Water Chiller Unit
Refrigerant is indispensable in the water chiller unit. Refrigerant is one of the solvents that must be used for cooling the water chiller unit. If the refrigerant leaks, the cooling effect of the water chiller unit will decrease, and the actual cooling effect will not be achieved.
You can use soap solution, gas pressure, fluorescent light, electronic device leak detector, etc. to check for refrigerant leaks. These are very simple methods.
The water chiller unit must have enough refrigerant to work better, but the refrigerant should not be too much or not enough. Whether it is insufficient refrigerant or refrigerant leakage, it will cause harm to the water chiller unit, resulting in a continuous decrease in the overall work efficiency of industrial production. In addition, it will also cause a continuous increase in the power and energy consumption of the water chiller unit, increasing the cost and expense of the company’s application of the water chiller unit. cost.
The cause of insufficient refrigerant is leakage. Once a refrigerant leak is found, the leak location must be found immediately, and the user must always pay attention and carry out regular inspections, so that the problems of insufficient refrigerant in the water chiller unit can be eliminated in time.
Customized Solutions For Your Business
Low Temperature Chillers (Water Cooled & Air Cooled)
Temperature Control Range: -150°C to -5°C
We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.
Temperature range | -25°C ~ -5°C series | -45°C ~ -10°C series | -60°C ~ -10°C series | -80°C ~ -30°C series | -110°C ~ -50°C series |
Cooling Capacity | up to 360kW | up to 360kW | up to 360kW | up to 270kW | up to 180kW |
Recirculating Chillers (Water Cooled & Air Cooled)
Temperature Control Range: -120°C to +30°C
Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.
Temperature range | -25°C ~ +30°C series | -45°C ~ +30°C series | -60°C ~ -20°C series | -80°C ~ -20°C series | -120°C ~ -70°C series |
Cooling Capacity | up to 38kW | up to 12kW | up to 7.2kW | up to 7.2kW | up to 8.6kW |
Room Temperature Chillers / Small Chillers
Temperature Control Range: +5°C to +50°C
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C series |
Cooling Capacity | up to 0.9kW | up to 50kW |
Direct Cooling Type Refrigeration Equipments
Temperature Control Range: -120°C to -10°C
It is suitable for places with small heat exchange area and large heat exchange.
Temperature range | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
Compressor Power | up to 8HP | up to 8HP*2 | up to 45HP*3 |
Direct Cooling Ultra Low Temp Chillers
Temperature Control Range: -150°C to -110°C
Customized solutions for your business.
Temperature range | -150°C ~ -110°C |
Cooling Capacity | up to 11kW |
Screw Chillers
Low temperature screw chillers and room temperature screw chillers
Customized solutions for your business.
Temperature range | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Cooling Capacity | up to 1027kW (Single Compressor) | up to 2134kW (Dual Compressor) | up to 934kW (Single Compressor) | up to 1940kW (Dual Compressor) | up to 467kW (Single Compressor) | up to 497kW (Single Compressor) |