The application of laboratory circulating thermostat in glass reactor is crucial, which directly affects the efficiency of chemical reactions, the quality of products and the safety of experiments or production.

The core functions and advantages of laboratory circulating thermostat:

1. Precise temperature control: Through high-precision temperature sensors and intelligent control systems, the temperature in the glass reactor is accurately adjusted within the set range to meet the strict temperature requirements of different chemical reactions.

2. Fast response: The heating and cooling components must have fast response characteristics and can reach or adjust to the target temperature in a short time, especially in the reaction process that requires rapid heating and cooling.

3. Uniformity: The heating and cooling system should be designed with a good heat transfer mechanism to ensure uniform temperature in all parts of the reactor and avoid local overheating or overcooling, which is crucial to ensure the stability of the reaction and the consistency of the product.

4. Safe and reliable: Integrate multiple safety protection measures, such as over-temperature alarm, pressure control and leakage protection, to ensure the safety of operators and equipment.

5. High energy efficiency ratio: Select high-efficiency heating and cooling components to reduce energy consumption and reduce long-term operating costs.

 

Laboratory Circulating Thermostat for Glass Reactors

 

Specific considerations for glass reactors in laboratory circulating thermostats:

Reaction type: Heating and cooling power are selected based on whether the reaction is exothermic or endothermic and the optimal temperature range of the reaction.

Material properties: Consider the specific heat capacity, boiling point, crystallization point, etc. of the material to ensure that the system can effectively handle the thermal properties of the material.

Reaction scale: Select a system with corresponding heating and cooling capacity based on the volume of the reactor and the scale of the production batch.

Environmental factors: Consider the ambient temperature of the laboratory or factory location, especially in extreme climate conditions, where additional cooling or heating compensation may be required.

For the integration of heating and cooling systems for glass reactors, it is recommended to work closely with professional suppliers to customize solutions based on specific experimental or production needs. If you are planning or upgrading your glass reactor supporting system, please provide more details and I will provide more targeted professional advice and suggestions.

 


 

We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.

We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.

request

Email: lilia@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 

scan

 

1.Cooling and Heating Systems


Cooling and Heating Systems (SUNDI series)

(Custom Designs)

  • Temperature range: -120℃ ~ +350℃
  • High-precision, intelligent temperature control
  • Cooling capacity: 0.5kW ~ 1200kW
  • Fully closed system to extend the service life of thermal fluid
  • Each device is load tested for more than 12 hours

 

Temperature range -10 ~ +150°C series -25 ~ +200°C series -25 ~ +300°C series -45 ~ +250°C series -45 ~ +300°C series -60 ~ +250°C series -60 ~ +300°C series -70 ~ +250°C series -80 ~ +250°C series-90 ~ +250°C series -100 ~ +100°C series
Cooling Capacity1.5 ~ 15kW1 ~ 200kW1 ~ 200kW0.45 ~ 200kW0.9 ~ 25kW0.25 ~ 60kW0.75 ~ 25kW0.4 ~ 15kW0.3 ~ 80kW0.2 ~ 80kW0.45 ~ 80kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


Cooling and Heating Circulators

(Custom Designs)

  • Temperature range: -45℃ ~ +250℃
  • Emerson Copeland compressor, reliable quality
  • Self-diagnosis function, multiple safety protection devices
  • Fully closed system to extend the service life of thermal fluid
  • Each device is load tested for more than 12 hours

 

Temperature range -25°C ~ +200°C series -45°C ~ +250°C series
Cooling Capacity1 ~ 15kW0.25 ~ 15kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


Cooling and Heating Systems (WTD series)

(Custom Designs)

  • (Micro channel / tube reactors specialized)
  • Temperature range: -70℃ ~ +300℃
  • High-performance circulation pump, more stable temperature control effect
  • Wide temperature range to meet the needs of more industries
  • Each device is load tested for more than 12 hours

 

Temperature range -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Cooling Capacity1.1 ~ 7.5kW1.5 ~ 5.5kW11 ~ 50kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


TCU Multi-reactors Temperature Control System

(Custom Designs)

  • Temperature range: -120℃ ~ +250℃
  • Sealed, repeatable temperature control
  • Built-in electric heating thermal oil auxiliary system
  • Add cold and heat source heat exchange modules according to needs
  • Each device is load tested for more than 12 hours

 

Temperature range -45°C ~ +250°C series -120°C ~ +250°C seriesCustomized Temperature Control SystemRT+10°C ~ +135°C
Heating Capacity25 ~ 80kW25 ~ 80kWCustom25 ~ 300kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 

 

2.Cooling Chillers


low temperature chiller

Low Temperature/Cryogenic Chillers (Water Cooled)

(Custom Designs)

  • Temperature range: -150℃ ~ -5℃
  • International brand compressor, high cooling efficiency
  • Secondary subcooling technology, fast cooling speed
  • Automated control and operation, efficient and energy-saving
  • Each device is load tested for more than 12 hours

Six product series

Temperature range -25°C ~ -5°C -45°C ~ -10°C -60°C ~ -10°C -80°C ~ -30°C-110°C ~ -50°C -150°C ~ -110°C
Cooling Capacity12kW…360kW6kW…180kW6kW…180kW4kW…180kW2kW…120kW2.5kW…11kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


recirculating chiller

Recirculating Chiller/Refrigerated Circulator (Air Cooled)

(Custom Designs)

  • Temperature range: -120℃ ~ +30℃
  • International brand compressor, cascade refrigeration technology
  • Use ethylene glycol or a mixture of ethylene glycol and water
  • Fully sealed design to ensure the purity of the medium
  • Each device is load tested for more than 12 hours

Five product series

Temperature range -25°C ~ +30°C -45°C ~ +30°C -60°C ~ -20°C -80°C ~ -20°C -120°C ~ -70°C
Cooling Capacity0.8kW…30kW0.75kW…12kW0.4kW…6kW0.2kW…6kW0.3kW…5kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


 

Precision Chillers / Small ChillersSmall Chillers / Mini Chillers

(Custom Designs)

  • Temperature range: -18℃ ~ +35℃
  • International brand compressor, stable performance
  • Microcomputer controller, adjustment unit 0.1℃
  • Energy saving, high temperature control accuracy
  • Each device is load tested for more than 12 hours

Two product series

Temperature range -18°C ~ +30°C +5°C ~ +35°C
Cooling Capacity0.35 ~ 0.9kW1.8kW…50kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


SEMICONDUCTOR CHILLER

 

High Temperature Chillers

(Custom Designs)

  • Temperature range: -100℃ ~ +80℃
  • International brand compressors and other accessories
  • Fully sealed design to ensure the purity of the medium
  • PLC programmable controller
  • Each device is load tested for more than 12 hours

Five product series

Temperature range +5°C ~ +40°C -25°C ~ +40°C -45°C ~ +40°C -80°C ~ +80°C -100°C ~ +80°C
Cooling Capacity6kW…40kW2kW…15kW1kW…8kW0.kW…3kW1.5kW…3kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Latest News
Request a Quote
Name
Email Address
Phone
Company
Message

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller