검색 모두 검색

Heater and Cooler

분류업계 뉴스 314

Heater and Cooler

 

Heater and cooler is also called cooling and heating integrated machine, which mainly provides high and low temperature circulating fluid for equipment that needs heating or cooling, such as glass reactors and rotary evaporators. Heated by heat conduction oil, circulated to the jacket layer of the reaction kettle through the circulation pump, and a periodic cycle is carried out in the pipeline and the jacket. With unique heating design, the temperature can be automatically controlled to quickly reach the temperature required by the product process, and intelligent PID is adopted. Control technology, can heat constant temperature or cool down, wide temperature control range, accurate, uniform and stable temperature, fast heat conduction speed, fast temperature rise and fall speed, temperature self-control, quickly meet the temperature requirements of various products.

The compressor is one of the main components of the heater and cooler. If it is not maintained for a long time, its performance will affect the cooling effect. If it fails, its refrigeration system cannot be operated. The compressor in this unit is high temperature and low pressure refrigerant is compressed into high temperature and high pressure, so that the refrigeration system of the unit can achieve the required temperature range. As a main accessory, the compressor’s performance is related to the operation of the entire device, so the compressor needs to be maintained after long-term use.

The compressor will protect itself when it is overloaded or overheated, and this protection device has two types: built-in type and external type, and only the external type is mentioned here. If the compressor cannot start automatically within 3 minutes after the protection occurs, it means that the protector has been activated. After the protection occurs, due to the high temperature of the compressor body and slow heat dissipation, the reset time of the protector is relatively long, usually 3 to 15 minutes, and the longest can reach 30 minutes. If it still fails to start after 30 minutes, the overload and overheat protector may be damaged.

When the capacitor capacity of the compressor decays to 58% of its original value, when the outdoor ambient temperature is lower than minus 5°C, when the power supply voltage is lower than 16%, and when the system pressure is not yet balanced. These factors will cause difficulty in starting the compressor. In fact, the shaft holding and the stuck cylinder have the same meaning. It is a compressor failure or the compressor has been damaged. The main reason for the stuck cylinder is that the system is dirty or lacks oil. Generally, the cylinder body and the valve plate will be damaged to varying degrees. In principle, it cannot be repaired or cannot be repaired, and the compressor needs to be replaced with a new one. However, there are many experiences in dealing with cylinder jams, and some compressors with less serious cylinder jams can be saved by knocking, increasing capacitors, etc.

 

비즈니스를 위한 맞춤형 솔루션


냉난방 시스템(SUNDI 시리즈)

온도 제어 범위: -120°C ~ +350°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

온도 범위 -40 ~ +200°C 시리즈 -10 ~ +200°C 시리즈 -25 ~ +200°C 시리즈 -25 ~ +300°C 시리즈 -45 ~ +250°C 시리즈 -45 ~ +300°C 시리즈 -60 ~ +250°C 시리즈 -60 ~ +300°C 시리즈 -70 ~ +250°C 시리즈 -80 ~ +250°C 시리즈-90 ~ +250°C 시리즈 -100 ~ +100°C 시리즈 -25 ~ +200°C, 원자로 두 대용 장비 한 대 -40 ~ +200°C, 원자로 두 대용 장비 한 대
냉각 용량최대 3kW최대 15kW최대 200kW최대 200kW최대 200kW최대 25kW최대 60kW최대 25kW최대 15kW최대 80kW최대 80kW최대 80kW최대 10*2kW최대 10*2kW

 


냉각 및 난방 시스템(WTD 시리즈)

(마이크로 채널/튜브 리액터 전문)

온도 제어 범위: -70°C ~ +300°C

마이크로 채널에 특화된 설계(작은 액체 보유 용량, 강력한 열 교환 용량, 순환 시스템 고압 강하)

 

온도 범위 -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
냉각 용량up to 7.5kWup to 5.5kW최대 50kW

 


Cooling and Heating Systems (TES series)

Temperature Control Range: -85°C ~ +250°C

Temp Control Accuracy: ± 0.3°C

 

 

온도 범위 -45°C ~ +250°C 시리즈 -85°C ~ +200°C 시리즈 -60°C ~ +200°C 시리즈
냉각 용량최대 25kW최대 25kW최대 60kW

 


Cooling and Heating Machines (LTS series)

온도 제어 범위: -80°C ~ +80°C

It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.

 

 

온도 범위 -20°C ~ +80°C 시리즈 -45°C ~ +80°C 시리즈 -60°C ~ +80°C 시리즈 -80°C ~ +80°C 시리즈
흐름 제어7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min

 


냉각 및 난방 서큘레이터

온도 제어 범위: -45°C ~ +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

온도 범위 -25°C ~ +200°C 시리즈 -45°C ~ +250°C 시리즈
냉각 용량최대 15kW최대 15kW

 


난방 서큘레이터

온도 제어 범위: +50°C ~ +300°C

참고: UC 시리즈는 열전달 매체의 온도를 제어할 수 있습니다. UST 시리즈는 열 전달 매체의 온도를 제어할 수 있을 뿐만 아니라 반응 물질의 온도도 제어할 수 있습니다.

온도 범위 +50°C ~ +200°C  (UC series) +50°C ~ +300°C(UC 시리즈) +50°C ~ +300°C(UST 시리즈)
난방 용량최대 38kW최대 200kW최대 95kW

 


TCU 멀티 리액터 온도 제어 시스템

온도 제어 범위: -120°C ~ +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

온도 범위 -45°C ~ +250°C 시리즈 -120°C ~ +250°C 시리즈맞춤형 온도 제어 시스템RT+10°C ~ +135°C
난방 용량최대 80kW최대 80kW사용자 지정up to 300kW

 

저작권 정보는 lneya-online.com에 귀속되며 자세한 내용은 이메일로 문의하시기 바랍니다: lilia@lneya.com

또는 아래의 WhatsApp 또는 WeChat QR 코드를 스캔하여 문의하세요. 

왓츠앱 위챗

스캔

이전: 다음:

购物车

X

我的足迹

X
키워드: 키워드병에 담긴 기쁨 물 냉각기