Influence of Chiller Evaporator on Refrigeration System

분류업계 뉴스 253

Influence of Chiller Evaporator on Refrigeration System

 

According to different models, the selection of evaporators is also different. For example, tank-type chillers use water tank coil evaporators; open chillers and screw chillers use shell-and-tube evaporators; for durable Acid-base chiller, you can choose titanium tube evaporator or stainless steel plate exchanger. There are many options for a chiller, and of course, it can be customized according to user needs.cryogenic water chiller

The temperature condition of the evaporator of the chiller: under normal circumstances, the outer surface of the evaporator is very cold, and the condensed water drops continuously, and the temperature of the inlet and outlet air is relatively high, usually Δt can be 12~14°C. In abnormal conditions, the evaporator The surface is not too cool, there is not much dew, or there is no condensation, the sound of refrigerant flowing can be heard very loudly, and the temperature difference between the inlet and outlet air is small. The reason is that the amount of refrigerant is insufficient, or the opening degree of the expansion valve is small.

The factors that affect the evaporation temperature of industrial chillers are as follows:

Oil in the evaporator pipeline: Under normal circumstances, due to the mutual solubility of lubricating oil and Freon, no oil film will be formed on the surface of the heat exchanger, and the thermal resistance of the oil film can be ignored. Oil, to prevent the generation of oil film.

The air filter is clogged: the filter must be replaced regularly to ensure the circulating air volume required by the air conditioner. Blockage of dry filter: In order to ensure the normal circulation of the refrigerant, the refrigeration system must be kept clean and dry. If there are impurities in the system, it will cause blockage of the dry filter, and it will be difficult to supply liquid to the system, which will affect the cooling effect. If the refrigerant is too little, add Freon.

우리는 온도 제어 장비의 전문 제조업체로 맞춤형 서비스를 지원합니다. 문의하기 자세한 내용을 확인하세요!

 


자동차 테스트 냉각기

온도 제어 범위: -40°C ~ +100°C

 

제품 보기

 


반도체 테스트 냉각기

온도 제어 범위: -85°C ~ +250°C

 

제품 보기

 


산업용 냉장고

온도 제어 범위: -150°C ~ -10°C

 

제품 보기

 

저작권 정보는 lneya-online.com에 귀속되며 자세한 내용은 이메일로 문의하시기 바랍니다: lilia@lneya.com

또는 아래의 WhatsApp 또는 WeChat QR 코드를 스캔하여 문의하세요. 

왓츠앱 위챗

스캔

이전: 다음:

购物车

X

我的足迹

X
키워드: 키워드병에 담긴 기쁨 물 냉각기