Liquid Immersion Cooling Solution For Data Center
Contact us today for the perfect temperature control solution
As the power of single cabinets in data centers becomes larger and larger, the use of traditional air cooling technology for heat dissipation can no longer meet the fast and efficient cooling requirements of data centers. Under the guidance of the “dual carbon” strategic goal, it has become an inevitable choice to develop low-carbon and efficient cooling technology to solve the technical problems of current data center heat dissipation difficulties and realize the green and low-carbon development of data centers.
Research shows that liquid cooling technology has become an effective solution to solve the cooling problem of data centers. Liquid cooling methods are mainly divided into three types: cold plate liquid cooling, immersion liquid cooling and spray liquid cooling. Compared with traditional air cooling technology, liquid cooling technology has the advantages of efficient cooling, energy saving and consumption reduction, quietness and low noise, system stability, and space saving.
Cold plate liquid cooling is a liquid cooling method in which the heat of the heating device is indirectly transferred to the coolant enclosed in the circulation pipeline through a cold plate (usually made of copper or aluminum), and the heat is taken away by the coolant. Since the coolant is not in direct contact with the electronic equipment, the coolant can be directly made of non-dielectric liquids with high specific heat capacity such as water or ethylene glycol aqueous solution, which has the advantage of strong heat-carrying capacity and can remove more heat from the electronic equipment.
Immersion liquid cooling uses coolant as the heat transfer medium, completely immersing the heating device in the coolant, and performing heat exchange through direct contact. Depending on whether the coolant undergoes phase change, immersion liquid cooling is divided into single-phase immersion liquid cooling and dual-phase immersion liquid cooling.
Compared with dual-phase liquid cooling, single-phase thermal fluid does not undergo phase change, nor does it evaporate in the air like dual-phase thermal fluid, and the cost is an order of magnitude lower. Because single-phase thermal fluid does not evaporate in the air, the cooling system does not have to be sealed to ensure evaporated fluid is recaptured, which also makes it easier to uninstall or replace server components, improving system serviceability. At the same time, single-phase liquid cooling has low requirements on the external environment and can be started from small-scale deployments such as some servers in the data center or edge data centers. It can increase the rack availability rate and make the server operation safer and more stable. Its outstanding energy efficiency can also help reduce the size of data center infrastructure and even eliminate the need for other infrastructure, thereby significantly reducing energy consumption requirements, so it is gradually recognized by the industry.
Email: info@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
Precision Chillers / Small Chillers
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C series |
Cooling Capacity | 0.35 ~ 0.9kW | 1.8 ~ 50kW |
Recirculating Chillers
Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.
Temperature range | -25°C ~ +30°C series | -45°C ~ +30°C series | -60°C ~ -20°C series | -80°C ~ -20°C series | -120°C ~ -70°C series |
Cooling Capacity | 0.8 ~ 30kW | 0.75 ~ 12kW | 0.4 ~ 6kW | 0.2 ~ 6kW | 0.3 ~ 5kW |
Low Temperature Chillers
We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.
Temperature range | -25°C ~ -5°C series | -45°C ~ -10°C series | -60°C ~ -10°C series | -80°C ~ -30°C series | -110°C ~ -50°C series | -150°C ~ -110°C series |
Cooling Capacity | 12 ~ 360kW | 6 ~ 180kW | 6 ~ 180kW | 4 ~ 180kW | 2 ~ 120kW | 2.5 ~ 11kW |
Temperature simulation for vehicle quality test: battery life test, fuel injector/motor test bench, airbag test, component test bench, etc.
Suitable for precise temperature control of electronic components. In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing and other environmental testing simulations.
Liquid Cooling For Battery Energy Storage Systems
Types | For Converting Station | For Energy Storage Battery | For Charging Station |
Cooling Capacity | 45kW | 5 ~ 8.5kW | 4kW |
ZLFQ Series
Coolant Distribution Unit
Liquid cooling equipment is suitable for semiconductor testing, electronic equipment constant temperature testing, cooling server supporting infrastructure, and other fluid temperature control places.
Temperature range | +5°C ~ +35°C | +5°C ~ +35°C |
Cooling Capacity | 15 ~ 150kW | 200 ~ 500kW |
MD Thermal Chucks Series
It is used for testing RF devices and high-density power devices (IGBTs and MOSFETs), and can also be used for rapid cooling of laboratory flat panels (plasma, biological products, batteries), etc.
Temperature range | -75°C ~ +225°C |
Temperature accuracy | ±0.1℃ |
Screw Chillers (Custom Designs)
Low temperature screw chillers and room temperature screw chillers
Temperature range | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Cooling Capacity | 107 ~ 1027kW (Single Compressor) | 299 ~ 2134kW (Dual Compressor) | 98 ~ 934kW (Single Compressor) | 272 ~ 1940kW (Dual Compressor) | 48 ~ 467kW (Single Compressor) | 51 ~ 497kW (Single Compressor) |