Search Search all

Laboratory Heating and Cooling Units for Jacketed Reactors

ClassificationIndustry News 59 0

Laboratory Heating and Cooling Units for Jacketed Reactors

 

When choosing the right heating and cooling device for your lab jacketed reactor, you need to focus on the following aspects to ensure efficient and accurate temperature control:

1. Compatibility and design: Choose a device that can perfectly interface with your jacketed reactor to ensure good heat exchange performance. The jacket layer should be designed to facilitate the circulation of heating media (such as hot water, oil or hot and cold gas).

2. Temperature control range and accuracy: According to the experimental requirements, determine the temperature range that the device needs to cover. Usually, industrial applications range from -80°C to +250°C, and the control accuracy must reach ±0.5°C or higher.

 

Laboratory Heating and Cooling Units for Jacketed Reactors

3. Heating and cooling capacity: Evaluate the capacity of the reactor, the specific heat capacity of the material, and the desired heating/cooling rate, and select heating elements and cooling capacity with corresponding power to ensure that the set temperature is quickly reached and maintained.

4. Control system: Modern PID controllers or PLC systems can achieve precise temperature control and program setting, support remote monitoring and data recording, and improve the automation level and traceability of experiments.

5. Safety measures: including over-temperature protection, pressure control, low liquid level alarm, etc., to ensure safe and worry-free experimental operation.

6. Material and corrosion resistance: Corrosion-resistant materials, such as stainless steel 316L, should be used for parts in contact with the medium to meet the needs of different chemical media.

7. Energy efficiency and sustainability: Consider the energy efficiency level of the equipment and choose energy-saving products to reduce operating costs and environmental impact.

To obtain specific product recommendations, more detailed information is required, such as budget range, specific space limitations of the laboratory, or any specific experimental requirements. Please provide this additional information and I will provide you with more specific suggestions.

 


 

We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.

We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.

request

Email: lilia@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 

scan

 


Cooling and Heating Systems (SUNDI series)

(Custom Designs)

  • Temperature range: -120℃ ~ +350℃
  • High-precision, intelligent temperature control
  • Cooling capacity: 0.5kW ~ 1200kW
  • Fully closed system to extend the service life of thermal fluid
  • Each device is load tested for more than 12 hours

 

Temperature range -10 ~ +150°C series -25 ~ +200°C series -25 ~ +300°C series -45 ~ +250°C series -45 ~ +300°C series -60 ~ +250°C series -60 ~ +300°C series -70 ~ +250°C series -80 ~ +250°C series-90 ~ +250°C series -100 ~ +100°C series
Cooling Capacity1.5 ~ 15kW1 ~ 200kW1 ~ 200kW0.45 ~ 200kW0.9 ~ 25kW0.25 ~ 60kW0.75 ~ 25kW0.4 ~ 15kW0.3 ~ 80kW0.2 ~ 80kW0.45 ~ 80kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


Cooling and Heating Circulators

(Custom Designs)

  • Temperature range: -45℃ ~ +250℃
  • Emerson Copeland compressor, reliable quality
  • Self-diagnosis function, multiple safety protection devices
  • Fully closed system to extend the service life of thermal fluid
  • Each device is load tested for more than 12 hours

 

Temperature range -25°C ~ +200°C series -45°C ~ +250°C series
Cooling Capacity1 ~ 15kW0.25 ~ 15kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


Cooling and Heating Systems (WTD series)

(Custom Designs)

  • (Micro channel / tube reactors specialized)
  • Temperature range: -70℃ ~ +300℃
  • High-performance circulation pump, more stable temperature control effect
  • Wide temperature range to meet the needs of more industries
  • Each device is load tested for more than 12 hours

 

Temperature range -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Cooling Capacity1.1 ~ 7.5kW1.5 ~ 5.5kW11 ~ 50kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


TCU Multi-reactors Temperature Control System

(Custom Designs)

  • Temperature range: -120℃ ~ +250℃
  • Sealed, repeatable temperature control
  • Built-in electric heating thermal oil auxiliary system
  • Add cold and heat source heat exchange modules according to needs
  • Each device is load tested for more than 12 hours

 

Temperature range -45°C ~ +250°C series -120°C ~ +250°C seriesCustomized Temperature Control SystemRT+10°C ~ +135°C
Heating Capacity25 ~ 80kW25 ~ 80kWCustom25 ~ 300kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Latest News
Request a Quote
Name
Email Address
Phone
Company
Message

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller