With the development of science and technology and people’s increasing demand for environmental protection and energy saving, stand alone glycol heating and cooling chiller, as a new type of electromechanical equipment with high efficiency and energy saving, has gradually been widely used in industrial and commercial fields. It can provide cooling and heating functions at the same time, and achieve high-efficiency energy utilization through the cycle working principle.

Stand alone glycol heating and cooling chiller cycle process

1. Refrigeration cycle

The refrigeration cycle of a stand alone glycol heating and cooling chiller generally consists of an evaporator, a compressor, a condenser and a throttle valve. The ethylene glycol medium in the evaporator absorbs external heat, thereby cooling the air or liquid in the evaporator to achieve a cooling effect. Then, the ethylene glycol medium returned through the evaporator is compressed by the compressor, increasing its pressure and temperature. Then, the high-temperature and high-pressure ethylene glycol medium enters the condenser. Under the cooling effect of external water or air, the ethylene glycol medium dissipates heat and becomes a high-pressure liquid through the condensation process. Through the action of the throttle valve, the high-pressure liquid glycol medium enters the evaporator and restarts the next round of refrigeration process.

2. Heating cycle

The stand alone glycol heating and cooling chiller uses the evaporator in the refrigeration cycle as a heat storage device to achieve rapid storage and release of heat energy by controlling the direction and flow volume of the glycol circulating medium. When heating is required, the evaporator obtains heat energy from the outside by changing the direction of the circulating medium and stores it in the circulating medium. When heat energy needs to be released, the flow direction of the circulating medium is changed to release the stored heat energy into the object that needs to be heated.

 

Stand Alone Glycol Heating and Cooling Chiller

 

How stand alone glycol heating and cooling chiller works?

The working principle of the stand alone glycol heating and cooling chiller is based on ethylene glycol as a circulating medium, which achieves energy transfer and conversion through cyclic flow during the cooling and heating processes.

1. Working principle of refrigeration

In the refrigeration cycle, the stand alone glycol heating and cooling chiller absorbs external heat into the glycol medium through the evaporator, causing the air or liquid in the evaporator to reach a low temperature state. This is because ethylene glycol evaporates easily under low pressure and absorbs a large amount of heat during the evaporation process, causing the internal temperature of the evaporator to drop. The compressor compresses the ethylene glycol medium, causing its temperature and pressure to increase. The condenser dissipates the heat of the ethylene glycol medium through the cooling of external water or air, turning it into a high-pressure liquid. Through the action of the throttle valve, the high-pressure liquid glycol medium enters the evaporator and restarts the next round of refrigeration cycle.

2. Working principle of heating

In the heating cycle, the stand alone glycol heating and cooling chiller releases the heat stored in the evaporator to the object that needs to be heated by changing the direction and flow of the circulating medium. When heating is required, the evaporator obtains heat energy from the outside by controlling the direction of the circulating medium and stores it in the ethylene glycol circulating medium. When heat energy needs to be released, the flow direction of the circulating medium is changed, and the heat energy is released from the glycol medium to the object that needs to be heated, achieving a fast and efficient heating effect.

The stand alone glycol heating and cooling chiller can not only meet the needs of modern society for cooling and heating, but also has the characteristics of energy saving and environmental protection, making it widely used in industrial and commercial fields.

pedido

Correio eletrónico: info@lneya.com    ID WeChat: +8615251628237    WhatsApp: +86 17851209193

 


 

Sistemas de arrefecimento e aquecimento (série SUNDI)

(Desenhos personalizados)

Gama de controlo de temperatura: -120°C a +350°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Faixa de temperatura Série -10 ~ +150°C Série -25 ~ +200°C Série -25 ~ +300°C Série -45 ~ +250°C Série -45 ~ +300°C Série -60 ~ +250°C Série -60 ~ +300°C Série -70 ~ +250°C Série -80 ~ +250°CSérie -90 ~ +250°C Série -100 ~ +100°C -25 ~ +200°C uma máquina para dois reactores -40 ~ +200°C uma máquina para dois reactores
Capacidade de arrefecimento1,5 ~ 15kW1 ~ 200kW1 ~ 200kW0,45 ~ 200kW0,9 ~ 25kW0,25 ~ 60kW0,75 ~ 25kW0,4 ~ 15kW0,3 ~ 80kW0,2 ~ 80kW0,45 ~ 80kWaté 10*2kWaté 10*2kW

 


 

Sistemas de arrefecimento e aquecimento (série WTD)

(Desenhos personalizados)

(Reactores de canal micro / tubo especializados)

Gama de controlo de temperatura: -70°C a +300°C

Design especializado para micro canal (pequena capacidade de retenção de líquido, forte capacidade de troca de calor, sistema de circulação de alta queda de pressão)

 

Faixa de temperatura -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Capacidade de arrefecimento1,1 ~ 7,5kW1,5 ~ 5,5kW11 ~ 50kW

 


 

Circuladores de arrefecimento e aquecimento

(Desenhos personalizados)

Gama de controlo de temperatura: -45°C a +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Faixa de temperatura Série -25°C ~ +200°C Série -45°C ~ +250°C
Capacidade de arrefecimento1 ~ 15kW0,25 ~ 15kW

 


 

Circuladores de aquecimento

(Desenhos personalizados)

Gama de controlo de temperatura: +50°C a +300°C

Nota: A série UC pode controlar a temperatura do meio de transferência de calor. A série UST pode não só controlar a temperatura do meio de transferência de calor, mas também controlar a temperatura do material de reação.

Faixa de temperatura +50°C ~ +170°C (série UC) +50°C ~ +300°C (série UC) +50°C ~ +300°C (série UST)
Capacidade de aquecimento5,5 ~ 15kW3,5 ~ 130kW3,5 ~ 95kW

 


 

TCU Sistema de controlo da temperatura de multi-reactores

(Desenhos personalizados)

Gama de controlo de temperatura: -120°C a +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Faixa de temperatura Série -45°C ~ +250°C Série -120°C ~ +250°CSistema de controlo de temperatura personalizadoRT+10°C ~ +135°C
Capacidade de aquecimento25 ~ 80kW25 ~ 80kWPersonalizado25 ~ 300kW

Os direitos de autor pertencem a lneya-online.com, por favor contacte o email para mais informações: lilia@lneya.com

Ou digitalize o código QR do WhatsApp ou WeChat abaixo para nos contactar. 

WhatsAPP WeChat

digitalização

Anterior: Seguinte:
Últimas notícias
Pedir um orçamento
Nome
Endereço de e-mail
Telefone
Empresa
Please fill in your requirements
Pedir um orçamento

carregando...

购物车

X

我的足迹

X
palavras-chave:Alegria engarrafada refrigerador de água