Laboratory Heater Chiller
Laboratory Heater Chiller provides users with a liquid environment with controlled heating and cooling, uniform and constant temperature when working. It is often used in reaction kettles to control the heat demand and exothermic process during the reaction process. It can accurately and linearly control the temperature of the materials in the kettle, and program control can be selected. Mode, the temperature difference of heat transfer medium and material can also be set, and it can also be used for heating and cooling of other equipment separately.
First, introduction of Laboratory Heater Chiller:
Laboratory Heater Chiller is mainly composed of compressor, condenser, filter, expansion valve, heat exchanger, evaporator, circulating pump, display screen, liquid level indicator, electrical cabinet, motor, etc., and the heat transfer medium is driven by the pump ( Usually water or oil) from the oil tank with built-in heater to the temperature control equipment, and from the temperature control equipment back to the oil tank. The controller adjusts the temperature of the thermal fluid to adjust the temperature of the temperature control device according to the temperature of the thermal fluid measured by the temperature sensor or the internal temperature of the temperature control device.
Second, precautions for use of Laboratory Heater Chiller:
1. Whether it is air-cooled or water-cooled, the temperature control device must be located in an operating environment with enough fresh air, and the space should be large enough.
2. The heat conduction medium pipeline cannot be blocked, and the heat conduction medium pipe should be checked and maintained regularly to avoid material strain and fission.
3. In order to avoid damage to the integrated cooling and heating pipelines, users are using high mineral content, so it is necessary to regularly use water treatment chemicals to clean the dirt on the pipelines.
4. When not in use, please be sure to disconnect the cooling water connection pipe, clean up the remaining cooling water/heat transfer oil in the pipe, pack it and store it in a dry place.
The Laboratory Heater Chiller adopts a fully enclosed pipeline design to reduce the demand for heat transfer fluid while improving the heat utilization rate of the system to achieve rapid temperature rise and fall. The heat transfer medium in the expansion vessel does not participate in circulation, which can reduce the risk of heat transfer medium absorbing moisture and volatilization during operation.
Dynamic Temperature Control Systems (Support Customization)
Cooling and Heating Systems (SUNDI series) (Custom Designs)
Temperature Control Range: -120°C to +350°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperature range | -10 ~ +150°C series | -25 ~ +200°C series | -25 ~ +300°C series | -45 ~ +250°C series | -45 ~ +300°C series | -60 ~ +250°C series | -60 ~ +300°C series | -70 ~ +250°C series | -80 ~ +250°C series | -90 ~ +250°C series | -100 ~ +100°C series | -25 ~ +200°C one machine for two reactors | -40 ~ +200°C one machine for two reactors |
Cooling Capacity | 1.5 ~ 15kW | 1 ~ 200kW | 1 ~ 200kW | 0.45 ~ 200kW | 0.9 ~ 25kW | 0.25 ~ 60kW | 0.75 ~ 25kW | 0.4 ~ 15kW | 0.3 ~ 80kW | 0.2 ~ 80kW | 0.45 ~ 80kW | up to 10*2kW | up to 10*2kW |
Cooling and Heating Systems (WTD series) (Custom Designs)
(Micro channel / tube reactors specialized)
Temperature Control Range: -70°C to +300°C
Specialized design for micro channel (small liquid holding capacity, strong heat exchange capacity, circulation system high pressure drop)
Temperature range | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C |
Cooling Capacity | 1.1 ~ 7.5kW | 1.5 ~ 5.5kW | 11 ~ 50kW |
Cooling and Heating Systems (TES series) (Custom Designs)
Temperature Control Range: -85°C ~ +250°C
Temp Control Accuracy: ± 0.3°C
Temperature range | -45°C ~ +250°C series | -85°C ~ +200°C series | -60°C ~ +200°C series |
Cooling Capacity | 0.3 ~ 25kW | 0.25 ~ 25kW | 3 ~ 60kW |
Cooling and Heating Machines (LTS series) (Custom Designs)
Temperature Control Range: -80°C to +80°C
It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.
Temperature range | -20°C ~ +80°C series | -45°C ~ +80°C series | -60°C ~ +80°C series | -80°C ~ +80°C series |
Flow Control | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min |
Cooling and Heating Circulators (Custom Designs)
Temperature Control Range: -45°C to +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperature range | -25°C ~ +200°C series | -45°C ~ +250°C series |
Cooling Capacity | 1 ~ 15kW | 0.25 ~ 15kW |
Heating Circulators (Custom Designs)
Temperature Control Range: +50°C to +300°C
Note: UC series can control the temperature of heat transfer medium. UST series can not only control the temperature of the heat transfer medium, but also control the temperature of the reaction material.
Temperature range | +50°C ~ +170°C (UC series) | +50°C ~ +300°C (UC series) | +50°C ~ +300°C (UST series) |
Heating Capacity | 5.5 ~ 15kW | 3.5 ~ 130kW | 3.5 ~ 95kW |
TCU Multi-reactors Temperature Control System (Custom Designs)
Temperature Control Range: -120°C to +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperature range | -45°C ~ +250°C series | -120°C ~ +250°C series | Customized Temperature Control System | RT+10°C ~ +135°C |
Heating Capacity | 25 ~ 80kW | 25 ~ 80kW | Custom | 25 ~ 300kW |