Circulating Cooling System
Contacte-nos hoje para obter a solução perfeita de controlo da temperatura
The four major components of the circulating cooling system: compressor, condenser, throttling mechanism, and evaporator.
The functions of the four major components of the circulating cooling system
Compressor-adiabatic compression function: compresses medium-low temperature and low-pressure refrigerant into high-temperature and high-pressure superheated steam.
Condensador – Condensation (heat release): The high-temperature and high-pressure gaseous refrigerant dissipates heat through heat exchange, and the refrigerant becomes a medium-high-temperature and high-pressure liquid.
The throttling mechanism has a throttling effect: through the throttling effect, the medium-high temperature and high-pressure liquid refrigerant is turned into a low-temperature and low-pressure gas-liquid two-phase refrigerant.
Evaporador-evaporation effect (heat absorption): The refrigerant absorbs heat when flowing through the evaporator, and turns the refrigerant into a medium-low-temperature and low-pressure gaseous refrigerant through the action of the heat exchanger.
The role of other components of the circulating cooling system
High and low pressure controller: The high and low pressure protector of the refrigeration system. When the high pressure is too high or the low pressure is too low, an alarm signal is generated.
Oil separator: Separates the refrigerant and refrigeration oil in the exhaust pipe. The refrigerant continues to enter the condenser along the pipeline, and the separated refrigeration oil returns to the compressor through the oil return pipe.
Condensing pressure regulating valve: It plays the role of regulating the condensing pressure. It can prevent the condensing pressure from being too high and causing high-pressure protection. It can also prevent the condensing pressure from being too low and causing insufficient pressure difference between the front and rear of the throttling structure. Of course, not every system needs this valve.
Reservoir: Stores excess refrigerant in the refrigeration system.
Under low-temperature conditions, the refrigerant circulating in the refrigeration system will be much lower than the refrigerant under normal temperature conditions. If there is no liquid reservoir at this time, the excess refrigerant will be stored in the condenser, accounting for most of the replacement time. thermal area.
Ball valve: A manually opened and closed valve that can cut off the refrigerant circuit.
01) It can be used to close the refrigerant in the condenser or liquid receiver when replacing the filter or thermal expansion valve, so that there is no need to drain the refrigerant of the entire system.
02) Add refrigerant to the system: When debugging a new machine, all the refrigerant cannot be added in the shutdown state. At this time, you need to turn on the compressor and suck the refrigerant into the system through the suction pipe of the compressor. However, many normal temperature During working conditions, the pressure of the evaporator is actually not low or even higher than the pressure of the refrigerant tank, and the refrigerant cannot be added either. Then at this time we can close the ball valve and switch the refrigerant coming from the condensing side, and the compressor can suck the refrigerant into the system.
03) Recycle refrigerant
Drying filter: As the name suggests, it plays the role of removing moisture and filtering impurities in the refrigeration system. This filter is placed in front of the expansion valve to prevent impurities from entering the valve core and blocking the expansion valve.
Solenoid valve: An electric component that can cut off the refrigeration pipeline manually or automatically; it also plays a great role in the refrigeration system.
Evaporation pressure regulating valve: mainly prevents the evaporation pressure from being too high, causing compressor failure.
Crankcase pressure regulating valve: It can also be called suction pressure regulating valve to prevent excessive suction pressure from causing excessive load on the compressor and damaging the compressor.
The evaporation pressure regulating valve and crankcase pressure regulating valve are not required by everyone’s system. Generally, in small systems, we can use a thermal expansion valve with MOP function instead.
Suction filter: Installed on the suction pipe to filter impurities in the refrigeration system to prevent them from entering the compressor and causing compressor failure.
Fornecemos a conceção e o fabrico de sistemas completos de controlo de temperatura. Desde modelos standard a produtos personalizados completos até 900 . Somos especializados no serviço ao cliente e dedicamo-nos a ajudar cada cliente a ter o sistema de controlo de temperatura ideal para as suas necessidades específicas.
Fornecemos soluções personalizadas não padronizadas. Estão disponíveis chillers de refrigeração simples e unidades combinadas de refrigeração e aquecimento.
Correio eletrónico: info@lneya.com ID WeChat: +8615251628237 WhatsApp: +86 17851209193
Chillers de recirculação / Circulador refrigerado
O refrigerador pode ser amplamente utilizado em várias indústrias e laboratórios, e suporta um design personalizado.
