Search Search all

Laboratory High and Low Temperature Circulation Device for Jacketed Reactor

ClassificationIndustry News 59 0

Laboratory High and Low Temperature Circulation Device for Jacketed Reactor

 

When the laboratory high and low temperature circulation device is used in a jacketed reactor, the key is to ensure that the device can accurately control the temperature range and adapt to the rapid temperature change and highly stable temperature environment required for the experiment.

 

Laboratory High and Low Temperature Circulation Device for Jacketed Reactor

 

The following are the main factors to consider when choosing a laboratory high and low temperature circulation device:

1. Temperature range: Confirm whether the minimum and maximum operating temperatures of the device meet your experimental requirements. Usually, such equipment needs to cover the range from low temperature (such as -80℃) to high temperature (such as 200℃).

2. Temperature control accuracy: Choose a device with a high-precision temperature control system (such as ±0.1℃), which is particularly important for rigorous chemical synthesis or material research.

3. Cycle rate and uniformity: A good cycle design can ensure that the temperature reaches the set value quickly and is evenly distributed in the jacket, reducing local overheating or overcooling.

4. Safety features: Including over-temperature protection, pressure control and alarm systems to ensure the safety of operators and equipment.

5. User interface and control: Friendly operation interface, support programming control, can preset temperature change programs according to the experimental process, and improve experimental efficiency.

6. Energy consumption and environmental protection: Consider the energy efficiency ratio of the device, choose energy-saving products to reduce operating costs, and pay attention to environmental standards, such as using environmentally friendly refrigerants.

If you can provide the specific model and volume of your laboratory jacketed reactor, as well as the specific requirements for temperature control in the experiment (such as temperature range, heating or cooling speed, etc.), I will be able to recommend a high and low temperature circulation device model that better meets your actual needs or provide customized suggestions.

 


 

We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.

We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.

request

Email: lilia@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 

scan

 


Cooling and Heating Systems (SUNDI series)

(Custom Designs)

  • Temperature range: -120℃ ~ +350℃
  • High-precision, intelligent temperature control
  • Cooling capacity: 0.5kW ~ 1200kW
  • Fully closed system to extend the service life of thermal fluid
  • Each device is load tested for more than 12 hours

 

Temperature range -10 ~ +150°C series -25 ~ +200°C series -25 ~ +300°C series -45 ~ +250°C series -45 ~ +300°C series -60 ~ +250°C series -60 ~ +300°C series -70 ~ +250°C series -80 ~ +250°C series-90 ~ +250°C series -100 ~ +100°C series
Cooling Capacity1.5 ~ 15kW1 ~ 200kW1 ~ 200kW0.45 ~ 200kW0.9 ~ 25kW0.25 ~ 60kW0.75 ~ 25kW0.4 ~ 15kW0.3 ~ 80kW0.2 ~ 80kW0.45 ~ 80kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


Cooling and Heating Circulators

(Custom Designs)

  • Temperature range: -45℃ ~ +250℃
  • Emerson Copeland compressor, reliable quality
  • Self-diagnosis function, multiple safety protection devices
  • Fully closed system to extend the service life of thermal fluid
  • Each device is load tested for more than 12 hours

 

Temperature range -25°C ~ +200°C series -45°C ~ +250°C series
Cooling Capacity1 ~ 15kW0.25 ~ 15kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


Cooling and Heating Systems (WTD series)

(Custom Designs)

  • (Micro channel / tube reactors specialized)
  • Temperature range: -70℃ ~ +300℃
  • High-performance circulation pump, more stable temperature control effect
  • Wide temperature range to meet the needs of more industries
  • Each device is load tested for more than 12 hours

 

Temperature range -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Cooling Capacity1.1 ~ 7.5kW1.5 ~ 5.5kW11 ~ 50kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


TCU Multi-reactors Temperature Control System

(Custom Designs)

  • Temperature range: -120℃ ~ +250℃
  • Sealed, repeatable temperature control
  • Built-in electric heating thermal oil auxiliary system
  • Add cold and heat source heat exchange modules according to needs
  • Each device is load tested for more than 12 hours

 

Temperature range -45°C ~ +250°C series -120°C ~ +250°C seriesCustomized Temperature Control SystemRT+10°C ~ +135°C
Heating Capacity25 ~ 80kW25 ~ 80kWCustom25 ~ 300kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Request a Quote
Name
Email Address
Phone
Company
Please fill in your requirements
Request A Quote

loading...

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller