Search Search all

SUNDI-2A10W-2T N / SUNDI-2A10-2T N Heating Cooling Integrated Machine

Recently, some parts have a long construction period, please place an order as soon as possible for urgent orders

Product parameter

  • Power:31kW
  • Heating power:10*2kW
  • Flow:50*2L/min
  • Pressure:2bar
  • Temperature control accuracy:±0.5℃

All products support customized services

 

Request a Quote       Email Us        More Product Models

Typical Application Of Dynamic Temperature Control System:

Dynamic thermostatic control of cold and heat source of high pressure reaction kettle, dynamic thermostatic control of double layer glass reaction kettle, and dynamic thermostatic control of cold and hot source of double-layer reactor. Micro-channel reactor thermostatic control, small temperature control system, steam – feeding system temperature control, material low temperature aging test. The thermostatic control of the combined chemical cold source heat source, the cooling heating of the semiconductor equipment and the heating temperature of the vacuum chamber are controlled.

Structure and principle of Dynamic Temperature Control System: 

Ultra high temperature cooling technology can directly cool from a high temperature of 300℃(because only the heat transfer medium in the expansion chamber contacts with oxygen in the air (and the temperature of the expansion tank is between normal temperature and 60℃), which can reduce the risk of heat transfer medium being oxidized and absorbing water in the air. At high temperature, no heat conducting medium evaporates, and continuous temperature control of – 80℃ ~ 190℃, – 70℃ ~ 220℃, – 88℃ ~ 170℃, – 55℃ ~ 250℃ and – 30℃ ~ 300℃ can be realized without pressurization.

Advantages of Equipment Functions and Accessories

When the temperature is high, there is no evaporation of heat conducting medium, and the continuous temperature control of -90~195℃,-70~220℃,-55~250℃ and -25~300℃ can be realized without pressure. Adopt the design of fully closed pipeline, reduce the demand of heat-transfer fluid, improve the heat utilization rate of the system, and achieve rapid temperature rise and fall. The heat conducting medium in the expansion vessel does not participate in the circulation, which can reduce the risk of moisture absorption and volatilization during the operation of the heat conducting medium.

Product parameters(All products can be customized

ModelSUNDI-225W-2T N
SUNDI-225-2T N
SUNDI-235W-2T N
SUNDI-235-2T N
SUNDI-255W-2T N
SUNDI-255-2T N
SUNDI-275W-2T N
SUNDI-275-2T N
SUNDI-2A10W-2T N
SUNDI-2A10-2T N
Temp. range-25℃~+200℃
Control ModeFeedback PID + Our special dynamic control calculation, PLC controller
Temp. controlprocess temp. control and jacket temp. control model   TWO  GROUPS
Temp. differenceSet or control the temperature difference between jacket oil and raw material process  TWO  GROUPS
Communication PortocolMODBUS RTU Protocol,RS485 interface
Material temp. feedbackPT100 OR 4~20mA or communication(normal: PT100)
Temp. feedbackthe temp. of three points: the inlet and outlet of equipment,  reactor material temp.(external temp. sensor)*2
Medium temp. acccuracy±0.5℃
Material temp. accuracy±1℃
Heating power kW2.5*23.5*25.5*27.5*210*2
Cooling capacity kW at  ℃200℃2.5*23.5*25.5*27*210*2
100℃2.5*23.5*25.5*27*210*2
20℃2.5*23.5*25.5*27*210*2
0℃1.5*22.5*23.5*25*27.5*2
-20℃1*21.6*22.1*23*24*2
Circulation pump max
L/min bar
20*235*235*250*250*2
1.52222
CompressorTecumseh closed compressorEmerson copeland vortex flexible
Expansion valveEmerson thermal expansion valve/danfoss thermal expansion valve.
EvaporatorDANFOSS/KAORI Plate heat exchanger
Operation Panel7-inch touch screen,show temp curve\EXCEL data output
Safety protectionSelf-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation systemThe whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
RefrigerantR404A/R507C, optional: R448A
Connection sizeG3/4G3/4G3/4G3/4G1
Water-cooled type W(cooling water@20℃)1200L/H
1.5bar~4bar
1400L/H
1.5bar~4bar
1700L/H
1.5bar~4bar
2100L/H
1.5bar~4bar
2500L/H
1.5bar~4bar
Dimension(water type)cm55*100*17570*100*17570*100*17580*120*185100*150*185
Dimension(air type)cm55*100*17555*100*17570*100*17570*100*17580*120*185
Weight kg240285345385480
Power 380V 50HZ220V  7.5kW11.5kW17kW23kW31kW