Faixa de temperatura | Série -25°C ~ +30°C | Série -45°C ~ +30°C | Série -60°C ~ -20°C | Série -80°C ~ -20°C | Série -120°C ~ -70°C | ||||
Capacidade de arrefecimento | 0,8 ~ 30kW | 0,75 ~ 12kW | 0,4 ~ 6kW | 0,2 ~ 6kW | 0,3 ~ 5kW | ||||
Nota: Qualquer faixa de temperatura de -150 ℃ ~ +350 ℃ e qualquer capacidade de resfriamento pode ser personalizada |
Refrigeradores de água / Refrigeradores pequenos
O refrigerador pode ser amplamente utilizado em várias indústrias e laboratórios, e suporta um design personalizado.
Faixa de temperatura | -18°C ~ +30°C | Série +5°C ~ +35°C | |||||||
Capacidade de arrefecimento | 0,35 ~ 0,9kW | 1,8 ~ 50kW | |||||||
Nota: Qualquer faixa de temperatura de -150 ℃ ~ +350 ℃ e qualquer capacidade de resfriamento pode ser personalizada |
Refrigeradores de baixa temperatura
Somos especializados na produção de refrigeradores de baixa temperatura com uma gama de controlo de temperatura tão baixa como -150°C, que pode satisfazer as necessidades de refrigeração de diferentes indústrias.
Faixa de temperatura | Série -25°C ~ -5°C | Série -45°C ~ -10°C | Série -60°C ~ -10°C | Série -80°C ~ -30°C | Série -110°C ~ -50°C | Série -150°C ~ -110°C | |||
Capacidade de arrefecimento | 12 ~ 360kW | 6 ~ 180kW | 6 ~ 180kW | 4 ~ 180kW | 2 ~ 120kW | 2,5 ~ 11kW | |||
Nota: Qualquer faixa de temperatura de -150 ℃ ~ +350 ℃ e qualquer capacidade de resfriamento pode ser personalizada |
Chillers de alta temperatura
O refrigerador pode ser amplamente utilizado em várias indústrias e laboratórios, e suporta um design personalizado.
Faixa de temperatura | +5°C ~ +40°C | -25°C ~ +40°C | -45°C ~ +40°C | -80°C ~ +80°C | -100°C ~ +80°C | ||||
Capacidade de arrefecimento | 6 ~ 40kW | 2 ~ 15kW | 1 ~ 8kW | 0,6 ~ 3kW | 1,5 ~ 3kW | ||||
Nota: Qualquer faixa de temperatura de -150 ℃ ~ +350 ℃ e qualquer capacidade de resfriamento pode ser personalizada |
Chillers de arrefecimento e aquecimento
Chillers de arrefecimento e aquecimento
Gama de controlo de temperatura: -120°C a +350°C
termóstato de arrefecimento e aquecimento, amplamente utilizado em várias indústrias.
Faixa de temperatura | Série -10 ~ +150°C | Série -25 ~ +200°C | Série -25 ~ +300°C | Série -45 ~ +250°C | Série -45 ~ +300°C | Série -60 ~ +250°C | Série -60 ~ +300°C | Série -70 ~ +250°C | Série -80 ~ +250°C | Série -90 ~ +250°C | Série -100 ~ +100°C | ||
Capacidade de arrefecimento | 1,5 ~ 15kW | 1 ~ 200kW | 1 ~ 200kW | 0,45 ~ 200kW | 0,9 ~ 25kW | 0,25 ~ 60kW | 0,75 ~ 25kW | 0,4 ~ 15kW | 0,3 ~ 80kW | 0,2 ~ 80kW | 0,45 ~ 80kW | ||
Nota: Qualquer faixa de temperatura de -150 ℃ ~ +350 ℃ e qualquer capacidade de resfriamento pode ser personalizada |
Aquecedor de recirculação Chillers
Gama de controlo de temperatura: -45°C a +250°C
Faixa de temperatura | Série -25°C ~ +200°C | Série -45°C ~ +250°C | |||||||
Capacidade de arrefecimento | 1 ~ 15kW | 0,25 ~ 15kW | |||||||
Nota: Qualquer faixa de temperatura de -150 ℃ ~ +350 ℃ e qualquer capacidade de resfriamento pode ser personalizada |