데이터 센터의 CDU

완벽한 온도 제어 솔루션을 위해 지금 바로 문의하세요.

 

Data center liquid cooling solution – a full-link layout of supporting infrastructure for liquid-cooled servers. The liquid-cooled CDU distribution unit provides cooling liquid for the cold plate in the server rack, maximizing the use of the heat exchange of the liquid cooling plate to the main heat source inside the server. Cooling, reducing the use of air cooling systems, helping servers achieve greater power dissipation requirements and greater computing density in a single cabinet, further reducing PUE and assisting the high-quality development of data centers.

1. CDU in Data Center application

With its strong R&D, construction, and operation and maintenance capabilities in the field of data centers, Data has launched a new air-liquid architecture cold plate liquid-cooled CDU with a heat dissipation of up to 15kw. Relying on modular lightweight and intelligent design, the construction of edge computer rooms can be quickly completed and renovation of old computer rooms.

2. Product introduction of CDU in Data Center

CDU distribution unit liquid cooling equipment is suitable for semiconductor testing, electronic equipment constant temperature testing, cooling server supporting infrastructure, and other fluid temperature control places. It is a modular intelligent device with independent heat exchange system, power supply system and monitoring system.

3. Working principle of CDU in Data Center

The cooling water flows into the CDU distribution unit, exchanges heat with the heat transfer medium, takes away the heat of the heat transfer medium, and reaches the intended temperature. It can automatically adjust frequency according to system pressure, temperature and flow rate.

The CDU distribution unit uses liquid cooling heat exchange to cool the main heat source and reduce the use of air cooling systems. The liquid cooling equipment provides cooling fluid circulation for the heating elements, saving air heat exchange links and saving a large amount of energy consumption in the refrigeration system.

The circulation system of the CDU distribution unit adopts a fully sealed design, a magnetic drive pump, a PLC programmable controller, and a 7-inch color touch screen temperature curve display, which can be customized according to user needs.

 

모델ZLFQ-15ZLFQ-25ZLFQ-50ZLFQ-75ZLFQ-100ZLFQ-150
온도 범위 +5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃
냉각수5℃~30℃ 냉각수 흐름을 제어하기 위해 지멘스/허니웰 조절 밸브 채택
온도 제어 정확도±0.2℃±0.5℃±0.5℃±0.5℃±0.5℃±0.5℃
흐름 제어10~25L/min25~50L/min40~110L/min70~150L/min150~250L/min200~400L/min
유량 제어는 주파수 변환기에 의해 조정되며 정확도는 ±0.3L/min입니다.
냉각 용량(최대)15kW25kW50kW75kW100kW150kW
저장 용량15L30L60L100L150L200L
소금물물, 실리콘 오일, 불소화 액체, 에틸렌글리콜 수용액 등이 있습니다.
중간 파이프라인SUS304SUS304SUS304SUS304SUS304SUS304
인/아웃 인터페이스 크기G3/4G1G1DN32DN40DN50
냉각수 인터페이스G3/4G1DN40DN50DN50DN65
냉각수 흐름 7~20℃2.5m³/h4m³/h8m³/h13m³/h17m³/h25m³/h
380V 50HZ 1kW1.5kW3kW4kW5kW6kW
shell냉간 압연 시트 스프레이 RAL7035

 

모델ZLFQ-200ZLFQ-250ZLFQ-300ZLFQ-400ZLFQ-500
온도 범위 +5℃~35℃
온도 정확도±0.5℃
흐름 제어15~30m³/h20~35m³/h25~40m³/h30~60m³/h40~70m³/h
냉각 용량(최대) 200kW250kW300kW400kW500kW
저장 용량250L300L600L1000L1200L
Medium물, 실리콘 오일, 불소화 액체, 에틸렌글리콜 수용액 등이 있습니다.
중간 파이프라인SUS304
인/아웃 인터페이스 크기DN65DN65DN65DN80DN80
냉각수 인터페이스DN80DN80DN100DN100DN125
냉각수 흐름 7~20℃34m³/h43m³/h51m³/h69m³/h86m³/h
전원 공급 장치 380V 50HZ7kW7kW8kW9kW13kW
shell냉간 압연 시트 스프레이 RAL7035

 

데이터 센터의 CDU

 

완벽한 온도 제어 시스템 설계 및 제조를 제공합니다. 표준 모델부터 완벽한 맞춤형 제품까지 1000톤. 당사는 고객 서비스를 전문으로 하며 각 고객이 특정 요구에 맞는 최적의 온도 제어 시스템을 갖출 수 있도록 최선을 다하고 있습니다.

표준이 아닌 맞춤형 솔루션을 제공합니다. 

 

이메일: info@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 

스캔

저작권 정보는 lneya-online.com에 귀속되며 자세한 내용은 이메일로 문의하시기 바랍니다: lilia@lneya.com

또는 아래의 WhatsApp 또는 WeChat QR 코드를 스캔하여 문의하세요. 

왓츠앱 위챗

스캔

이전: 다음:
최신 뉴스
견적 요청하기
이름
이메일 주소
전화
회사
메시지

购物车

X

我的足迹

X
키워드: 키워드병에 담긴 기쁨 물 냉각기