 


 

Customized Solution For Your Needs

 


 

We are a designer and manufacturer of temperature control equipment. We have designed OEM products for aerospace, automotive, defense, energy, chemical, industrial, medical, and semiconductor application, all delivered with capabilities specific to the demanding needs of our customers.

for-Ultrasonic-instrumentsfor-semiconductorfor-Rotary-Evaporatorfor reactor
for-multi-reactorsfor-Metal-Finishingfor-materialfor-big-reactorfor-Integrated-circuits-testfor-Industrial-Manufacturing
for-industrial-processfor-IC-testfor-Hydraulic-Pressfor-Heat-Treatingfor-glass-reactorfor-gas-recovery
for-Extractionfor-electronicfor-Distillationfor-chip-testfor-chemicalfor-biotechnology
for-batteryfor-automotivefor-Aerospacefor-laboratoryfor-reactorsfor-industry

 

 

Custom Options

  • Custom Sizes

Whether it is portable, compact, large and small chillers, we can custom design them according to your requirements.

No matter how many tons of product you need, we can create the best solution.

  • Custom Temperature Ranges

We can create a custom solution for temperatures from -150℃ to +350℃.

Custom temperature ranges for specific industries.

  • Custom Cooling / Heating Capacity

We offer a very wide range of cooling / heating capacities for various industries.

  • Custom Refrigeration / Heating Types

We provide products of various refrigeration / heating types, including but not limited to air-cooled, water-cooled and evaporative-condensing chillers.

Regardless of the type of refrigeration compressor, we can design it according to your requirements.

  • Custom Accessories

We use a variety of internationally renowned accessories, all of which can be customized for your needs, such as compressors, evaporators, heat exchangers, circulation pumps, controllers, expansion valves and shell materials, etc.

  • Custom Voltage

Customize voltage and phase according to your needs.

Optional 110V/60HZ, 220V/60HZ, 380V/50HZ, 220V/50HZ, 400V/50HZ, 460V/60HZ, 440V~480V/60HZ, etc.

  • Other Options

 

 

 

Our Advantages

We specializes in custom temperature control systems. We have our liquid chiller system designs in everything from Semiconductor process equipment, FCEV Hydrogen Refeuling Stations and Bio-Pharmaceutical OEM process control systems. LNEYA can design any shape to fit around your equipment, pump selections to meet all your needs, air-cooled, water-cooled, multiple cooling loops. Special interface requirements, digital or analog, pump output heat transfer fluid flow and pressure control, temperature cycling and ramping all available.

Please contact us if you require a temperature control system specifically tailored to your needs. We will be happy to advise you individually and find the right solution for you. It is also possible to show you reference projects that have similar requirements and have already been realized.

 

Contact Us For Custom Solutions

Contact Us for further assistance with all standard and custom chiller needs

 

 

Please fill out the form below and one of our team members will be in touch shortly!

Email: lilia@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

scan

After sale service

Quality assurance

Guarantee that the goods are sold to be conform to the provisions of the contract and qualified new products by factory inspection, quality performance, technical indicators and configured are in accordance with manufactures and technical documents stipulated in the contract.

Installation and debugging

After the arrival of the goods, my company or my company agent is responsible for installation and debugging of equipment need on-site installation and debugging.

Inspection and acceptance

After installation and debugging, acceptance by the customer to confirm the goods to be conform to the provisions of the contract and qualified new products, quality performance, technical indicators and configured are in accordance with manufactures and technical documents stipulated in the contract, and after the confirmation of a full set of technical documents, sign the installation acceptance report and confirm acceptance.

Training

At the same time of installation and debugging of equipment, my company’s after-sales service engineer is responsible for technical training for user until user can be skilled of operation. In the process of using equipment by customer, customer can consult relevant technical issues to after-sales service personal of our company at any time, according to the situation, my company will arrange training on site or remote.

After sale service commitment

A full free one year warranty since the date of acceptance, during the warranty period, all repairs and spare parts are free of charge(instrukent malfunction caused bu human factors will be charged of cost price of spare parts); After the warranty period, we will be responsible for maintenance of equipment for lifetime, according to the actual maintenance fees, appropriate fee will be charged.

(PS:There will have extra charge if the customer need on-site service. And customers need to describe the issue first and then send some failed pics or videos in advance, then Lneya judge if it is possible to go for after-Sales on site. )

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller