How chilled water cooling systems work?

The chiller compresses the refrigerant into a liquid state through the compressor and sends it to the evaporator for heat exchange with the chilled water to cool the chilled water. The chilled water pump sends the chilled water to the cooling coil at each fan outlet, and the fan blows cold air to achieve cooling. the goal of. The evaporated refrigerant releases heat in the condenser and exchanges heat with the cooling circulating water. The cooling water pump sends the cooling water with heat to the water tower, where the water tower fan sprays and cools it, and communicates with the atmosphere. Heat exchange occurs between them and the heat is dissipated into the atmosphere.

It consists of cooling pump, cooling water pipeline and cooling tower. While the refrigeration host is performing heat exchange and cooling the water temperature, it will certainly release a large amount of heat. This heat is absorbed by the cooling water, causing the cooling water temperature to rise. The cooling pump presses the heated cooling water into the cooling tower, allowing it to exchange heat with the atmosphere in the cooling tower, and then returns the cooled cooling water back to the refrigeration unit. Such a continuous cycle takes away the heat released by the freezing host. The cooling water flowing into the refrigeration host is referred to as “inlet water”, and the cooling water flowing back from the refrigeration host to the cooling tower is referred to as “return water”. Likewise, the temperature of the return water will be higher than the temperature of the incoming water, creating a temperature difference.

 

Chilled Water Cooling Systems

 

Chilled water cooling systems are further divided into closed circulating cooling water systems and open circulating cooling water systems.

When cooling water circulates in a completely closed system consisting of heat exchangers and pipelines, it is called a closed circulation system. In a closed circulation system, the heat absorbed by the cooling water is generally cooled by air. During the water circulation process, there is no other water loss except leakage, and there are no environmental problems caused by sewage discharge. The salt content in the system and The chemicals added remain almost unchanged, so the water quality treatment is relatively simple. However, closed circulating cooling water has serious corrosive corrosion product problems. Closed circulation systems are generally only used in areas with small water volumes or water shortages.

Cold water flows into the heat exchanger to cool the hot fluid. After the water temperature rises, it uses the remaining pressure to flow into the cooling tower for cooling. The cooled water is then pumped into the heat exchanger for recycling. This system is called open circulating cooling water. system. This kind of open circulating cooling water needs to evaporate part of the water and discharge a certain amount of concentrated water during the circulation process. Therefore, a certain amount of fresh water (usually called water replenishment) must be added to maintain the salt content or The content of a certain ion is at a certain value.

The open circulating cooling water system is the most widely used system and also the system with the most complex water quality treatment technology.

요청

이메일: info@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 


 

정밀 냉각기 / 소형 냉각기정밀 냉각기 / 소형 냉각기

(맞춤형 디자인)

이 냉각기는 다양한 산업 및 실험실에서 널리 사용될 수 있으며 맞춤형 설계를 지원합니다.

온도 범위 -18°C ~ +30°C +5°C ~ +35°C 시리즈
냉각 용량0.35 ~ 0.9kW1.8 ~ 50kW

 


 

재순환 냉각기

재순환 냉각기

(맞춤형 디자인)

당사의 재순환 냉각기는 저온 냉동 기술을 채택하고 온도가 -120℃까지 낮으며 다양한 액세서리를 사용자 정의 할 수 있습니다.

온도 범위 -25°C ~ +30°C 시리즈 -45°C ~ +30°C 시리즈 -60°C ~ -20°C 시리즈 -80°C ~ -20°C 시리즈 -120°C ~ -70°C 시리즈
냉각 용량0.8 ~ 30kW0.75 ~ 12kW0.4 ~ 6kW0.2 ~ 6kW0.3 ~ 5kW

 


 

저온 냉각기

저온 냉각기

(맞춤형 디자인)

당사는 -150°C의 낮은 온도 제어 범위를 갖춘 저온 냉각기 생산을 전문으로 하며, 다양한 산업의 냉장 요구 사항을 충족할 수 있습니다.

온도 범위 -25°C ~ -5°C 시리즈 -45°C ~ -10°C 시리즈 -60°C ~ -10°C 시리즈 -80°C ~ -30°C 시리즈-110°C ~ -50°C 시리즈 -150°C ~ -110°C 시리즈
냉각 용량12 ~ 360kW6 ~ 180kW6 ~ 180kW4 ~ 180kW2 ~ 120kW2.5 ~ 11kW

 


 

자동차 테스트용 냉각기

(맞춤형 디자인)

차량 품질 테스트를 위한 온도 시뮬레이션: 배터리 수명 테스트, 연료 인젝터/모터 테스트 벤치, 에어백 테스트, 부품 테스트 벤치 등

 

 


 

반도체용 냉각기

(맞춤형 디자인)

전자 부품의 정밀한 온도 제어에 적합합니다. 열악한 환경을 위한 반도체 전자 부품 제조에서 IC 패키징 조립 및 엔지니어링 및 생산 테스트 단계에는 전자 열 테스트 및 기타 환경 테스트 시뮬레이션이 포함됩니다.

 


 

에너지 저장용 냉각기

 

배터리 에너지 저장 시스템용 액체 냉각

(맞춤형 디자인)

 

 

 

 

유형변환 스테이션의 경우에너지 저장 배터리용충전소용
냉각 용량45kW5~8.5kW4kW

 


 

냉각수 분배 장치

 

ZLFQ 시리즈

(맞춤형 디자인)

냉각수 분배 장치

액체 냉각 장비는 반도체 테스트, 전자 장비 항온 테스트, 서버 지원 인프라 냉각 및 기타 유체 온도 제어 장소에 적합합니다.

 

 

온도 범위 +5°C ~ +35°C +5°C ~ +35°C
냉각 용량15 ~ 150kW200 ~ 500kW

 


 

열 척

 

MD 써멀 척 시리즈

(맞춤형 디자인)

RF 디바이스 및 고밀도 전력 디바이스(IGBT 및 MOSFET) 테스트에 사용되며 실험실 평판(플라즈마, 생물학적 제품, 배터리) 등의 급속 냉각에도 사용할 수 있습니다.

 

 

온도 범위 -75°C ~ +225°C
온도 정확도±0.1℃

 


스크류 냉각기

 

스크류 칠러 (맞춤형 디자인)

저온 스크류 냉각기 및 실온 스크류 냉각기

 

 

온도 범위 +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
냉각 용량107 ~ 1027kW(단일 컴프레서)299 ~ 2134kW(듀얼 컴프레서)98~934kW(단일 컴프레서)272 ~ 1940kW(듀얼 컴프레서)48 ~ 467kW(단일 컴프레서)51 ~ 497kW(단일 컴프레서)