Thermal Fluid Heater means that the heat transfer oil medium reaches the required temperature after the power supply is turned on. After the temperature control of the heating equipment is carried out, the heat of the heat transfer oil is taken away by the heating equipment, and the temperature of the heat transfer oil drops, but the temperature at this time remains However, it is much higher than the normal temperature heat transfer oil, so there is no need to heat the new heat transfer oil again, only need to recycle the used heat transfer oil, and connect the heat transfer oil pipeline from the heat transfer oil outlet of the equipment to the oil heater inlet , the heat transfer oil can be recycled and reused, which reduces the electricity cost of the enterprise and saves energy.
Thermal Fluid Heater has the following advantages:
1. The device occupies a small area and can be directly installed and placed in the production workshop. It is pollution-free, quick to start, and simple and flexible to operate;
2. Higher working temperature can be obtained under lower operating pressure, up to 300°C, which reduces the pressure level of heat-consuming equipment and helps reduce equipment investment costs;
3. Closed cycle heating and cooling, small heat loss, significant energy saving effect, and can meet multiple heating equipment with different operating temperatures and multiple cooling equipment with different cooling capacity;
4. The heat transfer effect is good, the heating oil and the cooling oil are forced to circulate by the pump, which is beneficial to heat transfer, and the temperature difference between the material and the oil bath is small during the heating process;
5. The temperature control is accurate, and the temperature can be controlled within ±0.5°C.
Model | LY-5020 | LY-A020 | UC-5020 | UC-A1020 | UC-A1520 | |
Medium temperature range | +50℃~+170℃ | |||||
Temperature control | Fuzzy PID Adaptive Controller | |||||
Temperature control options | Heat transfer medium outlet temperature control | |||||
Temperature feedback | Heat transfer medium temperature feedback PT100 | |||||
Temperature Control Accuracy | ±0.5℃ | |||||
Heating power | 5.5kW | 10kW | 5.5kW | 10kW | 15kW | |
Cooling capacity | 170℃ | 5.5kW | 10kW | 15kW | ||
100℃ | 4kW | 8kW | 12kW | |||
65℃ | 1.8kW | 3.4kW | 5kW | |||
Circulation pump flow, pressure Max | 35L/min 1.5BAR | 50L/min 1.5BAR | 35L/min 1.5BAR | 50L/min 1.5BAR | 50L/min 1.5BAR | |
Heater | Flange pipe electric heater | |||||
Independent temperature limiter | Rainbow Temperature Protector | |||||
Cooler | Copper Tube Aluminum Fin Air Cooled Condenser | |||||
Operation panel | Display the set temperature and measured temperature, key operation input temperature | |||||
Security | Various safety protection functions such as overload relay and thermal protection device. | |||||
Closed circulation system | The whole system is a fully closed system, there will be no oil mist at high temperature, and no moisture in the air will be absorbed at low temperature, the system will not increase the pressure due to high temperature during operation, and the heat transfer medium will be automatically replenished at low temperature. | |||||
Connection size | ZG3/4 | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | |
Dimensions cm | 40*70*130 | 40*70*130 | 40*70*130 | 40*70*130 | 70*100*175 | |
Weight | 70kg | 80kg | 78kg | 128kg | 170kg | |
Power max AC 380V 50HZ | 5.9kW | 10.8kW | 6kW | 10.9kW | 15.7kW | |
shell material | Plastic spraying of cold-rolled sheet (standard color 7035) | |||||
Optional | Optional 7-inch color touch screen, record temperature curve, data export in excel format | |||||
Optional | SUS304 shell | |||||
Optional | Optional external touch screen controller, communication line distance 10m | |||||
Optional | Optional explosion-proof touch screen control system (ExdeIIBT4), communication line distance 15m | |||||
Optional power supply | 220V 60HZ three-phase, 440V~480V 60HZ three-phase |
Model | UC-3530 | UC-5530 | UC-7530 | UC-A1030 | UC-A1530 | UC-A2530 | UC-A3830 | UC-A6030 | UC-A9530 | UC-A13030 | |
Temperature range | 50℃~300℃ | ||||||||||
Controller | PID adaptive controller | ||||||||||
Temp. control optional | Heat-conducting medium outlet temp. control | ||||||||||
Communication protocol | MODBUS RTU protocol RS 485 interface | ||||||||||
Temperature feedback | Heat-conducting medium temperature feedback PT100 | ||||||||||
Temp. accuracy | ±0.5℃ | ||||||||||
Heating power | 3.5kW | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW | 95kW | 130kW | |
Cooling capacity | 300℃ | 3.5kW | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW | 95kW | 130kW |
200℃ | 3.5kW | 5..5kW | 7.5kW | 10kW | 13kW | 25kW | 38kW | 60kW | 95kW | 130kW | |
100℃ | 2.8kW | 4kW | 5kW | 7kW | 12kW | 20kW | 30kW | 48kW | 76kW | 100kW | |
65℃ | 1kW | 1.8kW | 2.2kW | 3kW | 5kW | 8.5kW | 12kW | 19kW | 30kW | 40kW | |
Circulation pump | Max35L/min 1.2BAR | Max35L/min 1.2BAR | Max50L/min 1.2BAR | Max50L/min 1.2BAR | Max110L/min 1.5BAR | Max150L/min 1.5BAR | Max200L/min 1.5BAR | Max250L/min 2.5BAR | Max400L/min 2.5BAR | Max400L/min 2.5BAR | |
Heater | Flanged pipe electric heater | ||||||||||
Independent temperature limiter | Lneya | ||||||||||
Cooler | Plate heat exchanger/Tube heat exchanger | ||||||||||
Operation panel | Display set temperature and measured temperature,key operation input temperature | ||||||||||
Sefety protection | Self-diagnostics;High pressure switch,overload relay、variety of security features such as thermal protection devices. | ||||||||||
Closed circulation system | The entire system is a fully enclosed system,no oil mist at high temperatures、low temperature does not absorb moisture in the air | ||||||||||
System | The system does not increase the pressure due to high temperature during operation,low temperature automatically replenishes the heat transfer medium. | ||||||||||
Connection size | ZG3/4 | ZG3/4 | ZG1 | ZG1 | ZG1 | DN32 PN10 | DN40 PN10 | DN40 PN10 | DN50 PN10 | DN50 PN10 | |
Dimensions cm | 40*70*130 | 40*70*130 | 45*70*160 | 45*70*160 | 70*100*175 | 70*100*175 | 80*100*185 | 150*100*185 | 200*145*205 | 200*145*205 | |
Weight kg | 95 | 110 | 120 | 160 | 195 | 265 | 395 | 615 | 1220 | 1400 | |
Power | 5KW | 7KW | 9KW | 12kw | 17kw | 28kw | 41kw | 65kw | 101kw | 136kw | |
Case material | Cold rolled sheet spray | ||||||||||
Optional | Optional 7-inch color touch screen,recording temperature curve,data export using excel format | ||||||||||
Optional | SUS304 shell | ||||||||||
Optional | Optional external touch screen controller,communication line distance 10m | ||||||||||
Optional | Optional explosion-proof touch screen control system(ExdeIIBT4),communication line distance 10m | ||||||||||
Optional power | 220V 60HZ three phase,440V~480V 60HZ three phase |