Laboratory High and Low Temperature Circulation Device for Jacketed Reactor
When the laboratory high and low temperature circulation device is used in a jacketed reactor, the key is to ensure that the device can accurately control the temperature range and adapt to the rapid temperature change and highly stable temperature environment required for the experiment.
The following are the main factors to consider when choosing a laboratory high and low temperature circulation device:
1. Temperature range: Confirm whether the minimum and maximum operating temperatures of the device meet your experimental requirements. Usually, such equipment needs to cover the range from low temperature (such as -80℃) to high temperature (such as 200℃).
2. Temperature control accuracy: Choose a device with a high-precision temperature control system (such as ±0.1℃), which is particularly important for rigorous chemical synthesis or material research.
3. Cycle rate and uniformity: A good cycle design can ensure that the temperature reaches the set value quickly and is evenly distributed in the jacket, reducing local overheating or overcooling.
4. Safety features: Including over-temperature protection, pressure control and alarm systems to ensure the safety of operators and equipment.
5. User interface and control: Friendly operation interface, support programming control, can preset temperature change programs according to the experimental process, and improve experimental efficiency.
6. Energy consumption and environmental protection: Consider the energy efficiency ratio of the device, choose energy-saving products to reduce operating costs, and pay attention to environmental standards, such as using environmentally friendly refrigerants.
If you can provide the specific model and volume of your laboratory jacketed reactor, as well as the specific requirements for temperature control in the experiment (such as temperature range, heating or cooling speed, etc.), I will be able to recommend a high and low temperature circulation device model that better meets your actual needs or provide customized suggestions.
We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.
We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.
Email: lilia@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
Cooling and Heating Systems (SUNDI series)
- Temperature range: -120℃ ~ +350℃
- High-precision, intelligent temperature control
- Cooling capacity: 0.5kW ~ 1200kW
- Fully closed system to extend the service life of thermal fluid
- Each device is load tested for more than 12 hours
Temperature range | -10 ~ +150°C series | -25 ~ +200°C series | -25 ~ +300°C series | -45 ~ +250°C series | -45 ~ +300°C series | -60 ~ +250°C series | -60 ~ +300°C series | -70 ~ +250°C series | -80 ~ +250°C series | -90 ~ +250°C series | -100 ~ +100°C series | ||
Cooling Capacity | 1.5 ~ 15kW | 1 ~ 200kW | 1 ~ 200kW | 0.45 ~ 200kW | 0.9 ~ 25kW | 0.25 ~ 60kW | 0.75 ~ 25kW | 0.4 ~ 15kW | 0.3 ~ 80kW | 0.2 ~ 80kW | 0.45 ~ 80kW | ||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Cooling and Heating Circulators
- Temperature range: -45℃ ~ +250℃
- Emerson Copeland compressor, reliable quality
- Self-diagnosis function, multiple safety protection devices
- Fully closed system to extend the service life of thermal fluid
- Each device is load tested for more than 12 hours
Temperature range | -25°C ~ +200°C series | -45°C ~ +250°C series | |||||||
Cooling Capacity | 1 ~ 15kW | 0.25 ~ 15kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Cooling and Heating Systems (WTD series)
- (Micro channel / tube reactors specialized)
- Temperature range: -70℃ ~ +300℃
- High-performance circulation pump, more stable temperature control effect
- Wide temperature range to meet the needs of more industries
- Each device is load tested for more than 12 hours
Temperature range | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C | ||||||
Cooling Capacity | 1.1 ~ 7.5kW | 1.5 ~ 5.5kW | 11 ~ 50kW | ||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
TCU Multi-reactors Temperature Control System
- Temperature range: -120℃ ~ +250℃
- Sealed, repeatable temperature control
- Built-in electric heating thermal oil auxiliary system
- Add cold and heat source heat exchange modules according to needs
- Each device is load tested for more than 12 hours
Temperature range | -45°C ~ +250°C series | -120°C ~ +250°C series | Customized Temperature Control System | RT+10°C ~ +135°C | |||||
Heating Capacity | 25 ~ 80kW | 25 ~ 80kW | Custom | 25 ~ 300kW | |||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |