Search Search all

Refrigerated and Heating Circulators for Jacketed Reactors

ClassificationIndustry News 47 0

Refrigerated and Heating Circulators for Jacketed Reactors

 

When choosing a refrigeration and heating circulator for a jacketed reactor, you need to consider the following aspects to ensure efficient and stable operation of the equipment:

1. Compatibility and adaptability: Confirm that the design of the circulator can perfectly connect with your jacketed reactor, including interface size, medium flow path design, etc.

2. Temperature control range and accuracy: According to your specific experimental or production needs, choose a device that covers the required temperature range (such as -80℃ to 250℃) and has high temperature control accuracy (usually ±0.1℃ to ±1℃).

 

Refrigerated and Heating Circulators for Jacketed Reactors

 

3. Refrigeration and heating capacity: Evaluate the required cooling capacity (usually kW or Btu/h) and heating power to ensure that the circulator can complete the temperature rise and fall within the required time.

4. Circulating medium: Choose a medium that is compatible with the reaction materials, non-toxic, and non-flammable, such as water or thermal oil, and consider the convenience of medium replacement and maintenance.

5. Control system: Modern circulators are usually equipped with PID automatic temperature control systems, support preset program control, remote monitoring and other functions, and improve the flexibility and safety of operation.

6. Safety features: including but not limited to over-temperature, over-pressure protection, low liquid level alarm, etc., to ensure safety during operation.

If you can provide detailed information such as the specific parameters of the jacketed reactor, such as volume, material properties, and expected temperature control range, I will be able to further provide you with personalized refrigeration and heating circulator selection recommendations.

 


 

We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.

We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.

request

Email: lilia@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 

scan

 


Cooling and Heating Systems (SUNDI series)

(Custom Designs)

  • Temperature range: -120℃ ~ +350℃
  • High-precision, intelligent temperature control
  • Cooling capacity: 0.5kW ~ 1200kW
  • Fully closed system to extend the service life of thermal fluid
  • Each device is load tested for more than 12 hours

 

Temperature range -10 ~ +150°C series -25 ~ +200°C series -25 ~ +300°C series -45 ~ +250°C series -45 ~ +300°C series -60 ~ +250°C series -60 ~ +300°C series -70 ~ +250°C series -80 ~ +250°C series-90 ~ +250°C series -100 ~ +100°C series
Cooling Capacity1.5 ~ 15kW1 ~ 200kW1 ~ 200kW0.45 ~ 200kW0.9 ~ 25kW0.25 ~ 60kW0.75 ~ 25kW0.4 ~ 15kW0.3 ~ 80kW0.2 ~ 80kW0.45 ~ 80kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


Cooling and Heating Circulators

(Custom Designs)

  • Temperature range: -45℃ ~ +250℃
  • Emerson Copeland compressor, reliable quality
  • Self-diagnosis function, multiple safety protection devices
  • Fully closed system to extend the service life of thermal fluid
  • Each device is load tested for more than 12 hours

 

Temperature range -25°C ~ +200°C series -45°C ~ +250°C series
Cooling Capacity1 ~ 15kW0.25 ~ 15kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


Cooling and Heating Systems (WTD series)

(Custom Designs)

  • (Micro channel / tube reactors specialized)
  • Temperature range: -70℃ ~ +300℃
  • High-performance circulation pump, more stable temperature control effect
  • Wide temperature range to meet the needs of more industries
  • Each device is load tested for more than 12 hours

 

Temperature range -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Cooling Capacity1.1 ~ 7.5kW1.5 ~ 5.5kW11 ~ 50kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


TCU Multi-reactors Temperature Control System

(Custom Designs)

  • Temperature range: -120℃ ~ +250℃
  • Sealed, repeatable temperature control
  • Built-in electric heating thermal oil auxiliary system
  • Add cold and heat source heat exchange modules according to needs
  • Each device is load tested for more than 12 hours

 

Temperature range -45°C ~ +250°C series -120°C ~ +250°C seriesCustomized Temperature Control SystemRT+10°C ~ +135°C
Heating Capacity25 ~ 80kW25 ~ 80kWCustom25 ~ 300kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Request a Quote
Name
Email Address
Phone
Company
Please fill in your requirements
Request A Quote

loading...

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller