Water Cooling Chiller System
The water cooling chiller system uses the shell-and-tube evaporator to exchange heat between water and the refrigerant. After the refrigerant system absorbs the heat load in the water and cools the water to produce cold water, the heat is brought to the shell-and-tube condenser by the action of the compressor. The refrigerant exchanges heat with the water, so that the water absorbs the heat and takes it out of the external cooling tower through the water pipe to dissipate it. At the beginning, the compressor sucks the low-temperature and low-pressure refrigerant gas after evaporation and refrigeration, and then compresses it into high-temperature and high-pressure gas and sends it to the condenser; After the high-pressure and high-temperature gas is cooled by the condenser, the gas is condensed into a normal-temperature and high-pressure liquid; when the normal-temperature and high-pressure liquid flows into the thermal expansion valve, it is throttled into low-temperature and low-pressure wet steam, which flows into the shell-and-tube evaporator to absorb the frozen water in the evaporator The heat lowers the water temperature; the evaporated refrigerant is sucked back into the compressor, and the cycle repeats.
The operation of the water cooling chiller system is inseparable from the water source. The better the quality of the water source, the less the range of equipment failures. Therefore, it is recommended to use high-quality water sources when using the water cooling chiller system, so as to reduce consumption and use costs, which is conducive to the long-term safe use of chillers by enterprises. The more stable the cooling performance of the water cooling chiller system is, the stricter the water source. Otherwise, various sudden failures will occur during the use of the equipment. So, what are the requirements of water cooling chiller system for water quality?
1. pH
Any water quality that is too alkaline or too acidic cannot meet the needs of industrial chillers, and even cause irreparable corrosive failures after long-term operation of industrial chillers. Therefore, when using the water cooling chiller system, high-quality water sources must be used in order to avoid a large number of equipment failures.
2. Hardness
Since the water cooling chiller system needs to use abundant water sources during operation, if the water quality is relatively hard, it will affect the operation of the chiller. Especially in the state of high-efficiency operation, it is easy to cause various scale problems inside the chiller. After the scale accumulates to a certain extent, it will affect the normal use of the chiller in the enterprise.
3. Water flow
If the water flow rate is too high or too low, it will restrict the operating efficiency of the equipment, and even lead to a decrease in the cooling performance of the chiller. Being able to continuously increase the water flow within a reasonable range can increase the safety of the operation of the chiller, and at the same time avoid problems such as affecting the operation of the chiller and causing irreparable losses due to the small water flow.
Soluções personalizadas para o seu negócio
Chillers de baixa temperatura (arrefecidos a água e a ar)
Gama de controlo de temperatura: -150°C a -5°C
Somos especializados na produção de refrigeradores de baixa temperatura com uma gama de controlo de temperatura tão baixa como -150°C, que pode satisfazer as necessidades de refrigeração de diferentes indústrias.
Faixa de temperatura | Série -25°C ~ -5°C | Série -45°C ~ -10°C | Série -60°C ~ -10°C | Série -80°C ~ -30°C | Série -110°C ~ -50°C |
Capacidade de arrefecimento | até 360kW | até 360kW | até 360kW | até 270kW | até 180kW |
Chillers de recirculação (Arrefecimento a água e ar)
Gama de controlo de temperatura: -120°C a +30°C
Nosso resfriador de recirculação adota tecnologia de refrigeração de baixa temperatura, a temperatura é tão baixa quanto -120 ℃ e vários acessórios são personalizáveis.
Faixa de temperatura | Série -25°C ~ +30°C | Série -45°C ~ +30°C | Série -60°C ~ -20°C | Série -80°C ~ -20°C | Série -120°C ~ -70°C |
Capacidade de arrefecimento | até 38kW | até 12kW | até 7,2kW | até 7,2kW | até 8,6kW |
Refrigeradores de temperatura ambiente / Refrigeradores pequenos
Gama de controlo de temperatura: +5°C a +50°C
O refrigerador pode ser amplamente utilizado em várias indústrias e laboratórios, e suporta um design personalizado.
Faixa de temperatura | -18°C ~ +30°C | Série +5°C ~ +35°C |
Capacidade de arrefecimento | até 0,9kW | até 50kW |
Equipamentos de refrigeração do tipo arrefecimento direto
Gama de controlo de temperatura: -120°C a -10°C
É adequado para locais com pequena área de troca de calor e grande troca de calor.
Faixa de temperatura | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
Potência do compressor | até 8HP | até 8HP*2 | até 45HP*3 |
Chillers de arrefecimento direto de temperatura ultra baixa
Gama de controlo de temperatura: -150°C a -110°C
Soluções personalizadas para a sua empresa.
Faixa de temperatura | -150°C ~ -110°C |
Capacidade de arrefecimento | até 11kW |
Resfriadores de parafuso
Refrigeradores de parafuso a baixa temperatura e refrigeradores de parafuso a temperatura ambiente
Soluções personalizadas para a sua empresa.
Faixa de temperatura | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Capacidade de arrefecimento | até 1027kW (Compressor único) | até 2134kW (Compressor duplo) | até 934kW (compressor único) | até 1940kW (Compressor duplo) | até 467kW (Compressor único) | até 497kW (Compressor único) |