Recirculating Glycol Chiller
Recirculating glycol chiller is also called low temperature constant temperature reaction bath. It is often used to cool the heating part of semiconductor manufacturing equipment: single wafer cleaning and reprinting, printing machine, automatic holder installation device, spraying device, ion plating device, etching device, single wafer processing device, slicer, packaging machine, developer Temperature management, exposure device, heating device for the magnetic part, etc. And the cooling of the heating part of the laser device: laser processing, the heating part of the fusion machine, the laser marking device, the generating device, the carbon dioxide laser processing machine, etc. play a great role.
Instructions for use of recirculating glycol chiller:
1. According to the principle of large-space refrigeration, a new and improved evaporator is adopted to reduce the temperature more quickly and the temperature is more uniform;
2. Newly designed professional circuit, PID output, more accurate temperature control;
3. The function keys all adopt touch soft keys;
4. Temperature and time digital display;
5. Make an appointment to turn on, delay to turn off;
6. With over-temperature and differential temperature alarm function;
7. Adopt air-cooled fully enclosed compressor unit, imported compressor, large cooling capacity;
8. Low-temperature experiments can be carried out in the working tank or the cold liquid in the tank can be introduced outside to cool the experimental equipment outside the machine.
Main features of recirculating glycol chiller
1. Air-cooled hermetic refrigeration compressor with fast cooling speed.
2. Microcomputer intelligent control, temperature temperature.
3. The resolution of the digital display is 0.1℃ or 0.01℃, and it has the function of correcting the deviation of the temperature measurement value.
4. Temperature over-temperature protection, automatically cut off the power supply and alarm.
5. Refrigeration system overheating and overcurrent automatic protection.
Precautions for use of recirculating glycol chiller
1. Avoid acid and alkali substances entering the tank to corrode the coil and inner tank;
2. The recirculating glycol chiller should be placed in a dry and ventilated place, with no obstacles within 300mm around the instrument;
3. Always pay attention to observe the liquid level in the tank. When the liquid level is too low, add liquid medium in time;
4. When the working temperature of the recirculating glycol chiller is low, care should be taken not to open the upper cover and keep hands away from the tank to prevent frostbite;
5. After use, all switches are turned off and the power is cut off;
6. When the liquid is circulated externally, the customer should pay special attention to the firmness of the connection of the outlet pipe to prevent it from falling off, so as to avoid liquid leakage;
7. Before using the recirculating glycol chiller, liquid medium (pure water, alcohol, antifreeze can also be used) should be added to the tank, and the liquid level of the medium should not exceed the cooling coil in the tank and be 20mm lower than the working table;
8. The instrument should be cleaned regularly. If it is not used for a long time, the medium in the tank should be emptied and wiped clean to keep the work surface and operation panel clean.
Индивидуальные решения для вашего бизнеса
Низкотемпературные чиллеры (с водяным и воздушным охлаждением)
Диапазон регулирования температуры: от -150°C до -5°C
Мы специализируемся на производстве низкотемпературных чиллеров с диапазоном регулирования температуры до -150°C, которые могут удовлетворить потребности в охлаждении различных отраслей промышленности.
Диапазон температур | Серия -25°C ~ -5°C | Серия -45°C ~ -10°C | Серия -60°C ~ -10°C | Серия -80°C ~ -30°C | Серия -110°C ~ -50°C |
Мощность охлаждения | до 360 кВт | до 360 кВт | до 360 кВт | до 270 кВт | до 180 кВт |
Рециркуляционные чиллеры (с водяным и воздушным охлаждением)
Диапазон регулирования температуры: от -120°C до +30°C
Наш рециркуляционный охладитель использует низкотемпературную технологию охлаждения, температура составляет до -120℃, а различные аксессуары могут быть настроены.
Диапазон температур | Серия -25°C ~ +30°C | Серия -45°C ~ +30°C | Серия -60°C ~ -20°C | Серия -80°C ~ -20°C | Серия -120°C ~ -70°C |
Мощность охлаждения | до 38 кВт | до 12 кВт | до 7,2 кВт | до 7,2 кВт | до 8,6 кВт |
Охладители комнатной температуры / Малые охладители
Диапазон регулирования температуры: от +5°C до +50°C
Чиллер может широко использоваться в различных отраслях промышленности и лабораториях, а также поддерживает индивидуальный дизайн.
Диапазон температур | -18°C ~ +30°C | Серия +5°C ~ +35°C |
Мощность охлаждения | до 0,9 кВт | до 50 кВт |
Холодильное оборудование прямого охлаждения
Диапазон регулирования температуры: от -120°C до -10°C
Он подходит для мест с небольшой площадью теплообмена и большим теплообменом.
Диапазон температур | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
Мощность компрессора | до 8 л.с. | до 8 л.с.*2 | до 45 л.с.*3 |
Ультранизкотемпературные чиллеры прямого охлаждения
Диапазон регулирования температуры: от -150°C до -110°C
Индивидуальные решения для вашего бизнеса.
Диапазон температур | -150°C ~ -110°C |
Мощность охлаждения | до 11 кВт |
Шнековые чиллеры
Низкотемпературные винтовые холодильники и винтовые холодильники комнатной температуры
Индивидуальные решения для вашего бизнеса.
Диапазон температур | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Мощность охлаждения | до 1027 кВт (один компрессор) | до 2134 кВт (двойной компрессор) | до 934 кВт (один компрессор) | до 1940 кВт (двойной компрессор) | до 467 кВт (один компрессор) | до 497 кВт (один компрессор) |