Process Glycol Chillers
Contact us today for the perfect temperature control solution
Process glycol chillers are devices that can cool water or other liquids under constant temperature conditions. It mainly consists of refrigeration unit, condenser, evaporator, control system, etc. In actual work, process glycol chillers have been widely used in food processing, medicine, chemical industry, semiconductor and other fields.
Chillers are composed of compressors, evaporators, condensers, throttling components, and electronic control systems. However, process glycol chillers use low-temperature compressors and are equipped with separators and other components, which are different from ordinary chillers. difference.
How does process glycol chiller work?
1. Compression
In order to keep the pressure in the evaporator low enough to ensure that the refrigerant is boiling at a low enough temperature, a compressor is used to pump away the evaporated refrigerant gas, that is, to compress the low-temperature and low-pressure refrigerant vapor into high-temperature and high-pressure gas. Refrigerant gas. When the suction speed of the compressor is greater than the evaporation speed of the refrigerant, the evaporation pressure will decrease and the evaporation temperature will also decrease; conversely, if the suction speed of the compressor is less than the refrigerant’s evaporation speed, the evaporation temperature and pressure will rise accordingly. high.
2. Condensation
The high-temperature and high-pressure refrigerant is condensed into liquid in the condenser. In the condenser, the refrigerant releases heat to air or water that is lower than its temperature. This part of the heat includes the heat absorbed by the refrigerant when it evaporates in the evaporator and the heat converted into it when the compressor compresses it. Special note: the temperature of the air or water must be lower than the temperature of the refrigerant, otherwise the refrigerant cannot release heat, that is, the temperature of the cooling medium (cooling tower water or air) is lower than the temperature of the refrigerant gas at the compressor outlet.
3. Throttling
Through the throttle, the pressure of the refrigerant is reduced from the condensing pressure to the evaporating pressure. The liquid coming out of the condenser is stored in the liquid receiver. At this time, the refrigerant is at normal temperature and high pressure. After passing through the expansion valve, the boiling point is lowered due to the pressure drop. After the liquid enters the evaporator, it easily absorbs heat and evaporates.
4. Evaporation
The low-temperature and low-pressure refrigerant liquid that passes through the throttle exchanges with the secondary refrigerant in the evaporator, absorbs heat, and becomes saturated or superheated vapor to be compressed by the compressor.
We provide complete temperature control systems design and manufacturing. From standard models to complete customized products up to 900 tons. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.
We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.
Email: info@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
Recirculating Chillers / Refrigerated Circulator
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -25°C ~ +30°C series | -45°C ~ +30°C series | -60°C ~ -20°C series | -80°C ~ -20°C series | -120°C ~ -70°C series | ||||
Cooling Capacity | 0.8 ~ 30kW | 0.75 ~ 12kW | 0.4 ~ 6kW | 0.2 ~ 6kW | 0.3 ~ 5kW | ||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Water Chillers / Small Chillers
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C series | |||||||
Cooling Capacity | 0.35 ~ 0.9kW | 1.8 ~ 50kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Low Temperature Chillers
We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.
Temperature range | -25°C ~ -5°C series | -45°C ~ -10°C series | -60°C ~ -10°C series | -80°C ~ -30°C series | -110°C ~ -50°C series | -150°C ~ -110°C series | |||
Cooling Capacity | 12 ~ 360kW | 6 ~ 180kW | 6 ~ 180kW | 4 ~ 180kW | 2 ~ 120kW | 2.5 ~ 11kW | |||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Cooling and Heating Chillers
Temperature Control Range: -120°C to +350°C
cooling and heating thermostat, widely used in various industry.
Temperature range | -10 ~ +150°C series | -25 ~ +200°C series | -25 ~ +300°C series | -45 ~ +250°C series | -45 ~ +300°C series | -60 ~ +250°C series | -60 ~ +300°C series | -70 ~ +250°C series | -80 ~ +250°C series | -90 ~ +250°C series | -100 ~ +100°C series | ||
Cooling Capacity | 1.5 ~ 15kW | 1 ~ 200kW | 1 ~ 200kW | 0.45 ~ 200kW | 0.9 ~ 25kW | 0.25 ~ 60kW | 0.75 ~ 25kW | 0.4 ~ 15kW | 0.3 ~ 80kW | 0.2 ~ 80kW | 0.45 ~ 80kW | ||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Recirculating Heater Chillers
Temperature Control Range: -45°C to +250°C
Temperature range | -25°C ~ +200°C series | -45°C ~ +250°C series | |||||||
Cooling Capacity | 1 ~ 15kW | 0.25 ~ 15kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |