UST-A2530 / UST-A2530W Laboratory and Industrial Heater
Product parameter
- Power: 28kW
- Heating power:25kW
- Flow:150L/min
- Pressure:2.5bar
- Temperature control accuracy:±0.5℃
Phone: +86-18806176058
Search Search all
Detailed Description
LNEYA specializes in the production of R&D heating systems with a temperature control range of 50 to 300 degrees, which enables high temperature cooling processes, from 40 degrees directly to 50 degrees. Equipped with a heating and cooling integrated container, the heat exchange area is large, the temperature rise and fall is fast, and the heat transfer oil demand is small.
1. UST-series with the function of cooling down from high temperature and the temperature range from 250℃ to 50℃.
2. Equipped with heating and cooling system, large heat exchange area, rapid speed of heating-cooling, the small demand for heat conducting medium.
3. Can heating and cooling continuously.
4. The whole system is closed, there is no oil mist at high temperature, no volatilization of heat conducting medium at high temperature.
5. With inter temperature sensor PT-100 to adjust internal circulation temperature.
6. The whole system is a closed liquid circulation system with expansion tank, the expansion tank, and liquid circulation are thermal insulation, do not participate in liquid circulation, regardless of high or low temperature, the medium in the expansion tank is limited to 60℃.
7. Allow fill in 15℃ cooling water, to enlarge temperature range of 25℃ to 250℃.
Heating temperature control system consistent with SUNDI-series, but with only heating function, cooling can flow in water to cool to room temperature.
Widely used in petrochemical, chemical, pharmaceutical, bio-engineering, life science, Light industry and food,Industry, sample testing and so on.
Model | UST-A2530 / UST-A2530W | ||||
Temp. range | +50℃~+300℃ | ||||
Control Mode | Feedback PID + Our special dynamic control calculation, PLC controller | ||||
Temp. control | Process temp. control and jacket temp. control model | ||||
Temp. difference | Set or control the temperature difference between jacket oil and raw material process | ||||
Program Editor | 10 programs, each program can edit 42 steps. | ||||
Communication Portocol | MODBUS RTU Protocol,RS485 interface | ||||
Material temp. feedback | PT100 OR 4~20mA or communication(normal: PT100) | ||||
Temp. feedback | The temp. of three points: the inlet and outlet of equipment, reactor material temp.(external temp. sensor) | ||||
Medium temp. acccuracy | ±0.5℃ | ||||
Material temp. accuracy | ±1℃ | ||||
Heating power kW | 25 | ||||
Cooling capacity kW at ℃ | 300 ℃ | 25 | |||
200 ℃ | 25 | ||||
100 ℃ | 20 | ||||
65 ℃ | 8.5 | ||||
Circulation pump max L/min bar | 150 | ||||
2.5 | |||||
Connection size | DN32 PN10 | ||||
Dimension cm | 70*100*175 | ||||
Weight kg | 265 | ||||
Power 380V 50HZ | 28kw |
LNEYA attends various exhibitions at home and abroad every year. At the exhibition, we show the latest research equipment of LNEYA. Every year, long-term cooperative customers will come to exhibitions and communicate with us. We are also actively developing new customers to provide them with high quality machines and services.
Guarantee that the goods are sold to be conform to the provisions of the contract and qualified new products by factory inspection, quality performance, technical indicators and configured are in accordance with manufactures and technical documents stipulated in the contract.
After the arrival of the goods, my company or my company agent is responsible for installation and debugging of equipment need on-site installation and debugging.
After installation and debugging, acceptance by the customer to confirm the goods to be conform to the provisions of the contract and qualified new products, quality performance, technical indicators and configured are in accordance with manufactures and technical documents stipulated in the contract, and after the confirmation of a full set of technical documents, sign the installation acceptance report and confirm acceptance.
At the same time of installation and debugging of equipment, my company’s after-sales service engineer is responsible for technical training for user until user can be skilled of operation. In the process of using equipment by customer, customer can consult relevant technical issues to after-sales service personal of our company at any time, according to the situation, my company will arrange training on site or remote.
A full free one year warranty since the date of acceptance, during the warranty period, all repairs and spare parts are free of charge(instrukent malfunction caused bu human factors will be charged of cost price of spare parts); After the warranty period, we will be responsible for maintenance of equipment for lifetime, according to the actual maintenance fees, appropriate fee will be charged.
(PS:There will have extra charge if the customer need on-site service. And customers need to describe the issue first and then send some failed pics or videos in advance, then Lneya judge if it is possible to go for after-Sales on site. )