ZLF-35N / ZLF-35NS / ZLF-35NH / ZLF-35NSH
Product parameter
- Power:2.3kW or 27.3kW(with H)
- Heating power:25kW(with H)
- Flow:150L/min
- Pressure:2.5bar
- Temperature control accuracy:±1℃
All products support customized services
Phone: +86-18806176058
Search Search all
All products support customized services
Detailed Description
Excellent performance, high precision, intelligent temperature control, very wide temperature control range, from -120 °C ~ 350 °C, suitable for most enterprises temperature control needs. Product temperature control accuracy of ± 0.5 ° C, cooling power from 0.5 kW to 1200 kW can provide the corresponding products.
Temperature Process Control Principle (Control Reaction Kettle Material Temperature)
Model | ZLF-35N ZLF-35NS ZLF-35NH ZLF-35NSH | ||||
Temp. range ℃ | -45~ 250degree (setting the max temp according to the supplier heating or cooling source) -40~135degree(The maximum temperature range can be operated by using glycol water formula.) | ||||
ZLF- N | The main cold source/or main heat source is used to regulate the flow of the system through proportional regulation system, and control the heat of the clamping of the reaction tank, and a set of heat exchanger for heating or cooling is controlled or cooled. | ||||
ZLF- NS | Besides ZLF- N function,add one set heater used to reduce high temp. | ||||
ZLF- NH | Besides ZLF- N function,add electrical heating function | ||||
ZLF- NSH | Besides ZLF- N function,add one set heater used to reduce high temp and electrical heating function | ||||
Heat exchanger area | 3.5m2 | ||||
Electric heating function H | 25KW | ||||
With “H” has heating function | |||||
Control mode | Feed forward PID + Our special dynamic control calculation,LNEYA PLC controller | ||||
Communication protocol | MODBUS RTU protocol,RS485 interface,optional Ethernet interface/R232 interface | ||||
Temp control selection | Process temp control | ||||
Temperature feedback | The temperature of three points: the inlet and outlet of heat-conducting medium, material in reactor(External temperature sensor), PT100 sensor | ||||
Process temp. feedback | Raw material process feedback:PT100 or 4~20mA or communication given Temp. feedback:PT100 | ||||
temp feedback: normal PT100 | |||||
Temperature accuracy | ±1℃ | ||||
Circulation pump | 150L/min 2.5BAR | ||||
Input and display | 7-inch color touch screen,temperature graph display | ||||
Safety protection | Self-diagnosis function;freezer overload protection;high pressure switch;overload relay;thermal protection device;liquid low level protection;high temp. Protection and temp. fault protection. | ||||
Perform valve piece | Electric proportional control valve, control signal 4~20mA. | ||||
Piping material | SUS304 | ||||
Connection size | DN40 | ||||
Dimension mm | 1000*950*1750 | ||||
Dimension EX mm | 1000*1200*1750 | ||||
Power AC380V50HZ | 1.6kw(max) | ||||
With H power AC380V 50HZ | 26.6kw(max) | ||||
Case material | SUS 304 |
LNEYA attends various exhibitions at home and abroad every year. At the exhibition, we show the latest research equipment of LNEYA. Every year, long-term cooperative customers will come to exhibitions and communicate with us. We are also actively developing new customers to provide them with high quality machines and services.
Guarantee that the goods are sold to be conform to the provisions of the contract and qualified new products by factory inspection, quality performance, technical indicators and configured are in accordance with manufactures and technical documents stipulated in the contract.
After the arrival of the goods, my company or my company agent is responsible for installation and debugging of equipment need on-site installation and debugging.
After installation and debugging, acceptance by the customer to confirm the goods to be conform to the provisions of the contract and qualified new products, quality performance, technical indicators and configured are in accordance with manufactures and technical documents stipulated in the contract, and after the confirmation of a full set of technical documents, sign the installation acceptance report and confirm acceptance.
At the same time of installation and debugging of equipment, my company’s after-sales service engineer is responsible for technical training for user until user can be skilled of operation. In the process of using equipment by customer, customer can consult relevant technical issues to after-sales service personal of our company at any time, according to the situation, my company will arrange training on site or remote.
A full free one year warranty since the date of acceptance, during the warranty period, all repairs and spare parts are free of charge(instrukent malfunction caused bu human factors will be charged of cost price of spare parts); After the warranty period, we will be responsible for maintenance of equipment for lifetime, according to the actual maintenance fees, appropriate fee will be charged.
(PS:There will have extra charge if the customer need on-site service. And customers need to describe the issue first and then send some failed pics or videos in advance, then Lneya judge if it is possible to go for after-Sales on site. )