Low Temperature Refrigeration Liquid Circulation Pump System

ClassificationIndustry News 80 0

Low Temperature Refrigeration Liquid Circulation Pump System

 

The cryogenic refrigeration liquid circulation pump system is a key component in laboratory and industrial cooling applications. It pumps cryogenic coolant through the system to remove heat and maintain a constant low temperature environment.

Main features and advantages of cryogenic refrigeration liquid circulation pump system

1. Efficient heat exchange: The high-efficiency heat exchanger design ensures fast and effective heat transfer to keep the target equipment or medium at the required low temperature.

2. Strong stability: Provides continuous and stable cooling capacity, suitable for long-term uninterrupted operation, and meets the strict requirements of precision experiments and production processes.

3. High flexibility: Pumps with different flow rates and heads and systems with different cooling capacities can be selected according to specific application requirements. Some systems also support multiple outputs to adapt to diverse cooling needs.

4. Easy operation: Most systems are equipped with intuitive operation panels and controllers, supporting temperature presets, automatic adjustment and fault alarms, which are convenient for users to monitor and manage.

5. Safe and reliable: Built-in safety protection measures, such as pressure protection and overload protection, prevent damage caused by system abnormalities and ensure safe operation.

6. Easy maintenance: Durable materials and modular design facilitate daily inspection and maintenance, reducing downtime.

 

Low Temperature Refrigeration Liquid Circulation Pump System

 

Application industries of cryogenic refrigeration liquid circulation pump system

Biomedicine: Maintain low temperature conditions and protect sample activity in biological sample storage, DNA sequencing, protein crystallization and other research.

Chemical and pharmaceutical: Control reaction temperature in chemical synthesis and drug preparation to improve product quality and yield.

Laser and optoelectronics: Provide cooling for high-precision optical equipment such as lasers and optoelectronic sensors to ensure stable performance.

Material science: Create and maintain low temperature test environment in material processing and performance testing (such as thermal expansion coefficient measurement).

If you are considering purchasing a cryogenic refrigeration liquid circulation pump system for your laboratory or project and need selection advice, brand recommendation or specific technical parameter comparison, please explain your specific needs in detail and I will provide you with further guidance and support.

 


 

We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.

We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.

request

Email: lilia@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 

scan

 

 


low temperature chiller

1.Low Temperature/Cryogenic Chillers

(Custom Designs)

  • Temperature range: -150℃ ~ -5℃
  • International brand compressor, high cooling efficiency
  • Secondary subcooling technology, fast cooling speed

Six product series

ModelLC seriesLJ seriesLN seriesLD seriesCDLJ seriesSLJ series
Temperature range -25 ~ -5 °C -45 ~ -10 °C -60 ~ -10 °C -80 ~ -30 °C-110 ~ -50 °C -150 ~ -110 °C
Cooling capacity12 … 360 kW6 … 180 kW6 … 180 kW4 … 180 kW2 … 120 kW2.5 … 11 kW
Temperature stability±0.5 ℃±0.5 ℃±0.5 ℃±0.5 ℃±0.5 ℃±0.5 ℃
Pump flow pressure6.6 … 25 m³/h6.6 … 25 m³/h6.6 … 25 m³/h6.6 … 25 m³/h6.6 … 25 m³/h6.6 … 25 m³/h
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


recirculating chiller

2.Recirculating Chiller/Refrigerated Circulator

(Custom Designs)

  • Temperature range: -120℃ ~ +30℃
  • International brand compressor, cascade refrigeration technology
  • Use ethylene glycol or a mixture of ethylene glycol and water

Five product series

ModelLX seriesLT-45 seriesLT-60 seriesLT-80 seriesLT-120 series
Temperature range -25 ~ +30 °C -45 ~ +30 °C -60 ~ -20 °C -80 ~ -20 °C -120 ~ -70 °C
Cooling capacity0.8 … 30 kW0.75 … 12 kW0.4 … 6 kW0.2k … 6 kW0.3 … 5 kW
Temperature stability±0.5 ℃±0.5 ℃±0.5 ℃±0.5 ℃±0.5 ℃
Pump flow pressure20 … 250 L/min20 … 50 L/min20 … 50 L/min20 … 50 L/min20 … 35 L/min
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


 

Precision Chillers / Small Chillers3.Small Chillers / Mini Chillers

(Custom Designs)

  • Temperature range: -18℃ ~ +35℃
  • International brand compressor, stable performance
  • Energy saving, high temperature control accuracy

Two product series

ModelFL-800FL series
Temperature range -18 ~ +30 °C +5 ~ +35 °C
Cooling capacity0.35 ~ 0.9 kW1.8 … 50 kW
Temperature stability±0.5 ℃±0.5 ℃
Pump flow pressure25 … 250 L/min10 L/min
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


4.Cooling and Heating Chillers

(Custom Designs)

  • Temperature range: -120℃ ~ +350℃
  • High-precision, intelligent temperature control
  • Fully closed system to extend the service life of thermal fluid

Eleven product series

ModelSUNDI-1 seriesSUNDI-2 seriesSUNDI-23 seriesSUNDI-4 seriesSUNDI-43 seriesSUNDI-6 seriesSUNDI-63 seriesSUNDI-7 seriesSUNDI-8 seriesSUNDI-9 seriesSUNDI-10 series
Temperature range -10 ~ +150 °C-25 ~ +200 °C -25 ~ +300 °C-45 ~ +250 °C -45 ~ +300 °C -60 ~ +250 °C -60 ~ +300 °C -70 ~ +250 °C -80 ~ +250 °C-90 ~ +250 °C -100 ~ +100 °C
Cooling capacity1.5 … 15 kW1 … 200 kW1 … 200 kW0.45 … 200 kW0.9 … 25 kW0.25 … 60 kW0.75 … 25 kW0.4 … 15 kW0.3 … 80 kW0.2 … 80 kW0.45 … 80 kW
Temperature stability±0.5 ℃±0.5 ℃±0.5 ℃±0.5 ℃±0.5 ℃±0.5 ℃±0.5 ℃±0.5 ℃±0.5 ℃±0.5 ℃±0.5 ℃
Pump flow pressure20 … 75 L/min20 … 600 L/min20 … 600 L/min20 … 600 L/min35 … 150 L/min20 … 250 L/min35 … 150 L/min20 … 110 L/min20 … 400 L/min20 … 400 L/min35 … 400 L/min
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


SEMICONDUCTOR CHILLER

 

5.High Temperature Chillers

(Custom Designs)

  • Temperature range: -100℃ ~ +80℃
  • International brand compressors and other accessories
  • Fully sealed design to ensure the purity of the medium

Five product series

Model FLT seriesFLT-2 seriesFLT-4 seriesFLT-8 seriesFLT-10 series
Temperature range +5 ~ +40 °C -25 ~ +40 °C -45 ~ +40 °C -80 ~ +80 °C -100 ~ +80 °C
Cooling capacity6 … 40 kW2 … 15 kW1 … 8 kW0.6 … 3 kW1.5 … 3 kW
Temperature stability±0.1 ℃±0.1 ℃±0.1 ℃±0.1 ℃±0.1 ℃
Pump flow pressure10 … 75 L/min10 … 75 L/min10 … 75 L/min7 … 45 L/min7 … 45 L/min
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Latest News
Request a Quote
Name
Email Address
Phone
Company
Message

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller