Laboratory Refrigeration and Heating Thermostats for Reactors
Laboratory refrigeration and heating thermostats play a vital role when used with reactors to ensure that chemical reactions are carried out under strictly controlled temperature conditions. These devices are designed to meet the high temperature control requirements of reactors and have the following features and advantages:
Features of laboratory refrigeration and heating thermostats
1. Tight temperature matching: Ability to provide tight temperature control according to the specific requirements of the reactor to keep the temperature of the reaction medium constant, even when a large amount of heat is released or absorbed during the reaction.
2. Fast response: With the ability to heat and cool quickly, quickly reach the set temperature and effectively respond to temperature fluctuations during the process, reduce reaction time, and improve the efficiency of experiments or production.
3. Corrosion-resistant design: Since the reactor may involve strong acids, strong alkalis or corrosive media, the matching refrigeration and heating thermostats are usually made of corrosion-resistant materials to ensure long-term stable operation.
4. Safety control: Integrated multiple safety protection functions, such as over-temperature alarm, pressure protection, leakage protection, etc., to ensure safe experimental operation.
5. Continuous operation capability: Designed for long-term uninterrupted operation, suitable for continuous reaction processes that require long-term temperature control.
Advantages of laboratory refrigeration and heating thermostats
1. Improve reaction efficiency and yield: Accurate temperature control can optimize chemical reaction paths, accelerate reaction rates, and increase product yield and purity.
2. Enhance experimental reproducibility: A stable temperature environment helps the repeatability of experimental results, which is particularly important for scientific research and process development.
3. Easy operation and monitoring: Modern control panels and remote monitoring functions make operation more convenient, and researchers can adjust and monitor reaction status at any time.
4. Energy saving and emission reduction: High-efficiency design reduces energy consumption, which is in line with the concept of green laboratories and sustainable development.
In short, laboratory refrigeration and heating thermostats provide accurate, safe, and efficient temperature control solutions for reactors, and are indispensable equipment for high-quality scientific research and industrial production.
We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.
We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.
Email: lilia@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
1.Cooling and Heating Systems
Cooling and Heating Systems (SUNDI series)
- Temperature range: -120℃ ~ +350℃
- High-precision, intelligent temperature control
- Cooling capacity: 0.5kW ~ 1200kW
- Fully closed system to extend the service life of thermal fluid
- Each device is load tested for more than 12 hours
Temperature range | -10 ~ +150°C series | -25 ~ +200°C series | -25 ~ +300°C series | -45 ~ +250°C series | -45 ~ +300°C series | -60 ~ +250°C series | -60 ~ +300°C series | -70 ~ +250°C series | -80 ~ +250°C series | -90 ~ +250°C series | -100 ~ +100°C series | ||
Cooling Capacity | 1.5 ~ 15kW | 1 ~ 200kW | 1 ~ 200kW | 0.45 ~ 200kW | 0.9 ~ 25kW | 0.25 ~ 60kW | 0.75 ~ 25kW | 0.4 ~ 15kW | 0.3 ~ 80kW | 0.2 ~ 80kW | 0.45 ~ 80kW | ||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Cooling and Heating Circulators
- Temperature range: -45℃ ~ +250℃
- Emerson Copeland compressor, reliable quality
- Self-diagnosis function, multiple safety protection devices
- Fully closed system to extend the service life of thermal fluid
- Each device is load tested for more than 12 hours
Temperature range | -25°C ~ +200°C series | -45°C ~ +250°C series | |||||||
Cooling Capacity | 1 ~ 15kW | 0.25 ~ 15kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Cooling and Heating Systems (WTD series)
- (Micro channel / tube reactors specialized)
- Temperature range: -70℃ ~ +300℃
- High-performance circulation pump, more stable temperature control effect
- Wide temperature range to meet the needs of more industries
- Each device is load tested for more than 12 hours
Temperature range | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C | ||||||
Cooling Capacity | 1.1 ~ 7.5kW | 1.5 ~ 5.5kW | 11 ~ 50kW | ||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
TCU Multi-reactors Temperature Control System
- Temperature range: -120℃ ~ +250℃
- Sealed, repeatable temperature control
- Built-in electric heating thermal oil auxiliary system
- Add cold and heat source heat exchange modules according to needs
- Each device is load tested for more than 12 hours
Temperature range | -45°C ~ +250°C series | -120°C ~ +250°C series | Customized Temperature Control System | RT+10°C ~ +135°C | |||||
Heating Capacity | 25 ~ 80kW | 25 ~ 80kW | Custom | 25 ~ 300kW | |||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
2.Cooling Chillers
Low Temperature/Cryogenic Chillers (Water Cooled)
- Temperature range: -150℃ ~ -5℃
- International brand compressor, high cooling efficiency
- Secondary subcooling technology, fast cooling speed
- Automated control and operation, efficient and energy-saving
- Each device is load tested for more than 12 hours
Six product series
Temperature range | -25°C ~ -5°C | -45°C ~ -10°C | -60°C ~ -10°C | -80°C ~ -30°C | -110°C ~ -50°C | -150°C ~ -110°C | |||
Cooling Capacity | 12kW…360kW | 6kW…180kW | 6kW…180kW | 4kW…180kW | 2kW…120kW | 2.5kW…11kW | |||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Recirculating Chiller/Refrigerated Circulator (Air Cooled)
- Temperature range: -120℃ ~ +30℃
- International brand compressor, cascade refrigeration technology
- Use ethylene glycol or a mixture of ethylene glycol and water
- Fully sealed design to ensure the purity of the medium
- Each device is load tested for more than 12 hours
Five product series
Temperature range | -25°C ~ +30°C | -45°C ~ +30°C | -60°C ~ -20°C | -80°C ~ -20°C | -120°C ~ -70°C | ||||
Cooling Capacity | 0.8kW…30kW | 0.75kW…12kW | 0.4kW…6kW | 0.2kW…6kW | 0.3kW…5kW | ||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Small Chillers / Mini Chillers
- Temperature range: -18℃ ~ +35℃
- International brand compressor, stable performance
- Microcomputer controller, adjustment unit 0.1℃
- Energy saving, high temperature control accuracy
- Each device is load tested for more than 12 hours
Two product series
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C | |||||||
Cooling Capacity | 0.35 ~ 0.9kW | 1.8kW…50kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
High Temperature Chillers
- Temperature range: -100℃ ~ +80℃
- International brand compressors and other accessories
- Fully sealed design to ensure the purity of the medium
- PLC programmable controller
- Each device is load tested for more than 12 hours
Five product series
Temperature range | +5°C ~ +40°C | -25°C ~ +40°C | -45°C ~ +40°C | -80°C ~ +80°C | -100°C ~ +80°C | ||||
Cooling Capacity | 6kW…40kW | 2kW…15kW | 1kW…8kW | 0.kW…3kW | 1.5kW…3kW | ||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |