How to deal with the problem of dirt and blockage in the 5tr chiller?

КлассификацияНовости индустрии 184

How to deal with the problem of dirt and blockage in the 5tr chiller?

Firstly, it is necessary to understand the reasons for the dirty and clogged FL +5°C ~ +35°C Водяные охладители. There are many reasons for the dirt and blockage problem of the 5TR cooler, mainly including the following aspects:

Accumulation of debris in the pipeline: Dirt, rust, sand and other debris in the pipeline can block the pipeline, reduce water flow, and affect the cooling effect.

Poor quality of circulating water: Impurities, precipitates, etc. in the circulating water will accumulate in the 5TR cooler, forming dirty blockage.

The interface of the inlet and outlet water pipes is not tight: If the interface of the inlet and outlet water pipes is not installed properly, it can cause water leakage or impurities to enter the outside world, forming a dirty blockage.

Secondly, it is necessary to understand how to avoid the occurrence of dirt and blockage in the 5TR cooler. To avoid the occurrence of dirt and blockage in the 5TR cooler, the following measures can be taken:

Regularly clean the pipeline: Regularly clean the dirt, rust, sand and other debris in the pipeline to ensure smooth operation.

Maintain the water quality of the circulating water: Use filters, reverse osmosis and other equipment to maintain the water quality of the circulating water, avoiding impurities, sediment, and other accumulation in the 5TR cooler.

Strengthen the sealing of pipelines: Strengthen the sealing of inlet and outlet water pipelines to ensure that they do not leak and prevent external impurities from entering the pipeline.

Regular maintenance: Regularly maintain the 5TR cooler, clean the water tank, clean the radiator, etc., to ensure the normal operation of the 5TR cooler.

When debris blockage occurs, a “filter” is generally installed in the 5TR cooler refrigeration system to filter out impurities in the system. If it is a slight blockage caused by dirty system, a slight decrease in the cooling capacity of the 5tr cooler can be felt; In severe cases, condensation or frost may occur, and it can be determined that the filter is clogged. In this case, the filter of the same model can be replaced.