Reactor Thermal Control Units
Reactor thermal control units help to study the internal laws and mechanisms of synthesis or reaction systems through real-time online data collection of scientific data and key process parameters, and provide theoretical basic data for process optimization, equipment amplification and intelligent controllable processing technology.
Most temperature control applications involve stainless steel and glass reactors. Stainless steel reactors are more durable, while glass reactors allow users to observe the reaction process inside the reactor body. There are many precautions to consider for the safety of your glass reactor. Typically, reactors have an internal cavity in which materials requiring temperature control are stored. The inner cavity is surrounded by a jacket that can be connected to heat transfer oil, and the temperature control system is connected to the reactor jacket. In order to control the temperature of the reactor, the thermal oil is heated and cooled in the temperature control equipment. The reactor temperature control system continuously pumps thermal oil into the reactor jacket through a circulation pump. Sudden temperature changes inside the reactor will be compensated by rapid heating and cooling of the temperature control equipment to achieve dynamic equilibrium.
To establish a reasonable scoring system, safety must be the main consideration. Any decision must be safe in many respects. In addition to operator safety, three other safety considerations must be reflected:
1. In order to ensure the implementation of the plan, the stability of the entire process is crucial.
2. Investment protection mainly has two aspects: finding ways to maintain the value of the system for a long time; maintaining expensive reactor equipment.
3. Safe operation of the entire system. Generally speaking, for a given application, a temperature control system includes three key factors: process stability, investment protection, and operational safety.
A good reactor thermal control unit must have sufficient cooling and heating power. Cooling and heating power affects how quickly the system reaches the set temperature. When calculating heating/cooling power, the user needs to consider the mass of the material, the temperature difference between the actual temperature and the set temperature, the expected cooling and heating times, and the specific heat capacity of the bath liquid.
We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.
We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.
Email: lilia@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
Cooling and Heating Systems (SUNDI series)
- Temperature range: -120℃ ~ +350℃
- High-precision, intelligent temperature control
- Cooling capacity: 0.5kW ~ 1200kW
- Fully closed system to extend the service life of thermal fluid
- Each device is load tested for more than 12 hours
Temperature range | -10 ~ +150°C series | -25 ~ +200°C series | -25 ~ +300°C series | -45 ~ +250°C series | -45 ~ +300°C series | -60 ~ +250°C series | -60 ~ +300°C series | -70 ~ +250°C series | -80 ~ +250°C series | -90 ~ +250°C series | -100 ~ +100°C series | ||
Cooling Capacity | 1.5 ~ 15kW | 1 ~ 200kW | 1 ~ 200kW | 0.45 ~ 200kW | 0.9 ~ 25kW | 0.25 ~ 60kW | 0.75 ~ 25kW | 0.4 ~ 15kW | 0.3 ~ 80kW | 0.2 ~ 80kW | 0.45 ~ 80kW | ||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Cooling and Heating Systems (WTD series)
- (Micro channel / tube reactors specialized)
- Temperature range: -70℃ ~ +300℃
- High-performance circulation pump, more stable temperature control effect
- Wide temperature range to meet the needs of more industries
- Each device is load tested for more than 12 hours
Temperature range | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C | ||||||
Cooling Capacity | 1.1 ~ 7.5kW | 1.5 ~ 5.5kW | 11 ~ 50kW | ||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Cooling and Heating Circulators
- Temperature range: -45℃ ~ +250℃
- Emerson Copeland compressor, reliable quality
- Self-diagnosis function, multiple safety protection devices
- Fully closed system to extend the service life of thermal fluid
- Each device is load tested for more than 12 hours
Temperature range | -25°C ~ +200°C series | -45°C ~ +250°C series | |||||||
Cooling Capacity | 1 ~ 15kW | 0.25 ~ 15kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Heating Circulators
- Temperature range: +50℃ ~ +300℃
- Large heat exchange area and fast heating speed
- Self-diagnosis function, multiple safety protection devices
- Closed circulation system, no oil mist at high temperatures
- Each device is load tested for more than 12 hours
Temperature range | +50°C ~ +170°C (UC series) | +50°C ~ +300°C (UC series) | +50°C ~ +300°C (UST series) | ||||||
Heating Capacity | 5.5 ~ 15kW | 3.5 ~ 130kW | 3.5 ~ 95kW | ||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
TES Series (Temperature control for fuel and oil testing)
- Temperature range: -85℃ ~ +250℃
- Siemens PLC controller and other brand accessories
- Self-diagnosis function, multiple safety protection devices
- Fully closed circulation system, no oil mist at high temperatures
- Each device is load tested for more than 12 hours
Temperature range | -45°C ~ +250°C series | -85°C ~ +200°C series | -60°C ~ +200°C series | ||||||
Cooling Capacity | 0.3 ~ 25kW | 0.25 ~ 25kW | 3 ~ 60kW | ||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
TCU Multi-reactors Temperature Control System
- Temperature range: -120℃ ~ +250℃
- Sealed, repeatable temperature control
- Built-in electric heating thermal oil auxiliary system
- Add cold and heat source heat exchange modules according to needs
- Each device is load tested for more than 12 hours
Temperature range | -45°C ~ +250°C series | -120°C ~ +250°C series | Customized Temperature Control System | RT+10°C ~ +135°C | |||||
Heating Capacity | 25 ~ 80kW | 25 ~ 80kW | Custom | 25 ~ 300kW | |||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Recirculating Chillers / Refrigerated Circulator
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -25°C ~ +30°C series | -45°C ~ +30°C series | -60°C ~ -20°C series | -80°C ~ -20°C series | -120°C ~ -70°C series | ||||
Cooling Capacity | 0.8 ~ 30kW | 0.75 ~ 12kW | 0.4 ~ 6kW | 0.2 ~ 6kW | 0.3 ~ 5kW | ||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Mini Chillers / Small Chillers
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C series | |||||||
Cooling Capacity | 0.35 ~ 0.9kW | 1.8 ~ 50kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Low Temperature Chillers
We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.
Temperature range | -25°C ~ -5°C series | -45°C ~ -10°C series | -60°C ~ -10°C series | -80°C ~ -30°C series | -110°C ~ -50°C series | -150°C ~ -110°C series | |||
Cooling Capacity | 12 ~ 360kW | 6 ~ 180kW | 6 ~ 180kW | 4 ~ 180kW | 2 ~ 120kW | 2.5 ~ 11kW | |||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
High Temperature Chillers
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | +5°C ~ +40°C | -25°C ~ +40°C | -45°C ~ +40°C | -80°C ~ +80°C | -100°C ~ +80°C | ||||
Cooling Capacity | 6 ~ 40kW | 2 ~ 15kW | 1 ~ 8kW | 0.6 ~ 3kW | 1.5 ~ 3kW | ||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |