~40m³/h | 30~60m³/h | 40~70m³/h |
냉각 용량(최대) | 200kW | 250kW | 300kW | 400kW | 500kW |
저장 용량 | 250L | 300L | 600L | 1000L | 1200L |
Medium | 물, 실리콘 오일, 불소화 액체, 에틸렌글리콜 수용액 등이 있습니다. | ||||
중간 파이프라인 | SUS304 | ||||
인/아웃 인터페이스 크기 | DN65 | DN65 | DN65 | DN80 | DN80 |
냉각수 인터페이스 | DN80 | DN80 | DN100 | DN100 | DN125 |
냉각수 흐름 7~20℃ | 34m³/h | 43m³/h | 51m³/h | 69m³/h | 86m³/h |
전원 공급 장치 380V 50HZ | 7kW | 7kW | 8kW | 9kW | 13kW |
shell | 냉간 압연 시트 스프레이 RAL7035 |
완벽한 온도 제어 시스템 설계 및 제조를 제공합니다. 표준 모델부터 완벽한 맞춤형 제품까지 1000톤. 당사는 고객 서비스를 전문으로 하며 각 고객이 특정 요구에 맞는 최적의 온도 제어 시스템을 갖출 수 있도록 최선을 다하고 있습니다.
표준이 아닌 맞춤형 솔루션을 제공합니다.