Low Temperature Refrigeration Chiller for Hydrogen Production and Hydrogen Refueling Station
There are more and more hydrogen production stations, and its safety is also concerned by the industry, and chiller equipment can provide refrigeration and low temperature for hydrogen production stations, so what aspects should be paid attention to when choosing a chiller?
Let me explain to you:
The hydrogen production scale of the hydrogen production station;
The climatic conditions of the location of the hydrogen production station;
Requirements for the use of hydrogen production stations.
The specific calculation process of chiller selection is as follows:
1. Determine the scale of hydrogen production
First of all, it is necessary to determine the hydrogen production scale of the hydrogen production station, that is, how much hydrogen needs to be produced every day. This data is usually determined according to usage scenarios and user needs, such as fuel cell vehicles, industrial uses, etc. According to the scale of hydrogen production, the cooling capacity demand of the chiller can be calculated.
2. Consider climate conditions
The climatic conditions where the hydrogen production station is located are also one of the factors that need to be considered when choosing a chiller. Depending on the climatic conditions, the amount of cooling required during the high temperature period in summer will also vary. For example, more powerful cooling capacity is required in hot regions to ensure the steady production of hydrogen.
3. Determine usage requirements
The use requirements of the hydrogen production station also have an impact on the selection of chillers. Different hydrogen production stations may require different types of cooling equipment, such as air-cooled or water-cooled cooling equipment.
In addition, some other requirements need to be considered, such as system reliability, energy consumption, maintenance costs, etc., which will have an impact on the final chiller selection.
Based on the above factors, the best chiller suitable for the hydrogen production station can be determined. When selecting a specific model, it is also necessary to consider various performance indicators of the chiller, such as efficiency, energy consumption, life, stability, noise and other factors.
Our chillers can provide customers with the selection of chillers for hydrogen production stations, and provide you with precisely matched chillers. Chillers are widely used in hydrogen refueling stations, energy storage, photovoltaic power generation, wind turbines, new energy battery manufacturing and other fields.
Customized Solutions For Your Business
Low Temperature Chillers (Custom Designs)
We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.
Temperature range | -25°C ~ -5°C series | -45°C ~ -10°C series | -60°C ~ -10°C series | -80°C ~ -30°C series | -110°C ~ -50°C series | -150°C ~ -110°C series |
Cooling Capacity | up to 360kW | up to 360kW | up to 360kW | up to 270kW | up to 180kW | up to 11kW |
Recirculating Chillers (Custom Designs)
Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.
Temperature range | -25°C ~ +30°C series | -45°C ~ +30°C series | -60°C ~ -20°C series | -80°C ~ -20°C series | -120°C ~ -70°C series |
Cooling Capacity | up to 38kW | up to 12kW | up to 7.2kW | up to 7.2kW | up to 8.6kW |
Room Temperature Chillers / Small Chillers (Custom Designs)
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C series |
Cooling Capacity | up to 0.9kW | up to 50kW |
Direct Cooling Type Refrigeration Equipments (Custom Designs)
It is suitable for places with small heat exchange area and large heat exchange.
Temperature range | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
Compressor Power | up to 8HP | up to 8HP*2 | up to 45HP*3 |
Chillers for Automotive Battery Test (Custom Designs)
Temperature simulation for vehicle quality test: battery life test, fuel injector/motor test bench, airbag test, component test bench, etc.
Temperature range | -25°C ~ +100°C | -40°C ~ +100°C | 0°C ~ +100°C | -40°C ~ +135°C |
Cooling Capacity | up to 38kW | up to 60kW | up to 60kW | up to 60kW |
Temperature / Pressure / Flow can be independently controlled.
1&2: one machine for two groups control.
Temperature range | -40 ~ +100℃ 1&2 | 0 ~ +100℃ 1&2 |
Cooling Capacity | up to 60kW*2 | up to 60kW*2 |
Temperature remains constant, pressure / flow can be independently controlled.
1&3: one machine for three groups control.
1&6: one machine for six groups control.
Temperature range | -40 ~ +100℃ 1&2 | -40 ~ +100℃ 1&3 | -40 ~ +100℃ 1&6 | -20 ~ +100℃ 1&6 | 0 ~ +100℃ 1&2 | 0 ~ +100℃ 1&3 | 0 ~ +100℃ 1&6 |
Cooling Capacity | up to 60kW | up to 60kW | up to 60kW | up to 60kW | up to 60kW | up to 60kW | up to 60kW |
Semiconductor Chillers (TES series) (Custom Designs)
Suitable for precise temperature control of electronic components. In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing and other environmental testing simulations.
Temperature range | -45°C ~ +250°C series | -85°C ~ +200°C series | -60°C ~ +200°C series |
Cooling Capacity | up to 25kW | up to 25kW | up to 60kW |
Semiconductor Chillers (LTS series) (Custom Designs)
Suitable for precise temperature control of electronic components. In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing and other environmental testing simulations.
Temperature range | -20°C ~ +80°C series | -45°C ~ +80°C series | -60°C ~ +80°C series | -80°C ~ +80°C series |
Flow Control | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min |
Chillers for Energy Storage(Custom Designs)
Liquid Cooling Solutions For Battery Energy Storage Systems
Temperature range | -45°C ~ +55°C |
Cooling Capacity | up to 45kW |
Screw Chillers (Custom Designs)
Low temperature screw chillers and room temperature screw chillers
Temperature range | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Cooling Capacity | up to 1027kW (Single Compressor) | up to 2134kW (Dual Compressor) | up to 934kW (Single Compressor) | up to 1940kW (Dual Compressor) | up to 467kW (Single Compressor) | up to 497kW (Single Compressor) |