Temperature Control Unit Heating Cooling Systems
The role of temperature control unit heating cooling systems in environmental simulation is to simulate the changes in material properties under different temperature conditions, test the cold and heat resistance of products, and is important for improving product quality and reliability.
Environmental simulation testing is an important part of product quality assurance, and temperature control unit heating cooling systems is one of the key equipment to achieve this link.
The working principle of temperature control unit heating cooling systems mainly includes two core processes: heating and cooling. The basic structure consists of four parts: evaporator, compressor, condenser and expansion valve. When the temperature needs to be raised, the evaporator evaporates the liquid refrigerant into a vapor state, absorbs the surrounding heat, and uses an electric heater or other heating equipment to raise the temperature to the set target temperature. When the temperature needs to be lowered, the compressor compresses the vapor refrigerant, increases the pressure and temperature, and then sends it to the condenser, releases heat and condenses into a liquid state, releases the residual heat through the radiator, and completes the cycle.
By simulating various temperature conditions that may be encountered in the actual use environment, temperature control unit heating cooling systems can detect the performance of products under extreme or rapidly changing temperature conditions. This helps to discover potential design defects, material problems or deficiencies in the manufacturing process, and make timely improvements, thereby improving product quality and reliability.
Temperature control unit heating cooling systems have been widely used in many fields, including electronic components, automotive parts, building materials, plastic products, etc. For example, in the field of electronic components, it is used to test the performance of components at different temperatures, such as current carrying capacity and resistance change. In the field of automotive parts, the device is used to simulate extreme climatic conditions, test the service life of components in low temperature environments, and ensure that the car can start normally in severe cold. In the field of building materials, it is used to determine the mechanical properties of materials at different temperatures, such as tensile strength and compressive strength. And in the field of plastic products, it tests the wear resistance, corrosion resistance and aging resistance of plastics. The application of temperature control unit heating cooling systems can reduce the cost and time of field testing, while avoiding product damage and safety risks that may be caused by field testing. It saves costs for enterprises, improves production efficiency and increases economic value.
We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.
We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.
Email: lilia@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
Cooling and Heating Systems (SUNDI series)
- Temperature range: -120℃ ~ +350℃
- High-precision, intelligent temperature control
- Cooling capacity: 0.5kW ~ 1200kW
- Fully closed system to extend the service life of thermal fluid
- Each device is load tested for more than 12 hours
Temperature range | -10 ~ +150°C series | -25 ~ +200°C series | -25 ~ +300°C series | -45 ~ +250°C series | -45 ~ +300°C series | -60 ~ +250°C series | -60 ~ +300°C series | -70 ~ +250°C series | -80 ~ +250°C series | -90 ~ +250°C series | -100 ~ +100°C series | ||
Cooling Capacity | 1.5 ~ 15kW | 1 ~ 200kW | 1 ~ 200kW | 0.45 ~ 200kW | 0.9 ~ 25kW | 0.25 ~ 60kW | 0.75 ~ 25kW | 0.4 ~ 15kW | 0.3 ~ 80kW | 0.2 ~ 80kW | 0.45 ~ 80kW | ||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Cooling and Heating Systems (WTD series)
- (Micro channel / tube reactors specialized)
- Temperature range: -70℃ ~ +300℃
- High-performance circulation pump, more stable temperature control effect
- Wide temperature range to meet the needs of more industries
- Each device is load tested for more than 12 hours
Temperature range | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C | ||||||
Cooling Capacity | 1.1 ~ 7.5kW | 1.5 ~ 5.5kW | 11 ~ 50kW | ||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Cooling and Heating Circulators
- Temperature range: -45℃ ~ +250℃
- Emerson Copeland compressor, reliable quality
- Self-diagnosis function, multiple safety protection devices
- Fully closed system to extend the service life of thermal fluid
- Each device is load tested for more than 12 hours
Temperature range | -25°C ~ +200°C series | -45°C ~ +250°C series | |||||||
Cooling Capacity | 1 ~ 15kW | 0.25 ~ 15kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Heating Circulators
- Temperature range: +50℃ ~ +300℃
- Large heat exchange area and fast heating speed
- Self-diagnosis function, multiple safety protection devices
- Closed circulation system, no oil mist at high temperatures
- Each device is load tested for more than 12 hours
Temperature range | +50°C ~ +170°C (UC series) | +50°C ~ +300°C (UC series) | +50°C ~ +300°C (UST series) | ||||||
Heating Capacity | 5.5 ~ 15kW | 3.5 ~ 130kW | 3.5 ~ 95kW | ||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
TES Series (Temperature control for fuel and oil testing)
- Temperature range: -85℃ ~ +250℃
- Siemens PLC controller and other brand accessories
- Self-diagnosis function, multiple safety protection devices
- Fully closed circulation system, no oil mist at high temperatures
- Each device is load tested for more than 12 hours
Temperature range | -45°C ~ +250°C series | -85°C ~ +200°C series | -60°C ~ +200°C series | ||||||
Cooling Capacity | 0.3 ~ 25kW | 0.25 ~ 25kW | 3 ~ 60kW | ||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
TCU Multi-reactors Temperature Control System
- Temperature range: -120℃ ~ +250℃
- Sealed, repeatable temperature control
- Built-in electric heating thermal oil auxiliary system
- Add cold and heat source heat exchange modules according to needs
- Each device is load tested for more than 12 hours
Temperature range | -45°C ~ +250°C series | -120°C ~ +250°C series | Customized Temperature Control System | RT+10°C ~ +135°C | |||||
Heating Capacity | 25 ~ 80kW | 25 ~ 80kW | Custom | 25 ~ 300kW | |||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Recirculating Chillers / Refrigerated Circulator
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -25°C ~ +30°C series | -45°C ~ +30°C series | -60°C ~ -20°C series | -80°C ~ -20°C series | -120°C ~ -70°C series | ||||
Cooling Capacity | 0.8 ~ 30kW | 0.75 ~ 12kW | 0.4 ~ 6kW | 0.2 ~ 6kW | 0.3 ~ 5kW | ||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Mini Chillers / Small Chillers
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C series | |||||||
Cooling Capacity | 0.35 ~ 0.9kW | 1.8 ~ 50kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Low Temperature Chillers
We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.
Temperature range | -25°C ~ -5°C series | -45°C ~ -10°C series | -60°C ~ -10°C series | -80°C ~ -30°C series | -110°C ~ -50°C series | -150°C ~ -110°C series | |||
Cooling Capacity | 12 ~ 360kW | 6 ~ 180kW | 6 ~ 180kW | 4 ~ 180kW | 2 ~ 120kW | 2.5 ~ 11kW | |||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
High Temperature Chillers
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | +5°C ~ +40°C | -25°C ~ +40°C | -45°C ~ +40°C | -80°C ~ +80°C | -100°C ~ +80°C | ||||
Cooling Capacity | 6 ~ 40kW | 2 ~ 15kW | 1 ~ 8kW | 0.6 ~ 3kW | 1.5 ~ 3kW | ||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |