Circulating Cooling System

분류업계 뉴스 250 0

Circulating Cooling System

완벽한 온도 제어 솔루션을 위해 지금 바로 문의하세요.

 

The four major components of the circulating cooling system: compressor, condenser, throttling mechanism, and evaporator.

The functions of the four major components of the circulating cooling system

압축기-adiabatic compression function: compresses medium-low temperature and low-pressure refrigerant into high-temperature and high-pressure superheated steam.

콘덴서 – Condensation (heat release): The high-temperature and high-pressure gaseous refrigerant dissipates heat through heat exchange, and the refrigerant becomes a medium-high-temperature and high-pressure liquid.

The throttling mechanism has a throttling effect: through the throttling effect, the medium-high temperature and high-pressure liquid refrigerant is turned into a low-temperature and low-pressure gas-liquid two-phase refrigerant.

증발기-evaporation effect (heat absorption): The refrigerant absorbs heat when flowing through the evaporator, and turns the refrigerant into a medium-low-temperature and low-pressure gaseous refrigerant through the action of the heat exchanger.

 

Circulating Cooling System

 

The role of other components of the circulating cooling system

High and low pressure controller: The high and low pressure protector of the refrigeration system. When the high pressure is too high or the low pressure is too low, an alarm signal is generated.

Oil separator: Separates the refrigerant and refrigeration oil in the exhaust pipe. The refrigerant continues to enter the condenser along the pipeline, and the separated refrigeration oil returns to the compressor through the oil return pipe.

Condensing pressure regulating valve: It plays the role of regulating the condensing pressure. It can prevent the condensing pressure from being too high and causing high-pressure protection. It can also prevent the condensing pressure from being too low and causing insufficient pressure difference between the front and rear of the throttling structure. Of course, not every system needs this valve.

Reservoir: Stores excess refrigerant in the refrigeration system.

Under low-temperature conditions, the refrigerant circulating in the refrigeration system will be much lower than the refrigerant under normal temperature conditions. If there is no liquid reservoir at this time, the excess refrigerant will be stored in the condenser, accounting for most of the replacement time. thermal area.

Ball valve: A manually opened and closed valve that can cut off the refrigerant circuit.

01) It can be used to close the refrigerant in the condenser or liquid receiver when replacing the filter or thermal expansion valve, so that there is no need to drain the refrigerant of the entire system.

02) Add refrigerant to the system: When debugging a new machine, all the refrigerant cannot be added in the shutdown state. At this time, you need to turn on the compressor and suck the refrigerant into the system through the suction pipe of the compressor. However, many normal temperature During working conditions, the pressure of the evaporator is actually not low or even higher than the pressure of the refrigerant tank, and the refrigerant cannot be added either. Then at this time we can close the ball valve and switch the refrigerant coming from the condensing side, and the compressor can suck the refrigerant into the system.

03) Recycle refrigerant

Drying filter: As the name suggests, it plays the role of removing moisture and filtering impurities in the refrigeration system. This filter is placed in front of the expansion valve to prevent impurities from entering the valve core and blocking the expansion valve.

Solenoid valve: An electric component that can cut off the refrigeration pipeline manually or automatically; it also plays a great role in the refrigeration system.

Evaporation pressure regulating valve: mainly prevents the evaporation pressure from being too high, causing compressor failure.

Crankcase pressure regulating valve: It can also be called suction pressure regulating valve to prevent excessive suction pressure from causing excessive load on the compressor and damaging the compressor.

The evaporation pressure regulating valve and crankcase pressure regulating valve are not required by everyone’s system. Generally, in small systems, we can use a thermal expansion valve with MOP function instead.

Suction filter: Installed on the suction pipe to filter impurities in the refrigeration system to prevent them from entering the compressor and causing compressor failure.

 


 

완벽한 온도 제어 시스템 설계 및 제조를 제공합니다. 표준 모델부터 완벽한 맞춤형 제품까지 900 . 당사는 고객 서비스를 전문으로 하며 각 고객이 특정 요구에 맞는 최적의 온도 제어 시스템을 갖출 수 있도록 최선을 다하고 있습니다.

비표준 맞춤형 솔루션을 제공합니다. 단일 냉각 냉각기와 냉각 및 난방 콤보 장치를 모두 사용할 수 있습니다.

요청

이메일: info@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 


 

냉각 냉각기                                                                                                     

 

재순환 냉각기

재순환 냉각기/냉장 서큘레이터

(맞춤형 디자인)

이 냉각기는 다양한 산업 및 실험실에서 널리 사용될 수 있으며 맞춤형 설계를 지원합니다.

