Low Temperature Chillers for Botanical Extraction
Contact us today for the perfect temperature control solution
Botanical extraction is rich and diverse. At present, more than 300 kinds have been extracted in industry. It is a very important intermediate product with a wide range of applications. It can be used not only as pharmaceutical raw materials, but also in health products, nutritional supplements, food additives, etc. Cosmetics and other industries.
The flowers, branches and leaves of plants contain a large number of components that are useful to the human body, especially the volatile aromatic components such as monoterpenes, monoterpene alcohols, monoterpene alcohols, etc., which can be widely used in beauty and health care. However, currently Only professional production companies can process and extract.
The wall cavity increases the cooling area of the distilled gas so that it can fully contact the cooling surface. The essential oil components in the gas can be condensed by the cooling liquid in the inner cavity. In this way, most of the essential oil changes from gas to liquid and is discharged, thus preventing The essential oil is discharged with the gas, which avoids waste of raw materials and air pollution, and speeds up the condensation of essential oil components.
The new low-temperature chiller provides a plant essential oil cooling circulating water device, which can condense the essential oil components of the gas, prevent the essential oil components from being discharged with the gas, save raw materials, and improve production efficiency.
Key features of Low Temperature Chillers for Botanical Extraction:
1. Optional PLC intelligent temperature controller with temperature control accuracy of ±0.5℃;
2. Large cooling capacity, among which models with 2 to 500KW cooling capacity are available;
3. The water outlet pressure is large and can be used by customers with relatively high water outlet pressure requirements;
4. High and low pressure monitoring of the refrigeration system to facilitate users to understand the system operation;
5. Comes with compressor overheating protection, overcurrent protection, high and low pressure protection, phase sequence/phase loss protection, and exhaust overheating protection.
We provide complete temperature control systems design and manufacturing. From standard models to complete customized products up to 900 tons. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.
We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.
Email: info@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
Recirculating Chillers / Refrigerated Circulator
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -25°C ~ +30°C series | -45°C ~ +30°C series | -60°C ~ -20°C series | -80°C ~ -20°C series | -120°C ~ -70°C series | ||||
Cooling Capacity | 0.8 ~ 30kW | 0.75 ~ 12kW | 0.4 ~ 6kW | 0.2 ~ 6kW | 0.3 ~ 5kW | ||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Water Chillers / Small Chillers
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C series | |||||||
Cooling Capacity | 0.35 ~ 0.9kW | 1.8 ~ 50kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Low Temperature Chillers
We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.
Temperature range | -25°C ~ -5°C series | -45°C ~ -10°C series | -60°C ~ -10°C series | -80°C ~ -30°C series | -110°C ~ -50°C series | -150°C ~ -110°C series | |||
Cooling Capacity | 12 ~ 360kW | 6 ~ 180kW | 6 ~ 180kW | 4 ~ 180kW | 2 ~ 120kW | 2.5 ~ 11kW | |||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Cooling and Heating Chillers
Temperature Control Range: -120°C to +350°C
cooling and heating thermostat, widely used in various industry.
Temperature range | -10 ~ +150°C series | -25 ~ +200°C series | -25 ~ +300°C series | -45 ~ +250°C series | -45 ~ +300°C series | -60 ~ +250°C series | -60 ~ +300°C series | -70 ~ +250°C series | -80 ~ +250°C series | -90 ~ +250°C series | -100 ~ +100°C series | ||
Cooling Capacity | 1.5 ~ 15kW | 1 ~ 200kW | 1 ~ 200kW | 0.45 ~ 200kW | 0.9 ~ 25kW | 0.25 ~ 60kW | 0.75 ~ 25kW | 0.4 ~ 15kW | 0.3 ~ 80kW | 0.2 ~ 80kW | 0.45 ~ 80kW | ||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Recirculating Heater Chillers
Temperature Control Range: -45°C to +250°C
Temperature range | -25°C ~ +200°C series | -45°C ~ +250°C series | |||||||
Cooling Capacity | 1 ~ 15kW | 0.25 ~ 15kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |