Search Search all

Water Cooled Refrigeration System Chillers

ClassificationIndustry News 334

Water Cooled Refrigeration System Chillers

 

The water cooled refrigeration system uses a water cooling system for heat dissipation, that is to say, it does not need to use a fan? In fact, this understanding is one-sided. According to our experience, the water cooled refrigeration system may also use a fan. In fact, most Most industrial water-cooled equipment must use fans to assist in heat dissipation. Why?

First of all, do you understand the cooling system of the water cooled refrigeration system?

The cooling system is a device for dissipating heat and cooling the condenser of the water cooled refrigeration system, and the system of this equipment cannot only have cooling water. Therefore, the water cooling system must rely on the cooling water tower to work normally, and the natural flow of the cooling water tower dissipates heat, even if there is The filler and water distribution device may also not be able to meet the heat dissipation requirements of the equipment. Therefore, it is necessary to use a fan to perform additional heat dissipation and cooling of the cooling water, or to speed up its heat dissipation and cooling effect.

Secondly, is the fan of the water cooled refrigeration system the same as the air cooling system of the air-cooled chiller?

The principle is the same, but the fan used in the cooling tower of the water-cooled chiller may not be as powerful as the fan of the air-cooled system of the air-cooled chiller, but in terms of operating principle, the two are almost the same , The cooling tower fan of the water cooled refrigeration system will often encounter problems, mainly as follows.

First, the air volume is small.

Like the air cooler, the small air volume is also one of the problems of the cooling tower fan in the water cooling system. There are many reasons for this. For example, the bearing failure mentioned below will also cause the small air volume, but the small air volume is often related to the motor. The transmission belt is related to whether the fan blade is deformed, whether there is too much dust on the fan blade, etc.

Second, bearing failure.

As long as there are fans, there will be bearing failures. The employees responsible for operating and maintaining the water cooled refrigeration system in the enterprise should regularly check the cooling tower fans, add lubricating oil regularly, and clean up possible foreign objects. If the bearings are found to be excessively worn Or if other problems cause bearing damage or operation problems, the relevant parts should be replaced in time, otherwise it will affect the heat dissipation and cooling effect of the cooling water of the cooling tower.

 

Custom Chillers                                                                                                                  

 

low temperature chiller

Low Temperature Chillers (Custom Designs)

We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series-110°C ~ -50°C series -150°C ~ -110°C series
Cooling Capacity12 ~ 360kW6 ~ 180kW6 ~ 180kW4 ~ 180kW2 ~ 120kW2.5 ~ 11kW

 


recirculating chiller

Recirculating Chillers (Custom Designs)

Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.

Temperature range -25°C ~ +30°C series -45°C ~ +30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacity0.8 ~ 30kW0.75 ~ 12kW0.4 ~ 6kW0.2 ~ 6kW0.3 ~ 5kW

 


water chiller

Room Temperature Chillers / Small Chillers (Custom Designs)

The chiller can be widely used in various industries and laboratories, and supports customized design.

Temperature range -18°C ~ +30°C +5°C ~ +35°C series
Cooling Capacity0.35 ~ 0.9kW1.8 ~ 50kW

 


Chillers for Automotive Battery Test (Custom Designs)

Temperature simulation for vehicle quality test: battery life test, fuel injector/motor test bench, airbag test, component test bench, etc.

 

Temperature range -25°C ~ +100°C -40°C ~ +100°C0°C ~ +100°C  -40°C ~ +135°C
Cooling Capacity2.8 ~ 38kW1.2 ~ 60kW1.8 ~ 60kW4 ~ 60kW

 

Temperature / Pressure / Flow can be independently controlled.

1&2: one machine for two groups control.

Temperature range -40 ~ +100℃ 1&20 ~ +100℃ 1&2
Cooling Capacity1.8kW*2 ~ 60kW*21.8kW*2 ~ 60kW*2

 

Temperature remains constant, pressure / flow can be independently controlled.

1&3: one machine for three groups control.

1&6: one machine for six groups control.

Temperature range -40 ~ +100℃ 1&2 -40 ~ +100℃ 1&3 -40 ~ +100℃ 1&6 -20 ~ +100℃ 1&6 0 ~ +100℃ 1&2 0 ~ +100℃ 1&3 0 ~ +100℃ 1&6
Cooling Capacity2.5 ~ 60kW4 ~ 60kW10 ~ 60kW10 ~ 60kW7 ~ 60kW11 ~ 60kW18 ~ 60kW

 


Semiconductor Chillers (TES series) (Custom Designs)

Suitable for precise temperature control of electronic components. In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing and other environmental testing simulations.

Temperature range -45°C ~ +250°C series -85°C ~ +200°C series -60°C ~ +200°C series
Cooling Capacity0.3 ~ 25kW0.25 ~ 25kW3 ~ 60kW

 


Semiconductor Chillers (LTS series) (Custom Designs)

Suitable for precise temperature control of electronic components. In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing and other environmental testing simulations.

Temperature range -20°C ~ +80°C series -45°C ~ +80°C series -60°C ~ +80°C series -80°C ~ +80°C series
Flow Control7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min

 


 

Chillers for Energy Storage(Custom Designs)

Liquid Cooling Solutions For Battery Energy Storage Systems

 

 

 

Temperature range -45°C ~ +55°C
Cooling Capacity45kW

 


screw-chillers

 

Screw Chillers (Custom Designs)

Low temperature screw chillers and room temperature screw chillers

 

 

Temperature range +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
Cooling Capacity107 ~ 1027kW (Single Compressor)299 ~ 2134kW (Dual Compressor)98 ~ 934kW (Single Compressor)272 ~ 1940kW (Dual Compressor)48 ~ 467kW (Single Compressor)51 ~ 497kW (Single Compressor)

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:

购物车

X

我的足迹

X