 

 

온도 범위 -25°C ~ +30°C 시리즈 -45°C ~ +30°C 시리즈 -60°C ~ -20°C 시리즈 -80°C ~ -20°C 시리즈 -120°C ~ -70°C 시리즈
냉각 용량0.8 ~ 30kW0.75 ~ 12kW0.4 ~ 6kW0.2 ~ 6kW0.3 ~ 5kW
참고: -150℃ ~ +350℃의 모든 온도 범위와 모든 냉각 용량을 맞춤 설정할 수 있습니다.

 


 

정밀 냉각기 / 소형 냉각기수냉식 냉각기 / 소형 냉각기

(맞춤형 디자인)

이 냉각기는 다양한 산업 및 실험실에서 널리 사용될 수 있으며 맞춤형 설계를 지원합니다.

 

 

온도 범위 -18°C ~ +30°C +5°C ~ +35°C 시리즈
냉각 용량0.35 ~ 0.9kW1.8 ~ 50kW
참고: -150℃ ~ +350℃의 모든 온도 범위와 모든 냉각 용량을 맞춤 설정할 수 있습니다.

 


 

저온 냉각기

저온 냉각기

(맞춤형 디자인)

당사는 -150°C의 낮은 온도 제어 범위를 갖춘 저온 냉각기 생산을 전문으로 하며, 다양한 산업의 냉장 요구 사항을 충족할 수 있습니다.

 

 

온도 범위 -25°C ~ -5°C 시리즈 -45°C ~ -10°C 시리즈 -60°C ~ -10°C 시리즈 -80°C ~ -30°C 시리즈-110°C ~ -50°C 시리즈 -150°C ~ -110°C 시리즈
냉각 용량12 ~ 360kW6 ~ 180kW6 ~ 180kW4 ~ 180kW2 ~ 120kW2.5 ~ 11kW
참고: -150℃ ~ +350℃의 모든 온도 범위와 모든 냉각 용량을 맞춤 설정할 수 있습니다.

 


반도체 냉각기

 

고온 냉각기

(맞춤형 디자인)

이 냉각기는 다양한 산업 및 실험실에서 널리 사용될 수 있으며 맞춤형 설계를 지원합니다.

 

 

온도 범위 +5°C ~ +40°C -25°C ~ +40°C -45°C ~ +40°C -80°C ~ +80°C -100°C ~ +80°C
냉각 용량6 ~ 40kW2 ~ 15kW1~8kW0.6 ~ 3kW1.5 ~ 3kW
참고: -150℃ ~ +350℃의 모든 온도 범위와 모든 냉각 용량을 맞춤 설정할 수 있습니다.

 

 

냉각 및 난방 냉각기                                                                            

 

냉각 및 난방 냉각기

(맞춤형 디자인)

온도 제어 범위: -120°C ~ +350°C

다양한 산업 분야에서 널리 사용되는 냉난방 온도 조절기입니다.

 

온도 범위 -10 ~ +150°C 시리즈 -25 ~ +200°C 시리즈 -25 ~ +300°C 시리즈 -45 ~ +250°C 시리즈 -45 ~ +300°C 시리즈 -60 ~ +250°C 시리즈 -60 ~ +300°C 시리즈 -70 ~ +250°C 시리즈 -80 ~ +250°C 시리즈-90 ~ +250°C 시리즈 -100 ~ +100°C 시리즈
냉각 용량1.5 ~ 15kW1~200kW1~200kW0.45 ~ 200kW0.9 ~ 25kW0.25 ~ 60kW0.75 ~ 25kW0.4 ~ 15kW0.3 ~ 80kW0.2 ~ 80kW0.45 ~ 80kW
참고: -150℃ ~ +350℃의 모든 온도 범위와 모든 냉각 용량을 맞춤 설정할 수 있습니다.

 


 

재순환 히터 냉각기

(맞춤형 디자인)

온도 제어 범위: -45°C ~ +250°C

 

온도 범위 -25°C ~ +200°C 시리즈 -45°C ~ +250°C 시리즈
냉각 용량1 ~ 15kW0.25 ~ 15kW
참고: -150℃ ~ +350℃의 모든 온도 범위와 모든 냉각 용량을 맞춤 설정할 수 있습니다.

저작권 정보는 lneya-online.com에 귀속되며 자세한 내용은 이메일로 문의하시기 바랍니다: lilia@lneya.com