Laboratory Heating and Cooling Units for Jacketed Reactors
When choosing the right heating and cooling device for your lab jacketed reactor, you need to focus on the following aspects to ensure efficient and accurate temperature control:
1. Compatibility and design: Choose a device that can perfectly interface with your jacketed reactor to ensure good heat exchange performance. The jacket layer should be designed to facilitate the circulation of heating media (such as hot water, oil or hot and cold gas).
2. Temperature control range and accuracy: According to the experimental requirements, determine the temperature range that the device needs to cover. Usually, industrial applications range from -80°C to +250°C, and the control accuracy must reach ±0.5°C or higher.
3. Heating and cooling capacity: Evaluate the capacity of the reactor, the specific heat capacity of the material, and the desired heating/cooling rate, and select heating elements and cooling capacity with corresponding power to ensure that the set temperature is quickly reached and maintained.
4. Control system: Modern PID controllers or PLC systems can achieve precise temperature control and program setting, support remote monitoring and data recording, and improve the automation level and traceability of experiments.
5. Safety measures: including over-temperature protection, pressure control, low liquid level alarm, etc., to ensure safe and worry-free experimental operation.
6. Material and corrosion resistance: Corrosion-resistant materials, such as stainless steel 316L, should be used for parts in contact with the medium to meet the needs of different chemical media.
7. Energy efficiency and sustainability: Consider the energy efficiency level of the equipment and choose energy-saving products to reduce operating costs and environmental impact.
To obtain specific product recommendations, more detailed information is required, such as budget range, specific space limitations of the laboratory, or any specific experimental requirements. Please provide this additional information and I will provide you with more specific suggestions.
We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.
We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.
Email: lilia@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
Cooling and Heating Systems (SUNDI series)
- Temperature range: -120℃ ~ +350℃
- High-precision, intelligent temperature control
- Cooling capacity: 0.5kW ~ 1200kW
- Fully closed system to extend the service life of thermal fluid
- Each device is load tested for more than 12 hours
Temperature range | -10 ~ +150°C series | -25 ~ +200°C series | -25 ~ +300°C series | -45 ~ +250°C series | -45 ~ +300°C series | -60 ~ +250°C series | -60 ~ +300°C series | -70 ~ +250°C series | -80 ~ +250°C series | -90 ~ +250°C series | -100 ~ +100°C series | ||
Cooling Capacity | 1.5 ~ 15kW | 1 ~ 200kW | 1 ~ 200kW | 0.45 ~ 200kW | 0.9 ~ 25kW | 0.25 ~ 60kW | 0.75 ~ 25kW | 0.4 ~ 15kW | 0.3 ~ 80kW | 0.2 ~ 80kW | 0.45 ~ 80kW | ||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Cooling and Heating Circulators
- Temperature range: -45℃ ~ +250℃
- Emerson Copeland compressor, reliable quality
- Self-diagnosis function, multiple safety protection devices
- Fully closed system to extend the service life of thermal fluid
- Each device is load tested for more than 12 hours
Temperature range | -25°C ~ +200°C series | -45°C ~ +250°C series | |||||||
Cooling Capacity | 1 ~ 15kW | 0.25 ~ 15kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Cooling and Heating Systems (WTD series)
- (Micro channel / tube reactors specialized)
- Temperature range: -70℃ ~ +300℃
- High-performance circulation pump, more stable temperature control effect
- Wide temperature range to meet the needs of more industries
- Each device is load tested for more than 12 hours
Temperature range | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C | ||||||
Cooling Capacity | 1.1 ~ 7.5kW | 1.5 ~ 5.5kW | 11 ~ 50kW | ||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
TCU Multi-reactors Temperature Control System
- Temperature range: -120℃ ~ +250℃
- Sealed, repeatable temperature control
- Built-in electric heating thermal oil auxiliary system
- Add cold and heat source heat exchange modules according to needs
- Each device is load tested for more than 12 hours
Temperature range | -45°C ~ +250°C series | -120°C ~ +250°C series | Customized Temperature Control System | RT+10°C ~ +135°C | |||||
Heating Capacity | 25 ~ 80kW | 25 ~ 80kW | Custom | 25 ~ 300kW | |||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |